Access Guide
Location
- The venue is situated within the centre of the campus.
- This venue is situated in Stockport.
- The venue is not situated on a road which has a steep gradient.
- The nearest National Rail station is Stockport.
- There is a bus stop within 150m (164yds) of the venue.
Introduction
- Services / facilities within the building include There are four floors within the building, Teaching rooms.
Rooms and Spaces Links
Parking
- The venue does not have its own car park.
- There is not a car park for public use within 200m (approx).
- On street marked Blue Badge bays are not available.
- There is not a designated drop off point.
-
Comments
View
- The Blue Badge parking opposite the building is under construction at the moment 10/11/2021.
- The nearest Blue Badge parking is outside the main college building approximately 50 metres away.
Outside Access (Main Entrance)
-
Entrance
View
- This information is for the entrance located at the front of the building.
- There is ramped/sloped or stepped access at this entrance.
- There is a canopy or recess which provides weather protection at this entrance.
- The main door(s) open(s) automatically.
- The door(s) is / are double.
- The width of the door opening is 140cm (4ft 7in).
-
Second Set of Doors
View
- There is a second set of doors.
- The door(s) open(s) towards you (pull).
- The door(s) is / are double.
- The door(s) may be difficult to open.
- The width of the door opening is 140cm (4ft 7in).
-
Ramp/Slope
View
- There is a ramp/slope at this entrance.
- The ramp/slope is located to the left and right of the entrance.
- The ramp/slope does bypass the step(s).
- The ramp/slope gradient is slight.
- The ramp is permanent.
- There is a level landing at the top of the ramp.
-
Step(s)
View
- There is a / are step(s) at this entrance.
- The step(s) is / are located at the front of the entrance.
- There is / are 2 step(s) to access the entrance.
- There is tactile paving at the top and bottom of the step(s).
- The step(s) is / are clearly marked.
- The step(s) is / are medium height (11cm - 17cm).
- The steps do have handrails.
- The handrails are on both sides.
-
Comments
View
- The Automatic doors were out of order at the time of visit 10/11/2021.
- The doors to the left are heavy double doors that pull towards you measuring 140cm.
Location of Toilet/Changing Facilities
- Accessible toilet facilities are located on the ground floor and fourth floor.
- Female and male standard toilet facilities are located on all floors..
Getting Around
-
Access
View
- There is step free access throughout the building via lift(s).
-
Getting Around
View
- There is high colour contrast between the walls and floor in all areas.
- The lighting levels are varied.
- This building does not play background music.
- There is not a hearing assistance system.
-
Comments
View
- This building has just been painted there is no signage presently.
Link to Vernon Centre
- There are ramps that link from the Vernon Centre on the ground and first floors of the building, these are accessed by a heavy single door measuring 90cm that pulls towards you.
- The ramp on the first floor is steep.
Other Floors
-
Steps
View
- The floors which are accessible by stairs are G,1, 2, 3, 4.
- The stairs are located to the right as you enter.
- The stairs are approximately 18m from the main entrance.
- There are 15+ steps between floors.
- There are manual, double doors which may be difficult to open to access the stairwell on all floors.
- The lighting levels are moderate to good.
- The steps are clearly marked.
- The steps are medium height (11cm - 17cm).
- The steps do have handrails.
- The steps have a handrail on the left going up.
- There is a landing.
- There are similar stairs on the left side of the building.
Lift (Lift)
- There is a lift for public use.
- The lift is located at the rear of the lobby.
- The lift is a standard lift.
- The floors which are accessible by this lift are G, 1, 2, 3, 4.
- Wall mounted information boards are not provided at lift landings.
- The lift is approximately 12m (13yd 4in) from the main entrance.
- Staff do not need to be notified for use of the lift.
- The clear door width is 105cm (3ft 5in).
- The dimensions of the lift are 180cm x 195cm (5ft 11in x 6ft 5in).
- There are not separate entry and exit doors in the lift.
- There is a mirror to aid reversing out of the lift.
- The lift does have a visual floor indicator.
- The lift does have an audible announcer.
- The lift does have Braille markings.
- The lift does have tactile markings.
- The controls for the lift are within 90cm - 120cm from the floor.
- The lighting level in the lift is good.
-
Comments
View
- The lift was out of order at my time of visit 11/11/2021.
Toilet with Adaptations (Fourth Floor)
- There is an/are accessible toilet(s) available.
-
Location and Access
View
- This accessible toilet is located to the left as you exit the lift on the fourth floor.
- This accessible toilet is approximately 1m (3ft 3in) from the lift.
- There is step-free access into the accessible toilet, via lift.
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial signage on or near the toilet door.
- The contrast between the external door and wall is high.
- The door opens inwards.
- The door is easy to open.
- The door is locked by a locking handle.
- The width of the accessible toilet opening is 87cm (2ft 10in).
- The contrast between the internal door and wall is medium.
- The door has a horizontal grab rail.
- The contrast between the horizontal grab rail and internal door is high.
-
Toilet Features
View
- The dimensions of the accessible toilet are 186cm x 260cm (6ft 1in x 8ft 6in).
- The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
- The lighting levels are moderate to good.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the right.
- The lateral transfer space is 80cm (2ft 7in).
- The transfer space is obstructed by a waste disposal bin.
- There is a flush on the transfer side.
- There is a spatula type lever flush.
- There is a dropdown rail on the transfer side.
- The contrast between the dropdown rail(s) and wall is low.
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
- There is a vertical wall-mounted grab rail on the transfer side.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is high.
- The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is low.
- The contrast between the walls and floor is high.
- There is an emergency alarm.
- The emergency pull cord alarm is fully functional.
- The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
- There is not a red flashing fire alarm beacon within the toilet.
- Disposal facilities are available in the toilet.
- There is a/are sanitary and nappy/incontinence items bin disposal units.
- There is not a/are not coat hook(s).
-
Additional Fixtures
View
- There is a mirror.
- The mirror is placed at a lower level or at an angle for ease of use.
- There is not a shelf within the accessible toilet.
- The toilet has a cistern.
- The height of the toilet seat above floor level is 50cm (1ft 8in).
- The toilet seat colour contrast is high.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- The height of the toilet roll holder is 100cm (3ft 3in).
- The contrast between the toilet roll holder and the wall is low.
- There is a wash basin.
- The wash basin and tap(s) can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The height of the wash basin is 73cm (2ft 5in).
- There are vertical wall-mounted grab rails on both sides of the wash basin.
- The contrast between the wash basin wall-mounted grab rail(s) and wall is high.
- The wash basin tap type is lever mixer.
- There is a wall fixed soap dispenser.
- The soap dispenser cannot be reached from seated on the toilet.
- The height of the soap dispenser is 112cm.
- There is not a towel dispenser.
- There is a hand dryer.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- The height of the hand dryer is 98cm (3ft 3in).
- The contrast between the hand dryer and the wall is high.
Toilet with Adaptations (Ground Floor)
- There is an/are accessible toilet(s) available.
-
Location and Access
View
- This accessible toilet is located to the right as you enter the main entrance.
- This accessible toilet is approximately 2m (2yd 7in) from the main entrance.
- There is step-free access into the accessible toilet.
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial signage on or near the toilet door.
- The contrast between the external door and wall is high.
- The door opens outwards.
- The door is easy to open.
- The door is locked by a locking handle.
- The width of the accessible toilet opening is 85cm (2ft 9in).
- The contrast between the internal door and wall is high.
- The door has a horizontal grab rail.
- The contrast between the horizontal grab rail and internal door is high.
-
Toilet Features
View
- The dimensions of the accessible toilet are 137cm x 236cm (4ft 6in x 7ft 9in).
- The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
- The lighting levels are good.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the right.
- The lateral transfer space is 74cm (2ft 5in).
- The transfer space is obstructed by a waste disposal bin.
- There is a flush on the transfer side.
- There is a spatula type lever flush.
- There is a dropdown rail on the transfer side.
- The contrast between the dropdown rail(s) and wall is low.
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
- There is a vertical wall-mounted grab rail on the transfer side.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is high.
- The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is low.
- The contrast between the walls and floor is high.
- There is an emergency alarm.
- The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
- There is not a red flashing fire alarm beacon within the toilet.
- Disposal facilities are available in the toilet.
- There is a/are nappy/incontinence items bin disposal units.
- There is not a/are not coat hook(s).
-
Additional Fixtures
View
- There is a mirror.
- The mirror is placed at a lower level or at an angle for ease of use.
- There is not a shelf within the accessible toilet.
- The toilet has a cistern.
- The height of the toilet seat above floor level is 50cm (1ft 8in).
- The toilet seat colour contrast is high.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is placed higher than 100cm (3ft 3in).
- The height of the toilet roll holder is 105cm (3ft 5in).
- The contrast between the toilet roll holder and the wall is low.
- There is a wash basin.
- The wash basin and tap(s) can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The height of the wash basin is 74cm (2ft 5in).
- There are vertical wall-mounted grab rails on both sides of the wash basin.
- The contrast between the wash basin wall-mounted grab rail(s) and wall is high.
- The wash basin tap type is lever mixer.
- There is a wall fixed soap dispenser.
- The soap dispenser can be reached from seated on the toilet.
- The height of the soap dispenser is 129cm.
- There is not a towel dispenser.
- There is a hand dryer.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- The height of the hand dryer is 97cm (3ft 2in).
- The contrast between the hand dryer and the wall is high.
Standard Toilet(s)
-
Availability and Location of Standard Toilets
View
- Standard toilet facilities are available.
- There are male and female standard toilets facilities on all floors.
-
Access to Standard Female and Male Toilet(s)
View
- The female and male toilet facilities that were surveyed are located on the right hand side as you enter.
- The female and male toilets are approximately 7m (7yd 1ft) from the main entrance.
- Inside the venue, there is level access to the female and male toilets.
- Lighting levels in the female and male toilets are moderate to good.