Public Toilets

  • Location and Access to Toilets View
    • These facilities are located on the outer wall of another venue, with separate access for each toilet.
    • The facilities are located in the lane between High Street and Church Street at Market Hall.
    • The type of toilet facilities located here are; accessible toilet(s) and female and male standard toilets.
    • There is ramped/sloped access to the accessible toilet facilities.
    • There is ramped/sloped and stepped access to the female and male standard toilets.
    • The access to toilets is via; manual door(s).
    • There is not a charge for use of the toilet(s).
  • Parking View
    • The toilet block is located next to a public car park.
    • Blue Badge parking is not available.
  • Additional Information View
    • The toilets are not staffed.

Accessible Toilet(s)

  • There is an/are accessible toilet(s) for public use.
  • The accessible toilet surveyed is for the sole use of disabled people.
  • This accessible toilet is located at the top of the lane, near the car park.
  • There is ramped/sloped access to the accessible toilet.
  • This is a shared toilet.
  • A key is required for the accessible toilet.
  • The key is a radar key.
  • There is pictorial signage on or near the toilet door.
  • The door opens outwards.
  • The door is light.
  • The door is locked by a twist lock.
  • The width of the accessible toilet door is 95cm (3ft 1in).
  • The door has a horizontal grab rail.
  • The dimensions of the accessible toilet are 131cm x 301cm (4ft 4in x 9ft 11in).
  • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
  • The toilet has a non-slip floor.
  • There is a lateral transfer space.
  • As you face the toilet pan the transfer space is on the left.
  • The lateral transfer space is 69cm (2ft 3in).
  • The transfer space is obstructed by a female sanitary waste bin and a general domestic waste bin.
  • There is a flush, however it is not on the transfer side.
  • There is not a spatula type lever flush.
  • There is a dropdown rail on the transfer side.
  • There is an emergency alarm.
  • There is a flashing fire alarm beacon within the toilet.
  • Disposal facilities are available in the toilet.
  • There is a/are female sanitary and general domestic waste disposal units.
  • There is not a/are not coat hook(s).
  • There is a/are wall-mounted grab rail(s) available.
  • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
  • There is a vertical wall-mounted grab rail on the transfer side.
  • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
  • There is not a mirror.
  • There is not a shelf next to the toilet.
  • The toilet has a cistern.
  • The height of the toilet seat above floor level is 47cm (1ft 7in).
  • There is a toilet roll holder.
  • The toilet roll holder can be reached from seated on the toilet.
  • The toilet roll holder is not placed higher than 100cm (3ft 3in).
  • There is a wash basin.
  • The wash basin can be reached from seated on the toilet.
  • The wash basin is not placed higher than 74cm (2ft 5in).
  • There are vertical wall-mounted grab rails on both sides of the wash basin.
  • The wash basin tap type is lever.
  • There is a mixer tap.
  • Taps do not have clear markings to indicate hot and cold settings.
  • There is a soap dispenser.
  • The soap dispenser can be reached from seated on the toilet.
  • The height of the soap dispenser is 113cm.
  • There is not a towel dispenser.
  • There is a hand dryer.
  • The hand dryer cannot be reached from seated on the toilet.
  • The hand dryer is placed higher than 100cm (3ft 3in).
  • The height of the hand dryer is 114cm (3ft 9in).
  • The contrast between the external door and wall is good.
  • The contrast between the internal door and wall is poor.
  • The contrast between the dropdown rail(s) and wall is good.
  • The contrast between the wall-mounted grab rail(s) and wall is good.
  • The toilet seat colour contrast is good.
  • The contrast between the walls and floor is good.
  • The lighting levels are moderate to good.
  • Baby Changing Facilities View
    • Baby changing facilities are located within the accessible toilet.
    • The baby change table is not set against the wall, permanently fixed at 75cm from the floor.
    • The baby change table is not height adjustable.
    • The height of the baby change table once extended is 99cm (3ft 3in).

Access To (Accessible Toilet)

  • Ramp/Slope View
    • The ramp/slope leads up from the High Street to the toilet doorway.
      If approaching from Church Street, there is no ramp/slope.
    • The gradient of the ramp/slope is slight.

Standard Toilet(s)

  • Toilet Facilities View
    • The male toilet is located off the lane, the door nearest High Street.
    • There is ramped/sloped and stepped access to the toilet(s).
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial and written text signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 82cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are moderate to good.
  • Toilet Facilities 2 View
    • The female toilet is located off the lane, the door in the middle.
    • There is ramped/sloped and stepped access to the toilet(s).
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial and written text signage on or near the toilet door.
    • It was not possible to access the female toilet.

Access To (Male Toilets)

  • Ramp/Slope View
    • The ramp/slope leads past the male toilets.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope does not bypass the step(s).
  • Stairs View
    • The step is in the male toilets doorway.
    • There are 1 steps .
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The steps are not clearly marked.
    • There is not a/are not handrail(s) at the step(s).

Access To (Female Toilets)

  • Ramp/Slope View
    • The ramp/slope leads past the female toilets door.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope does not bypass the step(s).
  • Stairs View
    • The step is in the female toilets doorway.
    • There are 1 steps .
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The steps are not clearly marked.
    • There is not a/are not handrail(s) at the step(s).