Skip to main content
The new name for DisabledGo

Building 65 (Parkes)

University of Southampton, Avenue Campus, Southampton, SO17 1BF

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Building View
    • Services / Facilities within the building include; Level 1 - Admin, Head of School, Lecture Theatres A and C, Seminar Room, Film Studies, Lecture Theatre B, Philosophy, Security Level 2 - History and English Level U2 - Avenue Library, Centre for Language Study, ISS Work Stations, Part-time Programme Unit, Study Rooms, Seminar Room, Finance and Research Level 3 - Modern Languages.
  • Location of Toilet/Changing Facilities View
    • There is a/are Changing Places toilet(s) located on Level 2.
    • Accessible toilet facilities are located on Levels 1, 2 and 3.
    • Female standard toilet facilities are located on Levels 1, 2 and 3.
    • Male standard toilet facilities are located on Levels 1, 2 and 3.

Getting Here

  • By Road View
    • The University of Southampton Avenue Campus is located at the north of Southampton, approximately 2.5 miles from the end of the M3 (J14), along the A33. Turn left onto Highfield Road, the campus is located off of this road. The Avenue Campus is also located approximately 3 miles from Junction 4 of the M27, via Stoneham Way (A335), turning right onto Burgess Road. Just past the Highfield Campus, turn left onto the A33 and follow the directions above.
    • There is a car park on campus for staff permit holders and Blue Badge holders. Visitor parking may be available if requested in advance. There is a pay and display car park for visitors at the Highfield Campus, which is a 15 minute walk from the Avenue Campus.
    • For more information on parking at Southampton University please click here (opens new tab).
  • By Bus View
  • By Train View
    • The nearest Railway Station is St Denys Railway Station.
    • This station is approximately 1 mile from the campus which takes approximately 25 minutes to complete by foot. This station is served by the South Western Railway Service and Southern Trains. Southampton Central Railway Station is 2 miles from the campus, and is served by the South Western Railway Service, Southern Trains, Cross Country and GWR. Bus U2 can be used to access the campus from this station.
    • For more information on St Denys Railway Station please click here (opens new tab).

Building Parking

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by permit holders and Blue Badge holders.
    • There are no parking charges that apply on the day.
    • The car park is located to the side and rear of the building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 2 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) markings are faded.
    • The dimensions of the designated parking bay(s) are 360cm x 480cm.
    • The Blue Badge parking bays have a marked zone to one side but not at the rear.
    • The marked zone is 110cm wide.
    • The dimensions of the designated bays do not vary in size.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 21m (22yd 2ft) from the North Entrance.
    • The route from the car park to the building is accessible to a wheelchair user.
    • The car park surface is tarmac.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • Drop Off Point View
    • There is not a designated drop off point.
  • Comments View
    • The Blue Badge bays are accessed via the Service Entrance on the left hand side of the building.

Outside Access (South Entrance - Reception)

  • Entrance View
    • This information is for the entrance located to the right of the building.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'Building 65 Parkes'.
    • There is ramped/sloped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 112cm.
    • The main door(s) open(s) automatically (towards you).
    • The door(s) is/are double width.
    • The width of the door opening is 141cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) automatically (towards you).
    • The door(s) is/are double width.
    • The width of the door opening is 145cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located in front of the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope does not bypass the step(s).

Outside Access (East Entrance)

  • Entrance View
    • This information is for the entrance located at the rear of the building.
    • The entrance area/door is clearly signed.
    • This entrance is signed with '65 Reception'.
    • There is ramped/sloped or stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width but one door is locked.
    • The door(s) is/are heavy.
    • The width of the door opening is 73cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located in front of the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the left going up the ramp.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 4 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are in the centre of the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a second lower handrail.

Outside Access (North Entrance)

  • Entrance View
    • This information is for the entrance located to the left of the building.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically (towards you).
    • There is a push pad/button to exit the main automatic doors.
    • The entry push pad or push button is 104cm from floor level.
    • The exit push pad or push button is 118cm from floor level.
    • The door(s) is/are double width.
    • The width of the door opening is 156cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located in front of the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope does not bypass the step(s).

Outside Access (West Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 130cm.
    • The main door(s) open(s) automatically (away from you).
    • The door(s) is/are double width.
    • The width of the door opening is 145cm.
  • Comments View
    • There is an exit button which is 109cm in height.

Reception

  • Reception View
    • The reception point is located ahead from the South Entrance.
    • The reception point is approximately 4m (4yd 1ft) from the South Entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are no windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are moderate to good.
    • The height of the reception counter is 105cm.
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 75cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is a clear knee recess beneath the counter.
    • The counter is staffed.
    • There is not a hearing assistance system at the reception point.
    • There is no wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is carpet.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • There is a mixture of seating with and without armrests.
    • There is not sufficient space for a wheelchair user to use the waiting area.

Getting Around

  • Access View
    • There is step-free access throughout the building via lift(s).
    • There is sloped/ramped access to Avenue Café and Main Block.
    • There is stepped access to Avenue Café via the entrance near East Entrance.
  • Circulation View
    • There are no doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is stone and carpet.
    • There is some flooring in corridors/walkways which is shiny and could cause issues with glare or look slippery to some people.
    • Handrails with a rounded or oval profile are not provided in corridors/walkways.
    • There is low colour contrast between the walls and floor in all areas.
    • There is a mixture of seating with and without armrests at regular intervals.
    • The lighting levels are moderate to good.
  • Signage View
    • Wayfinding signage is provided.
    • Floor plans/maps are available.
    • The colour, design and typeface of signs is consistent throughout the building.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Ramp(s) or Slope(s) (Access to Main Block)

  • Ramped/Sloped Level Change 1 View
    • There is a ramp/slope located to the left of Reception.
    • The ramp/slope is used to access Main Block.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the left going up.
    • The lighting levels at the ramp/slope are good.
    • The ramp/slope does not bypass the step(s).
    • There is a standard lift to overcome the ramp(s)/slope(s).

Other Floors (Main Block)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located in the Main Block.
    • The stairs are approximately 60m from the South Entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are doors to enter/exit the stairwell on both floors.
      The door on Level 1 is a single door permanently held open with a locked leaf. The width is 116cm.
      The door on Level 2 is a double door permanently held open. The width is 145cm.
    • The floors which are accessible by the stairs are 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the right going up.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.
  • Comments View
    • There are similar stairs at the opposite end of the corridor.

Other Floors (South Block)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the right from the South Entrance.
    • The stairs are approximately 12m from the South Entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are double doors permanently held open to enter/exit the stairwell on each floor.
    • The floors which are accessible by the stairs are 1, 2, U2 and 3.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.
  • Comments View
    • There are 15+ steps between 1 and 2, 9 steps between 2 and U2 and 9 steps between U2 and 3.

Lift

  • The lift is located to the right from the South Entrance.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 10m (10yd 2ft) from the South Entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are 1, 2, U2 and 3.
  • The weight limit for the lift is 1000kg.
  • There are double doors permanently held open to access lift lobbys.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is high.
  • The colour contrast between the external lift control plate and the wall is high.
  • The clear door width is 83cm (2ft 9in).
  • The dimensions of the lift are 112cm x 212cm (3ft 8in x 6ft 11in).
  • There are separate entry and exit doors in the lift.
  • There is not a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are good.

Entrance (Avenue Café - Stepped)

  • Entrance View
    • This information is for the entrance located ahead from the East Entrance.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'AVENUE COFFEE BAR'.
    • There is stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width but one door is locked.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 61cm.
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 4 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.

Eating and Drinking (Avenue Café)

  • Location and Access View
    • The following information is for the café.
    • The café is located to the left from the South Entrance.
    • There is ramped/sloped or stepped access to the café.
    • There is an entrance from the sloped access point which has an opening of 154cm. There are no doors.
  • Service and Menus View
    • Tables cannot be booked in advance.
    • There is a counter where food and drink can be ordered.
    • Staff can bring food and/or drinks to tables.
    • Menu types include; menu boards.
    • Menus are clearly written.
    • Menus are presented in contrasting colours.
    • Staff can read menus to customers if requested.
    • The type of food served here is hot and cold meals and snacks.
    • Takeaway cups are available.
    • Adapted cups are not available.
    • Adapted cutlery is not available.
    • Drinking straws are available.
    • This area does play background music.
    • Background music is played at all times.
    • There is not a hearing assistance system .
    • There is a portable card machine available for payment.
  • Service Counter(s) View
    • The height of the counter is 90cm.
    • The height of the tray counter/rail is 78cm.
    • There is a moveable card machine available for payment.
  • Tables and Seating View
    • There is ample room for a wheelchair user to manoeuvre.
    • The majority of tables are accessible to wheelchair users.
    • The standard height for the underside of dining tables is 71cm.
    • The surface height of the lowest table is 73cm.
    • No tables are permanently fixed.
    • No chairs are permanently fixed.
    • Some chairs have armrests on both sides.
    • The type of flooring in this area is tiles and wood.
    • There is some flooring which includes patterns or colours which could be confusing or look like steps or holes to some people.
    • The lighting levels are good.
  • Comments View
    • There is a table to self serve cakes and pastries. The height is 79cm.

Toilet with Adaptations (Level 1 - South Block - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the right from the South Entrance.
    • This accessible toilet is approximately 14m (15yd 11in) from the South Entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 83cm.
    • The contrast between the internal door and wall is low.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is low.
  • Toilet Features View
    • The dimensions of the accessible toilet are 163cm x 170cm (5ft 4in x 5ft 7in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 106cm (3ft 6in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is low.
    • The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is high.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and nappy/incontinence items bin disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 113cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 70cm.
    • The shelf is not located where it is reachable.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 42cm (1ft 5in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 100cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 73cm (2ft 5in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 103cm.
    • There is a towel dispenser.
    • The towel dispenser can be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 89cm (2ft 11in).
    • The contrast between the towel dispenser and the wall is low.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 104cm (3ft 5in).
    • The contrast between the hand dryer and the wall is high.

Toilet with Adaptations (Level 2 - South Block - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the right from the lift.
    • This accessible toilet is approximately 4m (4yd 1ft) from the lift.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 86cm.
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 153cm x 166cm (5ft x 5ft 5in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 85cm (2ft 9in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is medium.
    • The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is low.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf does not have the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 84cm.
    • The shelf is not located where it is reachable.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 43cm (1ft 5in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 107cm (3ft 6in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 71cm (2ft 4in).
    • There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 108cm.
    • There is a towel dispenser.
    • The towel dispenser can be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 102cm (3ft 4in).
    • The contrast between the towel dispenser and the wall is low.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 102cm (3ft 4in).
    • The contrast between the hand dryer and the wall is high.

Changing Places (Level 2 - South Block)

  • Location and Access View
    • The facility is located to the right from the lift.
    • The facility is approximately 4m (4yd 1ft) from the lift.
    • The facility is in addition to standard and accessible toilets.
    • The facility is not located close to other managed facilities (e.g. reception or service counter).
    • There is level access into the facility.
    • The facility surveyed is not for the sole use of disabled people.
    • The colour contrast between the external door and wall is high.
    • The colour contrast between the internal door and wall is high.
    • You do not need a key for the facility.
    • There is not a sign at the entrance to the Changing Places facility indicating the location of the nearest toilets and baby changing facilities.
    • There is pictorial signage on or near the door.
    • The door opens outwards (automatically).
    • The door is light.
    • The door is locked by a lever twist.
    • The door has a horizontal grab rail.
    • The width of the door is 84cm (2ft 9in).
    • The dimensions of the facility are 280cm x 218cm.
    • The ceiling height is at a minimum of 2.4m.
    • There is not a clear 200cm x 180cm manoeuvring space in the facility.
    • The facility has a non-slip floor.
    • The colour contrast between the walls and floor is high.
  • Toilet Details View
    • The facility toilet has a transfer space on both sides.
    • The transfer space on the right as you face the toilet is 98cm (3ft 3in).
    • The transfer space on the left as you face the toilet is 70cm (2ft 4in).
    • Dropdown rails are not provided.
    • As you face the toilet the vertical grab rail is on the left.
    • The colour contrast between the wall-mounted grab rails to the left of the toilet and wall is high.
    • The height of the toilet seat above floor level is 47cm (1ft 7in).
    • There is a spatula flush.
    • There is a toilet roll holder.
    • The height of the toilet roll holder is 83cm.
    • The toilet has a wall which acts as a backrest.
    • The toilet seat colour contrast is low.
    • There is an emergency alarm for the toilet.
    • The emergency pull cord alarm is within reach and fully functional.
  • Changing Bench and Hoist Details View
    • The facility changing bench is wall mounted.
    • The facility changing bench height is adjustable.
    • The length of the facility changing bench is 155cm (5ft 1in).
    • The facility hoist is powered overhead.
    • The overhead hoist covers all areas in the cubicle.
  • Other Facilities View
    • A privacy screen is not available.
    • The type of wash basin is fixed.
    • The height of the wash basin is 72cm.
    • The wash basin tap type is lever.
    • There is a mixer tap.
    • Wall mounted grab rails are available at the wash basin.
    • As you face the wash basin, the wall mounted grab rails are on both sides.
    • The colour contrast between the wash basin grab rail(s) and wall is high.
    • There is a soap dispenser.
    • The height of the soap dispenser is 79cm.
    • Wide tear off paper roll is available.
    • The wide paper roll dispenser is at the recommended height of 80cm-100cm.
    • The height of the wide paper roll dispenser is 80cm.
    • There is a hand dryer.
    • The hand dryer is not at the recommended height of 80cm-100cm.
    • The height of the hand dryer is 110cm.
    • There is a towel dispenser.
    • The towel dispenser is not at the recommended height of 80cm-100cm.
    • The height of the towel dispenser is 104cm.
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a/are female sanitary and clinical waste disposal units.
    • There is not a shelf next to the toilet.
    • There is an emergency alarm for the facility.
    • The emergency pull cord alarm is within reach and fully functional.
    • There is not a coat hook.
    • There is a flashing fire alarm beacon within the toilet.
    • The lighting levels are good.

Toilet with Adaptations (Level 3 - South Block - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the right from the lift.
    • This accessible toilet is approximately 4m (4yd 1ft) from the lift.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is medium.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 84cm.
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 160cm x 163cm (5ft 3in x 5ft 4in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 93cm (3ft 1in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is medium.
    • The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is low.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf does not have the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 89cm.
    • The shelf is not located where it is reachable.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 42cm (1ft 5in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 94cm (3ft 1in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 74cm (2ft 5in).
    • There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 105cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 89cm (2ft 11in).
    • The contrast between the towel dispenser and the wall is low.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 104cm (3ft 5in).
    • The contrast between the hand dryer and the wall is high.

Toilet with Adaptations (North Entrance - No Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the left from the North Entrance.
    • This accessible toilet is approximately 3m (3yd 10in) from the North Entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 84cm.
    • The contrast between the internal door and wall is low.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is low.
  • Toilet Features View
    • The dimensions of the accessible toilet are 150cm x 206cm (4ft 11in x 6ft 9in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is not a lateral transfer space.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is low.
    • The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is high.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 110cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 73cm.
    • The shelf is located where it is reachable.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 43cm (1ft 5in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 100cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 75cm (2ft 6in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 92cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 105cm (3ft 5in).
    • The contrast between the towel dispenser and the wall is low.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 96cm (3ft 2in).
    • The contrast between the hand dryer and the wall is high.

Toilet with Adaptations (Main Block - Within Female Toilets - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located within the standard female toilets on the Level 1 corridor of the Main Block.
    • This accessible toilet is approximately 60m (65yd 1ft) from the South Entrance.
    • There is step-free access into the accessible toilet.
    • This is a female toilet.
    • A key is not required for the accessible toilet.
    • There is no signage on or near the toilet door.
    • The contrast between the external door and wall is low.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 89cm.
    • The contrast between the internal door and wall is low.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 142cm x 150cm (4ft 8in x 4ft 11in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 80cm (2ft 7in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is low.
    • The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is high.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is a/are coat hook(s).
    • There are coat hooks in the toilet at 138cm and 171cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf does not have the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 89cm.
    • The shelf is not located where it is reachable.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 44cm (1ft 5in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 91cm (2ft 12in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) cannot be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 76cm (2ft 6in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 108cm.
    • There is not a towel dispenser.
    • There is not a hand dryer.
  • Comments View
    • There is a similar accessible toilet within the male standard toilets in the same location.

Standard Toilet(s) (South Block)

  • Toilet Facilities View
    • The female and male toilets are located to the right from the South Entrance.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 13m from the South Entrance.
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 80cm.
    • The wash basin(s) tap type is lever.
    • Lighting levels are good.

Standard Toilet(s) (North Entrance)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located to the left from the North Entrance.
    • The standard toilet(s) is/are approximately 4m from the North Entrance.
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • It was not possible to access the male toilet.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 80cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.

Standard Toilet(s) (Main Block)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The male toilet is located to the left from the South Entrance.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 45m from the South Entrance.
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • It was not possible to access the male toilet.
  • Toilet Facilities 2 View
    • The female toilet is located to the left then right at the end of the corridor from the South Entrance.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 60m from the South Entrance.
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 80cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are moderate to good.