Skip to main content

White House

Harrow on the Hill Campus, Lowlands Road, Harrow, Middlesex, HA1 3AQ

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Introduction

Location

  • The venue is situated within the centre of the town.
  • This venue is situated in Harrow on the Hill.
  • The venue is not situated on a road which has a steep gradient.
  • The nearest mainline station is Harrow on the Hill.
  • There is a bus stop within 150m (164yds) of the venue.

Parking (Main)

  • The venue does have its own car park.
  • Parking is not free for all users.
  • Parking is free for Blue Badge holders.
  • Venue Car Park View
    • The car park is located to the left as you face the entrance.
    • The car park type is open air/surface.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • There is/are 4 designated parking bay(s) within the car park.
    • The dimensions of the designated parking bay(s) are 450cm x 500cm (14ft 9in x 16ft 5in).
    • Designated parking bays are clearly marked.
    • The nearest designated bay is 20m (21yd 2ft) from the main entrance.
    • The furthest designated bay is 23m (25yd 6in) from the main entrance.
    • The route from the car park to the entrance is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are slopes/ramps.
    • The car park surface is block paving.
    • There is a dropped kerb between the car park and the venue.
    • The dropped kerb does not have tactile paving.
    • The patron does not have to cross a road.
    • The car park does not have a height restriction barrier.
    • There is not a designated drop off point.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • There is ramped/sloped or stepped access at this entrance.
    • There is not a bell/buzzer.
    • There is an intercom.
    • The height of the intercom is 110cm (3ft 7in).
    • A key card is required for access at this entrance.
    • The height of the card reader/lock is 112cm (3ft 8in).
    • There is a canopy or recess which provides weather protection at this entrance.
    • The main door(s) open(s) away from you (push).
    • The door(s) is / are single.
    • The door(s) is / are heavy.
    • The width of the door opening is 107cm (3ft 6in).
  • Ramp/Slope View
    • There is a ramp/slope at this entrance.
    • The ramp/slope is located in front of the entrance.
    • The ramp/slope does bypass the step(s).
    • The ramp/slope gradient is steep.
    • The ramp is permanent.
    • There is not a level landing at the top of the ramp.
    • The ramp does have handrails.
    • The handrails are on both sides.
    • The width of the ramp is 130cm (4ft 3in).
  • Step(s) View
    • There is a / are step(s) at this entrance.
    • The step(s) is / are located to the left as you face the entrance.
    • There is / are 2 step(s) to access the entrance.
    • There is not tactile paving at the top and bottom of the step(s).
    • The step(s) is / are clearly marked.
    • The step(s) is / are deep (18cm+).
    • The steps do have handrails.
    • The handrails are on the right going up the step(s).

Inside Access

  • There is level access to the service.
  • There is a hearing assistance system.
  • The system is a portable loop.
  • Staff are trained to use the system.
  • This venue does not play background music.
  • The lighting levels are medium.
  • Comments View
    • Anyone wishing to use a motorised scooter, or charge a scooter or wheelchair whilst on college premises, needs to contact the college in advance.

Level Change (Ground Floor Corridor)

  • There is a/are step(s) to access this area/service.
  • The step(s) is/are located leading from the Armstrong to White House internal entrance to the services within the White House Building.
  • There is/are 6 step(s) to the area/service.
  • The lighting levels at the step(s) are medium.
  • The step(s) is/are clearly marked.
  • The step(s) is/are medium height (11cm - 17cm).
  • There is not a/are not handrail(s) at the step(s).
  • Comments View
    • There are no hand rails on the initial 2 steps (as shown in photograph 1)
    • There are handrails on the left hand side for the following 4 steps (as shown in photograph 2).

Other Floors

  • Steps View
    • The floors which are accessible by stairs are G-1.
    • The stairs are located ahead as you enter.
    • The stairs are approximately 6m from the main entrance.
    • There are 15+ steps between floors.
    • The lighting levels are medium.
    • The steps are clearly marked.
    • The steps are medium height (11cm - 17cm).
    • The steps do have handrails.
    • The steps have a handrail on the right going up.
    • There is a landing.
  • Other View
    • The area(s)/service(s) on the floors which are not accessible is/are additional standard toilets and offices.

Accessible Toilet(s)

  • Location and Access View
    • This accessible toilet is located to the right as you enter.
    • This accessible toilet is approximately 7m (7yd 1ft) from the main entrance.
    • There is step-free access to the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is poor.
    • The door opens inwards.
    • The door is light.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 87cm (2ft 10in).
    • The contrast between the internal door and wall is poor.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 126cm x 279cm (4ft 2in x 9ft 2in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 76cm (2ft 6in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is good.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is good.
    • The contrast between the walls and floor is fair.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is not a mirror.
    • There is not a colostomy bag shelf next to the toilet.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat colour contrast is good.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 114cm (3ft 9in).
    • The contrast between the toilet roll holder and the wall is good.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 80cm (2ft 7in).
    • There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is good.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 110cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 108cm (3ft 7in).
    • The contrast between the hand dryer and the wall is good.

Standard Shower

  • Shower facilities are available.
  • The shower(s) surveyed is/are located at the rear of the building along the corridor.
  • There is not level access to the services from the shower facilities.

Standard Toilet(s)

  • Availability and Location of Standard Toilets View
    • Standard toilet facilities are available.
    • There are unisex standard toilets facilities on all floors.
  • Access to Standard Shared Toilet(s) View
    • The shared toilets that were surveyed are located between the inside access level change steps on the ground floor corridor.
    • The shared toilet(s) is/are approximately 12m (13yd 4in) from the front entrance.
    • Inside the venue, there is not level access to the shared toilet(s).
    • Lighting levels are bright.
  • Comments View
    • There is also a standard unisex toilet located on level 1 (as shown in photograph 2) but there is no lift to access it.

Additional Info

  • Staff do receive disability awareness / equality training.
  • Staff do receive Deaf Awareness training.
  • Documents can be requested in Braille.
  • Documents can be requested in large print.
  • A member of staff trained in BSL skills is normally on duty.
  • Staff are trained to BSL level 3.