Getting Here

  • By Road View
    • Ripon Community Hospital is located west of the city centre on Firby Lane. The hospital is located on a one way system and is accessed from the city centre via Westgate.
    • There is one onsite car park. The car park is located in front of the buiding on the opposite side of Firby Lane. This is the main car park for staff and visitors.
  • By Train View
    • The nearest station to the hospital is Thirsk. Ripon Community Hospital is 10.4 miles from the train station (20 min drive).

Parking

  • Parking View
    • The venue does have a dedicated car park.
    • The car park is located opposite the building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park does not have a barrier control system.
    • The car park surface is tarmac.
    • There is a/are Blue Badge parking bay(s) available.
    • The Blue Badge bay(s) is/are clearly marked.
    • There is/are 7 designated Blue Badge parking bay(s) within the car park.
    • The dimensions of the designated Blue Badge parking bay(s) surveyed are 360cm x 600cm (11ft 10in x 19ft 8in).
    • There is a 120cm hatched zone around the Blue Badge parking bay(s).
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
  • Paying View
    • There are not parking charges for the car park.
  • Access from the Car Park View
    • The route from the car park to the entrance is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are slopes/ramps.
    • The entrance is clearly visible from the car park.
    • The surface on the approach to the entrance is tarmac, loose chippings and concrete.
    • There is no tactile paving on dropped kerbs between the car park and the entrance.
    • The nearest designated Blue Badge parking bay is approximately 65m (71yd 3in) from the main entrance.

Bus Stop(s) and Drop-off Point(s)

Outside Access (Main Entrance)

  • Entrance Details View
    • This information is for the entrance located at the front of the building.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped or stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The main door(s) open(s) automatically (away from you).
    • The main automatic door(s) is/are push pad or push button activated.
    • The push pad or push button is 90cm from floor level.
    • The door(s) is/are single width.
    • The width of the door opening is 100cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope Details View
    • The ramp/slope is located to the right of the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is not a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the left going up.
    • The width of the ramp or slope is 125cm (4ft 1in).
    • The ramp/slope does bypass the step(s).
  • Step Details View
    • The step(s) is/are located in front of the entrance.
    • There is/are 7 step(s).
    • The step(s) is/are not clearly marked.
    • There is not tactile paving at the top and bottom of the step(s).
    • The going of the step(s) is/are not between the recommended 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the left going up.

Outside Access (Martindale Wing)

  • Entrance Details View
    • This information is for the entrance located at the front of the building.
    • The entrance area/door is clearly signed.
    • There is ramped/sloped or stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 86cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) automatically.
    • The door(s) is/are single width.
    • The width of the door opening is 87cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope Details View
    • The ramp/slope is located to the left of the entrance.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is permanent.
    • There is not a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the right going up.
    • The width of the ramp or slope is 125cm (4ft 1in).
    • The ramp/slope does bypass the step(s).
  • Step Details View
    • The step(s) is/are located in front of the entrance.
    • There is/are 4 step(s).
    • The step(s) is/are not clearly marked.
    • There is not tactile paving at the top and bottom of the step(s).
    • The going of the step(s) is/are not between the recommended 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides going up.

Reception

  • Reception View
    • The reception point is located to the left as you enter.
    • The reception point is approximately 5m (5yd 1ft) from the main entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are windows, glazed screens or mirrors behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is low (76cm or lower).
    • There is sufficient space to write or sign documents on the counter.
    • There is not a clear knee recess beneath the low section of the desk.
    • The counter is staffed.
    • There is not a hearing assistance system.
    • Signs and universally accepted symbols or pictograms, indicating lifts, stairs, WCs, circulation routes and other parts of the building are provided in the reception area.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • There is not sufficient space for a wheelchair user to use the waiting area.
    • There is a mixture of seating with and without armrests.

Getting Around The Building

  • Access View
    • There is step free access throughout the building.
    • There is a steep ramp, with handrails on both sides, for access to the x-ray, ultrasound and podiatry services and accessible toilet.
    • There is a steep ramp, with no handrails, for access to staff area.
    • The width of the ramp or slope is 108cm (3ft 7in).
    • The ramp is located to the right as you exit the lift on the first floor.
    • There is a slight ramp, with no handrails, for access to the building link to the Martindale Wing.
    • The ramp is located to the left as you exit the lift on the first floor.
  • Circulation View
    • There are doors in corridors which have to be opened manually.
    • The type of flooring in walkways and corridors is carpet and vinyl.
    • There is some flooring in corridors which is shiny and could cause issues with glare or look slippery to some people.
    • Handrails with a rounded or oval profile are not provided in corridors.
    • There is good colour contrast between the walls and floor in the majority of corridors.
    • The lighting levels are varied.
    • Lighting levels of at least 100 lux at floor level, were recorded in some corridors surveyed.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is not consistent throughout the building.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in public areas.
    • There is not a hearing assistance system in the public areas of the building.
  • Comments View
    • Photograph 4 shows the slight slope leading to the Trinity Ward.

Waiting Area(s)

  • There is a/are waiting area(s) along the circulation route(s).
  • There is a mixture of seating with and without armrests.
  • There is not sufficient space for a wheelchair user to use the waiting area(s).

Other Floors

  • Stairs View
    • Signs indicating the location of the stairs are clearly visible from the entrance.
    • The floors which are accessible by stairs are G-1.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The going of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • The steps do have handrails.
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor of the building are not provided on landings.
    • The lighting levels are low.
  • Comments View
    • A single manual door is located midway up the staircase.
    • It is permanently held open during opening hours.

Lift

  • There is a lift for public use.
  • The lift is located directly ahead from the main entrance.
  • Signs indicating the location of this lift are not clearly visible from the entrance.
  • The lift is approximately 8m (8yd 2ft) from the main entrance.
  • The lift is a standard lift.
  • Staff do not need to be notified for use of the lift.
  • The floors which are accessible by this lift are G-1.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • Lighting levels are not at least 100 lux at floor level in the lift lobby.
  • The external controls for the lift are not within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is fair.
  • The colour contrast between the external lift control plate and the wall is good.
  • The clear door width is 81cm (2ft 8in).
  • The dimensions of the lift are 90cm x 205cm (2ft 11in x 6ft 9in).
  • There are not separate entry and exit doors in the lift.
  • There is not a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does not have a visual floor indicator.
  • The lift does not have an audible announcer.
  • The internal controls for the lift are not within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does not have tactile markings.
  • The lighting level in the lift is low to moderate.
  • Comments View
    • The opening to the lift has two manual sliding doors both are 81cm in width.

Accessible Toilet(s) (Ground Floor - X-Ray, Ultrasound and Podiatry Services Corridor)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • This accessible toilet is located past reception and to the left, down the ramp and to the right.
    • This accessible toilet is approximately 20m (21yd 2ft) from the main entrance.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is no signage on or near the toilet door.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The door is light.
    • The width of the accessible toilet door is 77cm (2ft 6in).
    • The dimensions of the accessible toilet are 182cm x 170cm (5ft 12in x 5ft 7in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The toilet has a non-slip floor.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 112cm (3ft 8in).
    • There is a dropdown rail on the transfer side.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • The height of the light switch/pull cord is 130cm from floor level.
    • There is an emergency alarm.
    • There is a push button alarm in the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are general domestic waste disposal units.
    • There is a flashing fire alarm beacon within the toilet.
    • There is a/are coat hook(s).
    • The height of the coat hook is 163cm from the floor.
  • Position of Fixtures View
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There are no vertical wall-mounted grab rails at the wash basin.
    • There is not a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • There is not a standard shelf within the accessible toilet.
    • There is not a colostomy changing shelf for standing users next to the toilet.
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet does not have a backrest or a cistern.
    • The height of the toilet seat above floor level is 55cm (1ft 10in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 82cm (2ft 8in).
    • There is a wash basin.
    • The wash basin cannot be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 83cm (2ft 9in).
    • The tap type is twist/turn.
    • There is not a mixer tap.
    • There is a soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 97cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 125cm (4ft 1in).
    • There is not a hand dryer.
  • Colour Contrast and Lighting View
    • The contrast between the external door and wall is good.
    • The contrast between the internal door and wall is good.
    • The contrast between the dropdown rail(s) and wall is good.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are good.
    • Lighting levels are at least 100 lux at floor level.
  • Baby Changing Facilities View
    • Baby changing facilities are located within the accessible toilet.
    • The baby change table is not set against the wall, permanently fixed at 75cm from the floor.
    • The baby change table is not height adjustable.
    • The height of the baby change table once extended is 95cm (3ft 1in).

Accessible Toilet(s) (Ground Floor - Minor Injuries Corridor)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • This accessible toilet is located past reception to the left of the staircase and then on the right of the corridor.
    • This accessible toilet is approximately 25m (27yd 1ft) from the main entrance.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The door opens inwards.
    • The push pad or push button is 77cm from floor level.
    • The door is locked by a sliding bolt.
    • The door is light.
    • The width of the accessible toilet door is 77cm (2ft 6in).
    • The dimensions of the accessible toilet are 160cm x 250cm (5ft 3in x 8ft 2in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The toilet has not got a non-slip floor.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 97cm (3ft 2in).
    • There is a dropdown rail on the transfer side.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • The height of the light switch/pull cord is 105cm from floor level.
    • There is an emergency alarm.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are available in the toilet.
    • There is a/are general domestic waste and female sanitary disposal units.
    • There is not a flashing fire alarm beacon within the toilet.
    • There is not a/are not coat hook(s).
  • Position of Fixtures View
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There are no vertical wall-mounted grab rails at the wash basin.
    • There is not a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • There is a standard shelf within the accessible toilet.
    • The shelf is not between 90cm and 100cm.
    • There is not a colostomy changing shelf for standing users next to the toilet.
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 42cm (1ft 5in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin cannot be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 80cm (2ft 7in).
    • The tap type is lever.
    • There is not a mixer tap.
    • There is a soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 110cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 112cm (3ft 8in).
    • There is not a hand dryer.
  • Colour Contrast and Lighting View
    • The contrast between the external door and wall is good.
    • The contrast between the internal door and wall is good.
    • The contrast between the dropdown rail(s) and wall is fair.
    • The contrast between the wall-mounted grab rail(s) and wall is good.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are good.
    • Lighting levels are not at least 100 lux at floor level.

Accessible Toilet(s) (Martindale Wing)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • This accessible toilet is located ahead from the Martindale Entrance and then on the right of the corridor.
    • This accessible toilet is approximately 18m (19yd 2ft) from the Martindale entrance.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The door is light.
    • The width of the accessible toilet door is 90cm (2ft 11in).
    • The dimensions of the accessible toilet are 243cm x 192cm (7ft 12in x 6ft 4in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The toilet has a non-slip floor.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 152cm (4ft 12in).
    • There is a dropdown rail on the transfer side.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • The height of the light switch/pull cord is 125cm from floor level.
    • There is an emergency alarm.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are available in the toilet.
    • There is a/are general domestic waste and female sanitary disposal units.
    • There is not a flashing fire alarm beacon within the toilet.
    • There is a/are coat hook(s).
  • Position of Fixtures View
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • There is not a standard shelf within the accessible toilet.
    • There is not a colostomy changing shelf for standing users next to the toilet.
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 43cm (1ft 5in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 95cm (3ft 1in).
    • There is a wash basin.
    • The wash basin cannot be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 73cm (2ft 5in).
    • The tap type is lever.
    • There is a mixer tap.
    • There is a soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 95cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 88cm (2ft 11in).
    • There is not a hand dryer.
  • Colour Contrast and Lighting View
    • The contrast between the external door and wall is good.
    • The contrast between the internal door and wall is good.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are good.
    • Lighting levels are at least 100 lux at floor level.

Standard Toilet(s) (First Floor)

  • Standard toilet facilities are available.
  • Access to Standard Female and Male Toilet(s) View
    • The female and male toilet facilities that were surveyed are located right as you exit the lift and then right again.
    • The female and male toilets are approximately 9m (9yd 2ft) from the lift.
    • Inside the venue, there is level access to the female and male toilets.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet with wall mounted grab rails is not available.
    • There is a vertical grab rail to the right of the seat.
    • The tap type is twist/turn.
    • There is not a flashing fire alarm beacon within the toilets.
    • Lighting levels are low to moderate.
    • Lighting levels are not at least 100 lux at floor level.