Outside Access (Front Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'NORTH BLOCK 3'.
    • There is ramped/sloped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width with a locked extension leaf.
    • The door(s) is/are heavy.
    • The width of the door opening is 71cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The exit push pad or push button is 120cm from floor level.
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 152cm.
    • A key card is required to pass through the security barriers.
    • The height of the key card reader is 119cm.
  • Ramp/Slope View
    • The ramp/slope is located in front of the entrance.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.

Other Floors

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located at the front of the building, to the left as you enter via the front entrance.
    • The stairs are approximately 4m from the front entrance.
    • The stairs are clearly visible from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by the stairs are The ground and first floor.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 15cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 29cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a second lower handrail.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are varied.
  • Comments View
    • There is a similar staircase located at the rear of the building.

Entrance

  • Entrance View
    • This information is for the entrance located on Level 1 of North Block 3, off the main walkways.
    • This entrance gives access to the Theatre.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'The Studio THEATRE'.
    • There is ramped/sloped or stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • There are no doors at this entrance.
    • The door(s) is/are single width.
    • The width of the door opening is 127cm.
  • Ramp/Slope View
    • The ramp/slope is located in front of the entrance.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is portable.
    • There is a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.
    • The width of the ramp/slope is 79cm (2ft 7in).
    • The lighting levels at the ramp/slope are moderate to good.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 2 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).
    • The lighting levels at the step(s) are moderate to good.

Theatre Information

Theatre Seating Area(s)

  • Access to Seating View
    • The information below describes access to the Stalls.
    • The theatre area is located on Level 1 of the North Block 3.
    • There is stepped access to the theatre area.
    • The entrance area/door is not clearly signed.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are single width with a locked extension leaf.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 65cm.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are single width with a locked extension leaf.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 64cm.
    • All doors accessing the area are similar.
    • The doors is/are permanently held open before and after performances.
    • There is a member of staff available for assistance at the doors before and after performances.
    • The doors give access to The top row.
  • Theatre Area Information View
    • This information refers to the Stalls.
    • The type of flooring in the seating area is carpet.
    • There are flip-down seats with armrests on both sides.
    • The width of the rows of seating is 45cm.
    • The lighting level before and after performances is low to moderate.
    • There is step free access to a row/rows of seating.
    • The row(s) with step free access is/are row(s) the top row.
    • There is stepped access to the majority of seating.
    • There is/are 10 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are not between the 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).
    • The lighting level at the steps before and after performances is low to moderate.
    • The lighting level at the steps during performances is low to moderate.
    • The steps are not clearly illuminated during performances.
  • Designated Seating Area(s) View
    • There is designated seating available in this area.
    • The designated seating area(s) is/are located on the top row of seating.
    • The designated seating area(s) is/are not clearly marked/signed.
    • There is step-free access to the designated seating area(s).
    • There is/are 2 designated space(s) for wheelchair users.
    • Wheelchairs may be left with the patron.
    • The visibility of the stage from this seating area is good.
    • Companions/carers sit next to the patron.
    • There is sufficient space for an assistance dog to rest next to you.

Toilet with Adaptations (Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the first floor, at the rear of the building.
    • This accessible toilet is approximately 21m (22yd 2ft) from the first floor entrance.
    • There is step-free access into the accessible toilet.
    • This is a gender neutral toilet.
    • A key is not required for the accessible toilet.
    • There is Braille, tactile, pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens inwards.
    • The door is heavy.
    • The door is locked by a locking handle.
    • The width of the accessible toilet opening is 84cm (2ft 9in).
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 229cm x 210cm (7ft 6in x 6ft 11in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 99cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 157cm (5ft 2in).
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the left.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is high.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 76cm.
    • The shelf is not located where it is reachable.
    • The toilet has a covered cistern.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 42cm (1ft 5in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 107cm (3ft 6in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) cannot be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 75cm (2ft 6in).
    • There are no vertical wall-mounted grab rails at the wash basin.
    • The wash basin tap type is twist turn mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 94cm.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 91cm (2ft 12in).
    • The contrast between the hand dryer and the wall is high.

Standard Toilet(s)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on the first floor at the rear of the building.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 22m from the first floor entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is Braille, tactile, pictorial and written text signage on or near the toilet door.
    • It was not possible to access the female toilet.
    • An ambulant toilet cubicle is available.
    • There is a/are horizontal wall mounted rail(s) on the right as you face the toilet.
    • There is a/are vertical wall mounted rail(s) on the right as you face the toilet.
    • The height of the wash basin(s) is 94cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.
  • Toilet Facilities 2 View
    • The female and male toilets are located on the ground floor, to the right as you enter via the rear entrance.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 6m from the the rear entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is Braille, tactile, pictorial and written text signage on or near the toilet door.
    • It was not possible to access the female toilet.
    • An ambulant toilet cubicle is available.
    • There is a/are horizontal wall mounted rail(s) on the left as you face the toilet.
    • There is a/are vertical wall mounted rail(s) on the left as you face the toilet.
    • The height of the wash basin(s) is 94cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.