Skip to main content

College of St Hild & St Bede - Hild Main Building

College of St Hild & St Bede, Durham, DH1 1SZ

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Service View
    • Student Support Office, Reception, Chaplains Office, Student welfare Room, Tutorial Room, Weston Computer Room, The Lord Glenamara Room, Bursars Finance and Operations Offices.
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located on the lower ground floor.
    • Female standard toilet facilities are located on the lower ground floor.
    • Male standard toilet facilities are located on the lower ground floor.
    • Gender neutral toilet facilities are located is located on the ground floor to the left as you face reception by Stair 3.

Getting Here

Useful Information

Building Parking

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by permit holders.
    • There are no parking charges that apply on the day.
    • The car park is located outside the main building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are not available.
    • The route from the car park to the building is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are level changes with no dropped kerbs.
    • The dropped kerb between the car park and the building does not have tactile paving.
    • The car park surface is tarmac.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff and visitors within approximately 200m.
    • The name of the car park is Visitors Car Park.
    • The car park is located down the hill in front of the main building.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Car Park

  • Car Park View
    • The car park is located down the hill opposite the main building.
    • The nearest building(s) to this car park is/are Hild Gym East.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is concrete.
    • Designated Blue Badge parking bays are not available.
  • Charges and Restrictions View
    • This car park can be used by permit holders and visitors.
    • There are no parking charges that apply on the day.
    • Signs are provided to give information on parking charges/restrictions.
    • Signs are clearly presented.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are not clearly signposted from this car park.
    • There is not a campus map available within the car park.

Getting Around

  • Access View
    • There is not step-free access throughout the building .
    • There is stepped access to the reception and the majority of the building via the main entrance.
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is laminate and carpet.
    • There is bench seating at regular intervals.
    • The lighting levels are moderate to good.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is consistent throughout the building.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is a hearing assistance system in the communal areas of the building.
    • The system is a fixed loop.
    • A fixed loop is located in the main reception.
    • Staff are trained to use the hearing system.
    • The hearing assistance system was tested by an AccessAble surveyor.
    • The hearing assistance system was tested on 08/06/2021.
    • The hearing loop was working at the time of testing.

Outside Access (Hild Main Entrance)

  • Entrance View
    • This information is for the entrance located to the front of the building.
    • This entrance gives access to the ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'College of St Hild and St Bede'.
    • There is stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width with a locked extension leaf.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 80cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 1 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are not between 15cm and 18cm.
    • The height of the step(s) is/are 10cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).

Outside Access (Lower Ground Floor Accessible Entrance)

  • Entrance View
    • This information is for the entrance located to the rear right of the building as you face the main entrance.
    • This entrance gives access to lower ground toilets and Joachim Room.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 90cm.
    • There is a second set of doors.
    • The door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 96cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located at the front of the entrance, between the doors and just inside of the second door.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is permanent.
    • There is not a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.
    • The width of the ramp/slope is 107cm (3ft 6in).
    • The lighting levels at the ramp/slope are moderate to good.
    • The ramp/slope does not bypass the step(s).
  • Comments View
    • To the right as enter the first set of doors there is a steep ramp with handrails on both sides to access the Joachim Room (photograph 4).

Reception (Hild Main Reception)

  • Reception View
    • The reception point is located to the top of the steps in the main building.
    • The reception point is approximately 9m (9yd 2ft) from the reception entrance.
    • Clear signage for the reception area/desk is visible from the entrance.
    • There is stepped access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are moderate to good.
    • The height of the reception counter is 115cm .
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 70cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is a clear knee recess beneath the counter.
    • The counter is staffed.
    • There is not a bell to attract attention.
    • There is a hearing assistance system at the reception point.
    • The type of system is a portable loop.
    • The hearing assistance system is signed.
    • Staff are not trained to use the hearing system.
    • The hearing assistance system was tested by an AccessAble surveyor.
    • The hearing assistance system was tested on 08/06/2021.
    • The hearing loop was working at the time of testing.
    • There is wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is laminate.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • The seats do not have armrests.
    • There is sufficient space for a wheelchair user to use the waiting area.

Step(s)

  • Stepped Level Change 1 View
    • There is a/are step(s) located ahead of you via the main entrance.
    • The step(s) is/are used to access reception (photograph 1, 2 and 3) , offices, S.C.R, Tutorial Room and Weston Computer Room.
    • There is/are 10 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.
  • Stepped Level Change 2 View
    • There is a/are step(s) located on the ground floor just past stairs 4 from the main reception.
    • The step(s) is/are used to access Weston Computer Room, Bursar and Finance office, Operations Office, The Lord Glenamara Room and stairs 5 (photograph 4, 5, 6 and 7).
    • There is/are 7 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the left going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
    • Just before these steps there is a single step which is 22cm high to access the tutorial room. There are 3 steps down and 4 steps up.
  • Stepped Level Change 3 View
    • There is a/are step(s) located to the end of corridor through the door to the right as you enter the main entrance.
    • The step(s) is/are used to access Alan Pearson Common Room, Carol Carr Reading Room, George Smith Reading Room, Post Graduate Common Room and Stair 2.
    • There is/are 11 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the left going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.
    • The handrails only cover the first 3 stairs.

Step(s) (West Side)

  • Stepped Level Change 1 View
    • There is a/are step(s) located to the end of corridor through the door to the right as you enter the main entrance.
    • The step(s) is/are used to access Alan Pearson Common Room, Carol Carr Reading Room, George Smith Reading Room, Post Graduate Common Room and Stair 2 ( Photograph 1,2 ).
    • There is/are 11 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.
    • The handrails only cover the first 3 stairs.
  • Stepped Level Change 2 View
    • There is a/are step(s) located through the double doors past the Alan Pearce Common Room and stair 2.
    • The step(s) is/are used to access Stair 2 leading to lower ground floor and corridor leading to GS RM, CC RM.
    • There is/are 4 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).
    • The lighting levels at the step(s) are low to moderate.
  • Stepped Level Change 3 View
    • There is a/are step(s) located to the end of the corridor from the last set of stairs.
    • The step(s) is/are used to access George Smith Reading Room, Carol Carr Reading Rooms.
    • There is/are 4 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are not between 15cm and 18cm.
    • The height of the step(s) is/are 19cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).
    • The lighting levels at the step(s) are low to moderate.

Other Floors (Stair 2)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located just ahead of the first set of west side stairs.
    • The stairs are approximately 3m from the first set of west side stairs.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by stairs are LG, G, 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 20cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are low to moderate.
  • Other Information View
    • The area(s) on the floors which are not accessible is/are Single door leads to accommodation on floors 1 and 2 (photograph 1, 4, 5 and 6) Double doors lead to Post Graduate Common Room on the lower ground Floor (photograph 1, 2 and 3).

Other Floors (Stair 3)

  • Stairs View
    • The stairs are located to the left of reception.
    • The stairs are approximately 10m from the reception doors.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter the stairwell on all floors.
    • The floors which are accessible by stairs are G, 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the left going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are moderate to good.
  • Other Information View
    • The area(s) on the floors which are not accessible is/are Student Accommodation is located on floor 1 and 2.

Other Floors (Stair 4)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the corridor along to the right of reception.
    • The stairs are approximately 15m from the reception lobby.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by stairs are G, LG, 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are moderate to good.
  • Other Information View
    • The area(s) on the floors which are not accessible is/are Student welfare room and student accommodation on level 1, 2 and 3.
  • Comments View
    • The stairs leading to the lower ground floor have handrails on both sides (photograph 5 and 6).

Laundry Room

  • There is a laundry room on the same corridor as the accessible toilet located to the end of the corridor, 21M from the lower ground floor accessible entrance.
  • The width of the door is 75cm wide.
  • The washers and dryers are both accessible.

Accessible Toilet(s) (Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located within the lower ground corridor.
    • This accessible toilet is approximately 15m (16yd 1ft) from the lower ground entrance.
    • There is step-free access into the accessible toilet.
    • This is a gender neutral toilet.
    • A key is not required for the accessible toilet.
    • There is written text and pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is poor.
    • The door opens outwards.
    • The door is heavy.
    • There is no lock for the toilet door.
    • The width of the accessible toilet opening is 87cm.
    • The contrast between the internal door and wall is good.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is good.
  • Toilet Features View
    • The dimensions of the accessible toilet are 265cm x 215cm (8ft 8in x 7ft 1in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 102cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 114cm (3ft 9in).
    • The transfer space is obstructed by storage items.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is poor.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is fair.
    • The contrast between the walls and floor is good.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are general waste (with no lid) and clinical waste disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is not a mirror.
    • There is not a shelf within the accessible toilet.
    • The toilet has a backrest and a cistern.
    • The height of the toilet seat above floor level is 44cm (1ft 5in).
    • The toilet seat colour contrast is poor.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 104cm (3ft 5in).
    • The contrast between the toilet roll holder and the wall is fair.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 74cm (2ft 5in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is poor.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 105cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 99cm (3ft 3in).
    • The contrast between the towel dispenser and the wall is fair.
    • There is not a hand dryer.
  • Baby Changing Facilities View
    • Baby changing facilities are located within the accessible toilet.
    • There is a fixed baby change table available .
    • The height of the baby change table is 91cm.

Standard Toilet(s)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on either side of the accessible toilet.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 18m from the lower ground entrance.
    • The colour contrast between the external toilet door(s) and wall(s) is poor.
    • There is pictorial signage on or near the toilet door.
    • It was not possible to access the female toilet.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 82cm.
    • The wash basin(s) tap type is twist/turn.
    • Lighting levels are good.