Access Guide
Toilet and Changing Facilities (Whipps Cross University Hospital)
-
Toilet Facilities
View
- There are 6 toilets with adaptations.
- Toilets with adaptations are located on the ground floor of the main hospital corridor.
- The transfer space varies between left and right in the toilets with adaptations.
- Ambulant toilet facilities are located on the lower ground floor (Junction 11) and on the ground floor (Junction 8).
- The male step-free toilet facilities are located on the ground floor (Junctions 3, 5 and 7).
- The shared step-free toilet facilities are located on the ground floor (Junctions 2 and 8).
-
Changing Places and Changing Facilities
View
- Parent and baby changing facilities are located in the toilets with adaptations at Junctions 2 and 3.
Toilet with Adaptations (Ground Floor - Left Hand Transfer - Junction 2)
-
Location and Access
View
- The toilet surveyed is located on the ground floor corridor by Junction 2.
- The distance from the main hospital entrance is 22m.
- The most accessible route to the toilet has step-free level access.
- There is step-free level access into the facility.
- There is pictorial and written text signage on or near the door.
- The door opens outwards and has a low visual contrast.
- The width of the door opening is 83cm.
- The door has a lever twist lock.
- Internally the door has a low visual contrast.
- There is a grab rail on the internal door with a low visual contrast.
-
Dimensions and Features
View
- The dimensions of the cubicle are 138cm (width) x 230cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
- The lateral transfer space is 70cm (from the side of the toilet pan).
- There is a lever flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There is a vertical grab rail on the transfer side.
- The vertical grab rail has a low visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a low visual contrast.
- The toilet seat is 48cm from the floor.
- The toilet seat has a high visual contrast.
- The toilet has a padded backrest.
- There is a wall mounted toilet roll holder which cannot be reached when seated on the toilet.
- The toilet roll holder has a medium visual contrast.
- The toilet roll holder is 91cm from the floor.
- The wash basin and taps can be reached when seated on the toilet.
- The wash basin is 73cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rails are on both sides of the wash basin.
- The wash basin grab rails have a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a low visual contrast.
- The soap dispenser is 97cm from the floor.
- There is a wall mounted towel dispenser which can be reached when seated on the toilet.
- The towel dispenser has a high visual contrast.
- The towel dispenser is 130cm from the floor.
- There is a wall mounted hand dryer.
- The hand dryer has a low visual contrast.
- The hand dryer is 80cm from the floor.
- There is no emergency alarm.
- There is a mirror.
- There is no shelf.
- The cubicle has a sanitary bin and a pedal bin.
- There are no coat hooks.
- The height of the baby change facility when in use is 90cm.
- The walls and floor have a high visual contrast.
- Lighting levels were even at the time of the survey.
Toilet with Adaptations (Ground Floor - Left Hand Transfer - Junction 3)
-
Location and Access
View
- The toilet surveyed is located on the ground floor corridor by Junction 3.
- The distance from the main hospital entrance is 52m.
- The most accessible route to the toilet has step-free level access and doors permanently held open.
- There is step-free level access into the facility.
- There is pictorial signage on or near the door.
- The door opens outwards and has a high visual contrast.
- The width of the door opening is 83cm.
- The door has a twist lock.
- Internally the door has a high visual contrast.
- There is not a grab rail on the internal door .
-
Dimensions and Features
View
- The dimensions of the cubicle are 144cm (width) x 235cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
- The lateral transfer space is 72cm (from the side of the toilet pan).
- There is a lever flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There is a vertical grab rail on the transfer side.
- The vertical grab rail has a high visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a high visual contrast.
- The toilet seat is 48cm from the floor.
- The toilet seat has a high visual contrast.
- The toilet has a padded backrest.
- There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
- The toilet roll holder has a high visual contrast.
- The toilet roll holder is 88cm from the floor.
- The wash basin and taps can be reached when seated on the toilet.
- The wash basin is 75cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rails are on both sides of the wash basin.
- The wash basin grab rails have a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a high visual contrast.
- The soap dispenser is 105cm from the floor.
- There is not a towel dispenser.
- There is a wall mounted hand dryer.
- The hand dryer has a high visual contrast.
- The hand dryer is 80cm from the floor.
- There is a pull cord emergency alarm, however it is not within 10cm from the floor.
- There is no mirror.
- There is no shelf.
- The cubicle has a sanitary bin and a pedal bin.
- There are no coat hooks.
- The height of the baby change facility when in use is 88cm.
- The walls and floor have a high visual contrast.
- Lighting levels were even at the time of the survey.
Toilet with Adaptations (Ground Floor - Left Hand Transfer - Junction 5)
-
Location and Access
View
- The toilet surveyed is located on the ground floor corridor by Junction 5.
- The distance from the main hospital entrance is 104m.
- The most accessible route to the toilet has step-free level access, manual doors and doors permanently held open.
- There is step-free level access into the facility.
- There is a single-width, manual door that opens away from you to enter the toilet area.
The width of this door is 87cm. - There is pictorial signage on or near the door.
- The door opens inwards and has a high visual contrast.
- The width of the door opening is 86cm.
- The door has a lever twist lock.
- Internally the door has a high visual contrast.
- There is not a grab rail on the internal door .
-
Dimensions and Features
View
- The dimensions of the cubicle are 180cm (width) x 212cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
- The lateral transfer space is 110cm (from the side of the toilet pan).
- There is a lever flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There is a vertical grab rail on the transfer side.
- The vertical grab rail has a high visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a high visual contrast.
- The toilet seat is 49cm from the floor.
- The toilet seat has a high visual contrast.
- The toilet has a padded backrest.
- There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
- The toilet roll holder has a high visual contrast.
- The toilet roll holder is 84cm from the floor.
- The wash basin and taps can be reached when seated on the toilet.
- The wash basin is 73cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rails are on both sides of the wash basin.
- The wash basin grab rails have a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a high visual contrast.
- The soap dispenser is 91cm from the floor.
- There is not a towel dispenser.
- There is a wall mounted hand dryer.
- The hand dryer has a high visual contrast.
- The hand dryer is 90cm from the floor.
- There is a pull cord emergency alarm, however it is not within 10cm from the floor.
- There is no mirror.
- There is no shelf.
- The cubicle has a pedal bin.
- There are no coat hooks.
- The walls and floor have a high visual contrast.
- Lighting levels were even at the time of the survey.
Toilet with Adaptations (Ground Floor - Right Hand Transfer - Junction 7)
-
Location and Access
View
- The toilet surveyed is located on the ground floor, by Junction 7.
- The distance from the main hospital entrance is 137m.
- The most accessible route to the toilet has step-free level access and doors permanently held open.
- There is step-free level access into the facility.
- There is pictorial signage on or near the door.
- The door opens inwards and has a high visual contrast.
- The width of the door opening is 76cm.
- The door has a twist lock.
- Internally the door has a high visual contrast.
- There is not a grab rail on the internal door .
-
Dimensions and Features
View
- The dimensions of the cubicle are 157cm (width) x 242cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
- The lateral transfer space is 82cm (from the side of the toilet pan).
- There is a spatula flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There is a vertical grab rail on the transfer side.
- The vertical grab rail has a high visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a high visual contrast.
- The toilet seat is 48cm from the floor.
- The toilet seat has a high visual contrast.
- The toilet has a padded backrest.
- There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
- The toilet roll holder has a high visual contrast.
- The toilet roll holder is 90cm from the floor.
- The wash basin and taps can be reached when seated on the toilet.
- The wash basin is 75cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rails are on both sides of the wash basin.
- The wash basin grab rails have a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a high visual contrast.
- The soap dispenser is 104cm from the floor.
- There is not a towel dispenser.
- There is a wall mounted hand dryer.
- The hand dryer has a high visual contrast.
- The hand dryer is 82cm from the floor.
- There is a pull cord emergency alarm, however it is not within 10cm from the floor.
- There is no mirror.
- There is no shelf.
- The cubicle has a sanitary bin and a pedal bin.
- There are no coat hooks.
- The walls and floor have a high visual contrast.
- Lighting levels were even at the time of the survey.
Toilet with Adaptations (Ground Floor - Left Hand Transfer - Junction 8)
-
Location and Access
View
- The toilet surveyed is located on the ground floor corridor, by Junction 8.
- The distance from the main hospital entrance is 174m.
- The most accessible route to the toilet has step-free level access and doors permanently held open.
- There is step-free level access into the facility.
- There is pictorial signage on or near the door.
- The door opens inwards and has a high visual contrast.
- The width of the door opening is 87cm.
- The door has a twist lock.
- Internally the door has a high visual contrast.
- There is not a grab rail on the internal door .
-
Dimensions and Features
View
- The dimensions of the cubicle are 186cm (width) x 176cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
- The lateral transfer space is 107cm (from the side of the toilet pan).
- There is a spatula flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There is a vertical grab rail on the transfer side.
- The vertical grab rail has a high visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a high visual contrast.
- The toilet seat is 48cm from the floor.
- The toilet seat has a high visual contrast.
- There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
- The toilet roll holder has a high visual contrast.
- The toilet roll holder is 92cm from the floor.
- The wash basin and taps can be reached when seated on the toilet.
- The wash basin is 74cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rails are on both sides of the wash basin.
- The wash basin grab rails have a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a high visual contrast.
- The soap dispenser is 107cm from the floor.
- There is not a towel dispenser.
- There is a wall mounted hand dryer.
- The hand dryer has a high visual contrast.
- The hand dryer is 97cm from the floor.
- There is a pull cord emergency alarm, however it is not within 10cm from the floor.
- There is no mirror.
- There is no shelf.
- The cubicle has a sanitary bin and a pedal bin.
- There are no coat hooks.
- The walls and floor have a high visual contrast.
- Lighting levels were even at the time of the survey.
Toilet with Adaptations (Ground Floor - Left Hand Transfer - Junction 11)
-
Location and Access
View
- The toilet surveyed is located on the ground floor by Junction 11.
- The distance from the main hospital entrance is 230m.
- The most accessible route to the toilet has step-free level access and doors permanently held open.
- There is step-free level access into the facility.
- There is pictorial signage on or near the door.
- The door opens inwards and has a high visual contrast.
- The width of the door opening is 83cm.
- The door has a twist lock.
- Internally the door has a high visual contrast.
- There is a grab rail on the internal door with a high visual contrast.
-
Dimensions and Features
View
- The dimensions of the cubicle are 173cm (width) x 280cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
- There is a lateral transfer space to the left as you face the toilet.
- The lateral transfer space is 107cm (from the side of the toilet pan).
- There is a lever flush on the transfer side.
- There is a horizontal grab rail on the non-transfer side.
- The horizontal grab rail has a high visual contrast.
- There is a vertical grab rail on the transfer side.
- The vertical grab rail has a high visual contrast.
- There is a dropdown rail on the transfer side.
- The dropdown rail has a high visual contrast.
- The toilet seat is 48cm from the floor.
- The toilet seat has a high visual contrast.
- The toilet has a padded backrest.
- There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
- The toilet roll holder has a high visual contrast.
- The toilet roll holder is 87cm from the floor.
- The wash basin and taps can be reached when seated on the toilet.
- The wash basin is 75cm from the floor.
- The wash basin has a lever mixer tap.
- The vertical grab rails are on both sides of the wash basin.
- The wash basin grab rails have a high visual contrast.
- There is a wall mounted soap dispenser which can be reached when seated on the toilet.
- The soap dispenser has a high visual contrast.
- The soap dispenser is 91cm from the floor.
- There is not a towel dispenser.
- There is a wall mounted hand dryer.
- The hand dryer has a high visual contrast.
- The hand dryer is 80cm from the floor.
- There is a pull cord emergency alarm, however it is not within 10cm from the floor.
- There is no mirror.
- There is no shelf.
- The cubicle has a sanitary bin and a pedal bin.
- There are no coat hooks.
- The walls and floor have a high visual contrast.
- Lighting levels were even at the time of the survey, with unshaded light sources.
