Introduction
- Services / facilities within the building include Assembly Hall, Weir Chapel, Conference Centre, minor hall, meeting rooms, visitor exhibition, Presbyterian Historical Society of Ireland.
Location
- There is a bus stop within 150m (164yds) of the venue.
- The nearest National Rail station is Great Victoria Street.
Opening Times
- Monday 09:00 - 17:00.
- Tuesday 09:00 - 17:00.
- Wednesday 09:00 - 17:00.
- Thursday 09:00 - 17:00.
- Friday 09:00 - 17:00.
- Saturday Closed.
- Sunday Closed.
Parking
- The venue does not have its own car park.
-
Public Car Parks
View
- There is a car park for public use within 200m (approx).
- The name of the car park is McCausland City Centre Car Park.
- The car park is located in Grosvenor Road.
-
On Street Blue Badge Parking
View
- On street marked Blue Badge bays are not available.
-
On Street Standard Parking
View
- Clearly signed and / or standard marked parking bays are available.
- The dimensions of the standard marked parking bays are 220cm x 450cm (7ft 3in x 14ft 9in).
- Standard marked parking bays are located in Upper Queen Street and Murray Street.
-
Drop-off Point
View
- There is not a designated drop off point.
-
Comments
View
- There are no Blue Badge bays in the car park. Parking bays are bookable and end bays are available with side access.
Outside Access (Main Entrance)
-
Entrance
View
- This information is for the entrance located at the side of the building in College Square East.
- There is ramped/sloped access at this entrance.
- The main door(s) open(s) away from you (push).
- The door(s) is/are double width.
- The width of the door opening is 340cm.
- There is a second set of doors.
- The door(s) open(s) towards you (pull).
- The door(s) is/are double width.
- The width of the door opening is 170cm.
-
Ramp/Slope
View
- The ramp/slope is located between the entrance doors.
- The gradient of the ramp/slope is slight.
- The ramp/slope is permanent.
- There is a level landing at the top of the ramp/slope.
- There is not a/are not handrail(s) at the ramp.
- The lighting levels at the ramp/slope are good.
Reception
- The desk/counter is 12m (13yd 4in) from the main entrance.
- There is level access to the desk/counter from the entrance.
- The desk/counter is low (76cm or lower).
- The lighting levels are medium.
- There is not a hearing assistance system.
Inside Access
- There is level access to the service(s).
- There is a hearing assistance system.
- The system is a fixed loop.
- Staff are trained to use the system.
- This venue does not play background music.
- Motorised scooters are welcomed in public parts of the venue.
- The lighting levels are varied.
-
Comments
View
- The conference centre and visitor exhibition are located on the ground floor.
- The Assembly Hall and meeting rooms are located on the upper levels.
- The fixed loop hearing system is located in the Assembly Hall on Level A.
Other Floors
-
Steps
View
- The floors which are accessible by stairs are G, A, 1, B, 2, 3.
- There are 15+ steps between floors.
- The steps are clearly marked.
- The steps are medium (11cm - 17cm).
- The steps do have handrails.
- The steps have a handrail on both sides.
- There is a landing.
- The lighting levels are medium.
-
Comments
View
- There is a similar staircase to the rear of the building.
Other Floors (Conference Centre)
-
Steps
View
- The floors which are accessible by stairs are G, 1.
- There are 15+ steps between floors.
- The steps are clearly marked.
- The steps are medium (11cm - 17cm).
- The steps do have handrails.
- The steps have a handrail on both sides.
- There is a landing.
- The lighting levels are bright.
Lift
- There is a lift for public use.
- The lift is located to the right as you enter.
- The lift is a standard lift.
- The floors which are accessible by this lift are G, A, 1, B, 2, 3.
- The lift is approximately 20m (21yd 2ft) from the main entrance.
- Staff do not need to be notified for use of the lift.
- The clear door width is 130cm (4ft 3in).
- The dimensions of the lift are 190cm x 210cm (6ft 3in x 6ft 11in).
- There are separate entry and exit doors in the lift.
- There is not a mirror to aid reversing out of the lift.
- The lift does have a visual floor indicator.
- The lift does have an audible announcer.
- The controls for the lift are within 90cm - 120cm from the floor.
- The lift does not have Braille markings.
- The lift does have tactile markings.
- The lighting level in the lift is medium.
Toilet with Adaptations (Dispatch Corridor)
- Accessible toilet facilities are available.
-
Location and Access
View
- The toilet is not for the sole use of disabled people.
- There is pictorial signage on or near the toilet door.
- This accessible toilet is approximately 20m (21yd 2ft) from the main entrance.
- This accessible toilet is located to the left of the conference centre, behind the reception.
- There is level access to this accessible toilet.
-
Features and Dimensions
View
- This is a shared toilet.
- A key is not required for the accessible toilet.
- The door opens outwards.
- The door is locked by a locking handle.
- The width of the accessible toilet door is 86cm (2ft 10in).
- The door is light.
- The dimensions of the accessible toilet are 147cm x 234cm (4ft 10in x 7ft 8in).
- There is not sufficient turning space in the cubicle for a wheelchair user.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the left.
- The lateral transfer space is 80cm (2ft 7in).
- There is a dropdown rail on the transfer side.
- There is a flush on the transfer side.
- The tap type is lever.
- There is a mixer tap.
- There is an emergency alarm.
- The emergency pull cord alarm is fully functional.
- Disposal facilities are available in the cubicle.
- There is a/are sanitary disposal units.
- There is a/are coat hook(s).
-
Position of Fixtures
View
- Wall mounted grab rails are available for the toilet.
- As you face the toilet the wall-mounted grab rails are on both sides.
- There is not a shelf within the accessible toilet.
- There is a mirror.
- Mirrors are not placed at a lower level or at an angle for ease of use.
- The height of the toilet seat above floor level is 48cm (1ft 7in).
- There is a hand dryer.
- The hand dryer cannot be reached from seated on the toilet.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- There is not a towel dispenser.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- There is a wash basin.
- The wash basin can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
-
Colour Contrast and Lighting
View
- The contrast between the external door and wall is good.
- There is a high colour contrast between the internal door and wall.
- The contrast between the wall-mounted grab rail(s) and wall is good.
- There is a good colour contrast between the dropdown rail(s) and wall.
- The contrast between the walls and floor is good.
- The lighting levels are medium.
Toilet with Adaptations (Conference Centre - Male)
- Accessible toilet facilities are available.
-
Location and Access
View
- The toilet is not for the sole use of disabled people.
- There is no signage on or near the toilet door.
- This accessible toilet is approximately 50m (54yd 2ft) from the main entrance.
- This accessible toilet is located to the right as you enter the conference centre on the ground floor.
- There is level access to this accessible toilet.
-
Features and Dimensions
View
- This is not a shared toilet.
- There is an accessible toilet in the female standard toilets.
- A key is not required for the accessible toilet.
- The door opens outwards.
- The door is locked by a sliding bolt.
- The width of the accessible toilet door is 75cm (2ft 6in).
- The door is light.
- The dimensions of the accessible toilet are 147cm x 220cm (4ft 10in x 7ft 3in).
- There is not sufficient turning space in the cubicle for a wheelchair user.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the right.
- The lateral transfer space is 79cm (2ft 7in).
- There is a dropdown rail on the transfer side.
- There is a flush on the transfer side.
- The tap type is lever.
- There is a mixer tap.
- There is an emergency alarm.
- The emergency pull cord alarm is fully functional.
- Disposal facilities are available in the cubicle.
- There is a/are sanitary disposal units.
- There is a/are coat hook(s).
-
Position of Fixtures
View
- Wall mounted grab rails are available for the toilet.
- As you face the toilet the wall-mounted grab rails are on both sides.
- There is not a shelf within the accessible toilet.
- There is a mirror.
- Mirrors are not placed at a lower level or at an angle for ease of use.
- The height of the toilet seat above floor level is 48cm (1ft 7in).
- There is not a hand dryer.
- There is not a towel dispenser.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- There is a wash basin.
- The wash basin can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
-
Colour Contrast and Lighting
View
- The contrast between the external door and wall is good.
- There is a high colour contrast between the internal door and wall.
- The contrast between the wall-mounted grab rail(s) and wall is fair.
- There is a fair colour contrast between the dropdown rail(s) and wall.
- The contrast between the walls and floor is good.
- The lighting levels are bright.
-
Comments
View
- The female accessible facility has the transfer space on the left.
Toilet with Adaptations (Conference Centre Kitchen Corridor)
- Accessible toilet facilities are available.
-
Location and Access
View
- The toilet is not for the sole use of disabled people.
- There is written text, tactile and pictorial signage on or near the toilet door.
- This accessible toilet is approximately 45m (49yd 8in) from the main entrance.
- This accessible toilet is located to the left as you enter the conference centre, in the corridor to the kitchen.
- There is level access to this accessible toilet.
-
Features and Dimensions
View
- This is a shared toilet.
- A key is not required for the accessible toilet.
- The door opens outwards.
- The door is locked by a locking handle.
- The width of the accessible toilet door is 86cm (2ft 10in).
- The door is heavy.
- The dimensions of the accessible toilet are 170cm x 255cm (5ft 7in x 8ft 4in).
- There is sufficient turning space in the cubicle for a wheelchair user.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the right.
- The lateral transfer space is 85cm (2ft 9in).
- There is a dropdown rail on the transfer side.
- There is a flush on the transfer side.
- The tap type is lever.
- There is a mixer tap.
- There is an emergency alarm.
- The emergency pull cord alarm is fully functional.
- Disposal facilities are available in the cubicle.
- There is a/are sanitary disposal units.
- There is not a/are not coat hook(s).
-
Position of Fixtures
View
- Wall mounted grab rails are available for the toilet.
- As you face the toilet the wall-mounted grab rails are on both sides.
- There is a shelf within the accessible toilet.
- The shelf is higher than 95cm (3ft 1in).
- There is a mirror.
- Mirrors are not placed at a lower level or at an angle for ease of use.
- The height of the toilet seat above floor level is 48cm (1ft 7in).
- There is a hand dryer.
- The hand dryer cannot be reached from seated on the toilet.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- There is not a towel dispenser.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- There is a wash basin.
- The wash basin can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
-
Colour Contrast and Lighting
View
- The contrast between the external door and wall is good.
- There is a high colour contrast between the internal door and wall.
- The contrast between the wall-mounted grab rail(s) and wall is good.
- There is a good colour contrast between the dropdown rail(s) and wall.
- The contrast between the walls and floor is good.
- The lighting levels are bright.
-
Baby Change Facilities
View
- Baby change facilities are located within the venue.
- Baby change facilities are located within the accessible toilet.
- The height of the baby change table once extended is 86cm (2ft 10in).
Standard Toilet(s)
-
Availability and Location of Standard Toilets
View
- Standard toilet facilities are available.
-
Access to Standard Shared Toilet(s)
View
- The shared toilets that were surveyed are located on the first floor.
- The shared toilet(s) is/are approximately 3m (3yd 10in) from the lift.
- Inside the venue, there is level access to the shared toilet(s).
- This is by lift.
- Lighting levels are medium.
Standard Toilet(s) (Conference Centre)
-
Availability and Location of Standard Toilets
View
- Standard toilet facilities are available.
-
Access to Standard Female and Male Toilet(s)
View
- The female and male toilet facilities that were surveyed are located to the right as you enter the conference centre.
- The female and male toilets are approximately 45m (49yd 8in) from the main entrance.
- Inside the venue, there is level access to the female and male toilets.
- Lighting levels are bright.
-
Comments
View
- There is a lowered urinal with vertical handrails in the male toilet facilities.
- The lowered urinal is 34cm from the floor.
- There are lowered wash basins in both the female and female standard toilets with vertical handrails on both sides. They are 75cm high.
Additional Info
- Staff do receive disability awareness / equality training.
- Documents are available in Braille.
- Documents are available in large print.
- A bowl of water can be provided for an assistance dog.
- A member of staff trained in BSL skills is not normally on duty.