East Ayrshire Community Hospital

Ayr Road, Cumnock, East Ayrshire, KA18 1EF

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Introduction

  • Services / facilities within the building include Burnock Ward, Marchburn Ward, Pennelburn Ward, Roseburn Ward, Holmburn Ward, Day Hospital, Therapy, outpatients and X ray.
  • Comments View
    • The hospital is staffed 24 hours.
    • Visiting hours are until 20:00.

Location

  • There is a bus stop within 150m (164yds) of the venue.
  • The nearest National Rail station is Auchinleck.

Opening Hours

Parking

  • The venue does have its own car park.
  • Venue Car Park View
    • Parking is free for all users.
    • The car park type is open air/surface.
    • There is/are 10+ Blue Badge parking bay(s) within the car park.
    • The dimensions of the Blue Badge parking bay(s) are 350cm x 460cm (11ft 6in x 15ft 1in).
    • The nearest Blue Badge bay is 35m (38yd 10in) from the main entrance.
    • The furthest Blue Badge bay is 50m (54yd 2ft) from the main entrance.
    • The route from the car park to the entrance is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is/are dropped kerbs.
    • The car park surface is tarmac and block paving.
    • There is a dropped kerb between the car park and the venue.
    • The dropped kerb does not have tactile paving.
    • There is not a road to cross between the car park and the entrance.
    • The car park does not have a height restriction barrier.
  • Drop-off Point View
    • There is not a designated drop off point.

Outside Access (Main Entrance)

  • This information is for the entrance located at the front of the building.
  • There is not level access into the venue.
  • The main door(s) open(s) automatically.
  • The door(s) is / are double.
  • The width of the door opening is 197cm (6ft 6in).
  • Second set of doors View
    • There is a second set of doors.
    • The door(s) open(s) automatically.
    • The door(s) is / are double.
    • The width of the door opening is 197cm (6ft 6in).

Level Change (Main Entrance)

  • There is a ramp/slope to access this area/service.
  • The ramp/slope is located leading up to the entrance.
  • The ramp/slope gradient is slight.

Outside Access (Day Hospital Entrance)

  • This information is for the entrance located at the front of the day hospital.
  • There is level access into the venue.
  • The main door(s) open(s) automatically.
  • The door(s) is / are double.
  • The width of the door opening is 150cm (4ft 11in).
  • Second set of doors View
    • There is a second set of doors.
    • The door(s) open(s) automatically.
    • The door(s) is / are double.
    • The width of the door opening is 150cm (4ft 11in).

Reception (Outpatients Reception)

  • The desk/counter is 9m (9yd 2ft) from the main entrance.
  • There is level access to the desk/counter from the entrance.
  • The desk/counter is high (110cm+).
  • The desk/counter has a low (76cm or lower) section.
  • The lighting levels are bright.

Reception (Therapy)

  • The desk/counter is 17m (18yd 1ft) from the main entrance.
  • There is level access to the desk/counter from the entrance.
  • The desk/counter is low (76cm or lower).
  • The lighting levels are bright.
  • There is not a hearing assistance system.

Inside Access

  • There is level access to the service(s).
  • There is not a hearing assistance system.
  • This venue does not play background music.
  • Motorised scooters are welcomed in public parts of the venue.
  • The lighting levels are bright.

Restaurant Bar Internal

  • The following information is for the cafĂ©.
  • Once inside, there is level access to the service.
  • Food is available from the bar.
  • Food or drinks are ordered from the counter.
  • Food or drinks can be brought to the table.
  • No tables are permanently fixed.
  • No chairs are permanently fixed.
  • No chairs have armrests.
  • The nearest table is 8m (8yd 2ft) from the main entrance.
  • The distance between the floor and the lowest table is 73cm (2ft 5in).
  • The distance between the floor and the highest table is 73cm (2ft 5in).
  • Menus are wall only.
  • Menus are clearly written.
  • Menus are presented in contrasting colours.
  • The type of food served here is main meals and snacks.

Standard Toilet(s)

Accessible Toilet (Main Lobby)

  • Accessible toilet facilities are available.
  • Location and Access View
    • There is written text and pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the main entrance.
    • The accessible toilet is located to the left as you enter.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 90cm (2ft 11in).
    • The door is light.
    • The dimensions of the accessible toilet are 150cm x 200cm (4ft 11in x 6ft 7in).
    • There is not sufficient turning space in the cubicle for a wheelchair user.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 83cm (2ft 9in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is not a mixer tap.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are available in the cubicle.
    • There is a/are sanitary and non-infectious waste disposal units.
    • There is not a/are not coat hook(s).
  • Position of Fixtures View
    • Wall mounted grab rails are available for the toilet.
    • As you face the toilet the wall-mounted grab rails are on the left.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 45cm (1ft 6in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the external door and wall is good.
    • There is a high colour contrast between the internal door and wall.
    • The contrast between the wall-mounted grab rail(s) and wall is fair.
    • There is a fair colour contrast between the dropdown rail(s) and wall.
    • The contrast between the walls and floor is fair.
    • The lighting levels are bright.

Accessible Toilet (Outpatients)

  • Accessible toilet facilities are available.
  • Location and Access View
    • There is no signage on or near the toilet door.
    • This accessible toilet is approximately 16m (17yd 1ft) from the main entrance.
    • This accessible toilet is located ahead as you enter, in the outpatients waiting area.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is not a shared toilet.
    • The male toilet was surveyed.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 90cm (2ft 11in).
    • The door is light.
    • The dimensions of the accessible toilet are 166cm x 225cm (5ft 5in x 7ft 5in).
    • There is not sufficient turning space in the cubicle for a wheelchair user.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 154cm (5ft 1in).
    • There is a dropdown rail on the transfer side.
    • There is a flush, however it is not on the transfer side.
    • The tap type is lever.
    • There is not a mixer tap.
    • There is an emergency alarm.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are available in the cubicle.
    • There is a/are sanitary and waste paper pedal bin disposal units.
    • There is a/are coat hook(s).
  • Position of Fixtures View
    • Wall mounted grab rails are available for the toilet.
    • As you face the toilet the wall-mounted grab rails are on the right.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 42cm (1ft 5in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the external door and wall is good.
    • There is a high colour contrast between the internal door and wall.
    • The contrast between the wall-mounted grab rail(s) and wall is fair.
    • There is a fair colour contrast between the dropdown rail(s) and wall.
    • The contrast between the walls and floor is fair.
    • The lighting levels are bright.
  • Comments View
    • There is also a female accessible toilet with the lateral transfer space on the right (shown in photographs 3 and 4).

Accessible Toilet (Therapy)

  • Accessible toilet facilities are available.
  • Location and Access View
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 36m (39yd 1ft) from the main entrance.
    • This accessible toilet is located in the therapy waiting area.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 89cm (2ft 11in).
    • The door is light.
    • The dimensions of the accessible toilet are 176cm x 210cm (5ft 9in x 6ft 11in).
    • There is not sufficient turning space in the cubicle for a wheelchair user.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 106cm (3ft 6in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is not a mixer tap.
    • There is an emergency alarm.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are available in the cubicle.
    • There is a/are non-infectious waste and sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Position of Fixtures View
    • Wall mounted grab rails are available for the toilet.
    • As you face the toilet the wall-mounted grab rails are on the left.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 45cm (1ft 6in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the external door and wall is good.
    • There is a high colour contrast between the internal door and wall.
    • The contrast between the wall-mounted grab rail(s) and wall is fair.
    • There is a fair colour contrast between the dropdown rail(s) and wall.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.
  • Comments View
    • There is a similar accessible toilet here with the lateral transfer space on the left (shown in photographs 3 and 4).

Additional Info

  • Staff do receive disability awareness / equality training.
  • A member of staff trained in BSL skills is not generally on duty.
  • Staff are not Text Relay aware.