  • Building View
    • Services / Facilities within the building include; a library, student services, cafes, student union shop, lecture theatres, teaching rooms, simulation labs, research labs, computer rooms, meeting rooms and offices.
    • There is a link bridge between Hunter Wing and Jenner Wing,.
    • Jenner Wing link (new tab) - click here.
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located on all floors, ground to sixth.
    • Female standard toilet facilities are located on all floors, ground to sixth.
    • Male standard toilet facilities are located on all floors, ground to sixth.
    • Shared standard toilet facilities are located on the ground floor.
    • Baby changing facilities are located on the ground floor.
    • Standard shower facilities are located on the sixth floor, and within the male and female toilets on the fifth floor.

Rooms and Spaces Links

Getting Here

  • By Road View
    • The University is located within the St George's Hospital Site in Tooting, just off the A24, which joins the A3 and South Circular at Clapham with junction 9 of the M25. At Tooting Broadway, turn onto Garrett Land (A217) towards Wandsworth, then turn left onto Fountain Lane.
    • The university does not have public car parking spaces. There is a limited amount of pay-and-display parking in the area.
  • By Bus View
    • There is a bus stop within 150 metres of the venue.
    • There are several bus stops located directly outside the hospital site, and more on Tooting Broadway. Please see the University Website How To Get Here page for more details on the bus routes to the hospital.
  • By Train View
    • The nearest Railway Station is Tooting.
    • Tooting station is just under a mile from the site, but can be accessed by taking bus 264 or 280 from the station to the Crammer Terrace stop, approximately 300 metres from the site. Earlsfield Station, served by South West Trains, is approximately 1.5 miles to the north of the site. From there take bus 270 to Wimbledon Road (Stop SJ), and then take bus G1 to the Hospital site.
  • By Underground View
    • The nearest underground station is Tooting Broadway station.
    • Tooting Broadway station, on the Northern Line, is approximately half a mile from the University main entrance. Bus G1 can be caught from just outside the station to the University main entrance.
  • Useful Links View

Useful Information

Building Parking

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by staff permit holders and student permit holders.
    • The car park is located on the left hand side of the Hunter Wing building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 2 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) is/are clearly marked.
    • The dimensions of the designated parking bay(s) are 218cm x 420cm.
    • The Blue Badge parking bays have a marked zone to both sides and rear.
    • The marked zone is 120cm wide.
    • The dimensions of the designated bays do not vary in size.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 24m (26yd 9in) from the Hunter Wing main entrance.
    • The route from the car park to the building is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are uneven surfaces.
    • The car park surface is tarmac.
  • Site/Campus Car Parks View
    • There is not a site/campus car park within approximately 200m.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • On Street Parking View
    • Clearly signed and/or standard marked parking bays are not available.
  • Drop Off Point View
    • There is a designated drop off point.
    • There is not a dropped kerb from the drop off point.
    • The drop off point is located to the left of the main entrance.

Outside Access (Hunter Wing Main Entrance)

  • Entrance View
    • This information is for the entrance located on Coverton Road.
    • This entrance gives access to the Hunter Wing ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'School of Health and Medical Sciences'.
    • There is ramped/sloped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is an intercom.
    • The height of the intercom is 116cm (3ft 10in).
    • The main door(s) open(s) by sliding.
    • The door(s) is/are double width.
    • The width of the door opening is 256cm.
    • There is a second set of doors.
    • The door(s) open(s) by sliding.
    • The door(s) is/are double width.
    • The width of the door opening is 260cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There are bollards at this entrance.
    • The minimum width between the bollards is 130cm.
    • The bollards do not contrast visually with the paving.
    • There are bollards at the bottom of the slope on the approach to the right of the entrance.
  • Ramp/Slope View
    • The ramp/slope is located before the entrance on both sides.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the right going up the ramp.

Entrance (From Grosvenor Wing)

  • Entrance View
    • This information is for the entrance located on the ground floor of Grosvenor Wing.
    • This entrance gives access to Hunter Wing.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'City St George's, University of London - Hunter Wing - Jenner Wing'.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 138cm.

Reception (Main Reception)

  • Reception View
    • The reception point is located to the left of the Hunter Wing main entrance.
    • The reception point is approximately 8m (8yd 2ft) from the Hunter Wing main entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are no windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is 110cm.
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 76cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is not a clear knee recess beneath the counter.
    • The counter is staffed.
    • Clipboards can be provided to anyone who is unable to use the desk.
    • There is a hearing assistance system at the reception point.
    • The type of system is a portable loop.
    • The hearing assistance system is not signed.
    • Staff are not trained to use the hearing system.
    • The hearing assistance system was tested by an AccessAble surveyor.
    • The hearing assistance system was tested on 17/03/2025.
    • The hearing loop was working at the time of testing.
    • There is no wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is vinyl.
  • Reception Waiting Area View
    • There is not a waiting area close to the reception point.

Reception (Security Desk)

  • Reception View
    • The reception point is located to the right of main reception.
    • The reception point is approximately 15m (16yd 1ft) from the Hunter Wing main entrance.
    • Clear signage for the reception area/desk is not visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is 104cm.
    • There is not sufficient space to write or sign documents on the counter.
    • There is not a lowered section of the counter.
    • There is not a clear knee recess beneath the counter.
    • The counter is not staffed.
    • There is a bell to attract attention.
    • Clipboards can be provided to anyone who is unable to use the desk.
    • There is not a hearing assistance system at the reception point.
    • There is no wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is vinyl.
  • Reception Waiting Area View
    • There is not a waiting area close to the reception point.

Getting Around

  • Access View
    • There is step-free access throughout the building .
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is carpet and vinyl.
    • There is some flooring in corridors/walkways which is shiny and could cause issues with glare or look slippery to some people.
    • There is high visual contrast between the walls and floor in all areas.
    • There is a mixture of seating with and without armrests at regular intervals.
    • The lighting levels are varied.
  • Signage View
    • Wayfinding signage is provided.
    • Floor plans/maps are available.
    • The colour, design and typeface of signs is consistent throughout the building.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Lecture Theatre(s) (The Curve Lecture Theatre)

  • Signage for the lecture theatre(s) is available in upper and lower case lettering that is clearly visible on or near the door.
  • The corridor outside the lecture theatre(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
  • There is step free access into the lecture theatre(s) from the corridor.
  • The door opening width(s) is/are 75cm+ for the lecture theatre(s).
  • The door(s) for the lecture theatre(s) is/are push pad activated.
  • There are designated spaces for wheelchair users within the lecture theatre(s).
  • The designated spaces for wheelchairs users are located at the front.
  • There is level access to the designated seating from an entrance.
  • There is space for an assistance dog.
  • There is step free access to the speaker's area at the front of the lecture theatre(s).
  • The height of the speaker's desk/table is 91cm.
  • The speaker's desk/table is not height adjustable.
  • There is staggered seating within the lecture theatre(s).
  • The steps to the staggered seating do have handrails.
  • The steps have handrails which are wall mounted on either side of the room.
  • There is not a hearing assistance system for the lecture theatre(s).
  • There is a visual fire alarm beacon in the lecture theatre(s).
  • There is fixed furniture within the lecture theatre(s).
  • The clear floor space beneath tables in the room(s) is 70cm.
  • A height adjustable table/bench is not available.
  • There are no chairs with armrests on both sides within the lecture theatre(s).
  • The room does have an unobstructed minimum turning space of 150cm x 150cm.
  • Floor coverings in the lecture theatre(s) are even with no trip hazards.
  • The Curve Lecture Theatre is located on the ground floor of the Hunter Wing.

Lift (Main)

  • The lift is located at the end of the main corridor, on the left.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 50m (54yd 2ft) from the Hunter Wing main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are ground, first, second, third, fourth, fifth and sixth.
  • Clear signs indicating the facilities on each floor are provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is high.
  • The visual contrast between the external lift control plate and the wall is high.
  • The clear door width is 110cm (3ft 7in).
  • The dimensions of the lift are 190cm x 165cm (6ft 3in x 5ft 5in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are not within 90cm - 120cm from the floor.
  • The sixth floor button is 126cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.
  • There is a/are similar lift(s) available.
  • There are three identical lifts in this area.

Lift (Additional Lifts)

  • The lift is located at the front right hand corner of the building.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 14m (15yd 11in) from the Hunter Wing main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are ground, first, second, third, fourth, fifth and sixth.
  • There are manual, heavy, single doors to access the lift lobby on all floors.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is high.
  • The visual contrast between the external lift control plate and the wall is high.
  • The clear door width is 80cm (2ft 7in).
  • The dimensions of the lift are 103cm x 132cm (3ft 5in x 4ft 4in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are good.
  • Comments View
    • There are similar lifts located at each corner of the building.

Other Floors

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located at the front right hand corner of the building.
    • The stairs are approximately 14m from the Hunter Wing main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by the stairs are ground, first, second, third, fourth, fifth and sixth.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The depth of the steps is 26cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are moderate to good.
  • Comments View
    • There are similar stairs located at each corner of the building alongside a lift.

Reception (Student Helpdesk - Sixth Floor)

  • Reception View
    • The reception point is located on the sixth floor, to the left of the main lifts.
    • The reception point is approximately 8m (8yd 2ft) from the main lifts.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are no windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is 117cm.
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 74cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is not a clear knee recess beneath the counter.
    • The counter is staffed.
    • Clipboards can be provided to anyone who is unable to use the desk.
    • There is not a hearing assistance system at the reception point.
    • There is no wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is vinyl.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • There are sofas only in the waiting area.
    • There is sufficient space for a wheelchair user to use the waiting area.

Standard Shower (Sixth Floor)

  • Shower facilities are available.
  • The shower(s) surveyed is/are located along the left hand main corridor on the sixth floor, next to the toilet with adaptations.
  • There is not level access to the shower facilities.
  • There is a step of 20cm to access the shower cubicle.

Toilet with Adaptations (Ground Floor - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located on the left of the main corridor on the ground floor, next to The Curve Lecture Theatre.
    • This accessible toilet is approximately 28m (30yd 1ft) from the Hunter Wing main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is required for the accessible toilet.
    • The key is a radar key.
    • The key can be obtained from main reception.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a locking handle.
    • The width of the accessible toilet opening is 96cm (3ft 2in).
    • The visual contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is low.
  • Toilet Features View
    • The dimensions of the accessible toilet are 150cm x 218cm (4ft 11in x 7ft 2in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 88cm (2ft 11in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush, however it is not on the transfer side (on top of the cistern).
    • There is not a spatula type lever flush.
    • There is a sensor flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is high.
    • The visual contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is low.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is a/are coat hook(s).
    • There are coat hooks in the toilet at 108cm and 142cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat visual contrast is high.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 94cm (3ft 1in).
    • The visual contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 72cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 95cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 100cm (3ft 3in).
    • The visual contrast between the hand dryer and the wall is high.
  • Baby Changing Facilities View
    • Baby changing facilities are located within the accessible toilet.
    • There is a flip down baby change table available.
    • The height of the baby change table is 84cm.

Toilet with Adaptations (First Floor - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the right of the main lifts on the first floor, opposite the library entrance.
    • This accessible toilet is approximately 8m (8yd 2ft) from the main lifts.
    • There is step-free access into the accessible toilet.
    • This is an all gender toilet.
    • A key is required for the accessible toilet.
    • The key is a radar key.
    • The key can be obtained from the Library Helpdesk.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a locking handle.
    • The width of the accessible toilet opening is 86cm (2ft 10in).
    • The visual contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 150cm x 312cm (4ft 11in x 10ft 3in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 76cm (2ft 6in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is high.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 47cm (1ft 7in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 91cm (2ft 12in).
    • The visual contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 73cm (2ft 5in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 102cm.
    • There is a towel dispenser.
    • The towel dispenser can be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 108cm (3ft 7in).
    • The visual contrast between the towel dispenser and the wall is medium.
    • There is not a hand dryer.

Toilet with Adaptations (Second Floor - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located along the left hand main corridor on the second floor.
    • This accessible toilet is approximately 12m (13yd 4in) from the main lifts.
    • There is step-free access into the accessible toilet.
    • This is an all gender toilet.
    • A key is required for the accessible toilet.
    • The key is a radar key.
    • The key can be obtained from main reception or student union.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens inwards.
    • The door is heavy.
    • The door is locked by a locking handle.
    • The width of the accessible toilet opening is 88cm (2ft 11in).
    • The visual contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 162cm x 240cm (5ft 4in x 7ft 10in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 103cm (3ft 5in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush, however it is not on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is low.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is not a mirror.
    • There is not a shelf within the accessible toilet.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 47cm (1ft 7in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 92cm (3ft).
    • The visual contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 70cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 86cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 90cm (2ft 11in).
    • The visual contrast between the towel dispenser and the wall is low.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 104cm (3ft 5in).
    • The visual contrast between the hand dryer and the wall is low.

Toilet with Adaptations (Fourth Floor - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located along the left hand main corridor on the fourth floor.
    • This accessible toilet is approximately 6m (6yd 1ft) from the main lifts.
    • There is step-free access into the accessible toilet.
    • This is an all gender toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 82cm (2ft 8in).
    • The visual contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 162cm x 183cm (5ft 4in x 6ft).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 134cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 78cm (2ft 7in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush, however it is not on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail, however it is not on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is not a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is low.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 185cm from the floor.
  • Additional Fixtures View
    • There is not a mirror.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 99cm.
    • The shelf is not located where it is reachable.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 65cm (2ft 2in).
    • The visual contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 78cm (2ft 7in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 71cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 106cm (3ft 6in).
    • The visual contrast between the towel dispenser and the wall is medium.
    • There is not a hand dryer.
  • Comments View
    • There is an additional adapted toilet located along the right hand main corridor on this floor.

Toilet with Adaptations (Fifth Floor- Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located along the left hand main corridor on the fifth floor.
    • This accessible toilet is approximately 12m (13yd 4in) from the main lifts.
    • There is step-free access into the accessible toilet.
    • This is an all gender toilet.
    • A key is required for the accessible toilet.
    • The key is a radar key.
    • The key can be obtained from main reception.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a locking handle.
    • The width of the accessible toilet opening is 84cm (2ft 9in).
    • The visual contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 161cm x 185cm (5ft 3in x 6ft 1in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 136cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 77cm (2ft 6in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush, however it is not on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail, however it is not on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is not a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is medium.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 184cm from the floor.
  • Additional Fixtures View
    • There is not a mirror.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 99cm.
    • The shelf is not located where it is reachable.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 47cm (1ft 7in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 63cm (2ft 1in).
    • The visual contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 76cm (2ft 6in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 70cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 100cm (3ft 3in).
    • The visual contrast between the towel dispenser and the wall is medium.
    • There is not a hand dryer.

Toilet with Adaptations (Sixth Floor - Left Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located along the left hand main corridor on the sixth floor.
    • This accessible toilet is approximately 14m (15yd 11in) from the main lifts.
    • There is step-free access into the accessible toilet.
    • This is an all gender toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is low.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 86cm (2ft 10in).
    • The visual contrast between the internal door and wall is medium.
    • The door has a horizontal grab rail.
    • The visual contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 162cm x 183cm (5ft 4in x 6ft).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 135cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 82cm (2ft 8in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush, however it is not on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail, however it is not on the transfer side.
    • The visual contrast between the dropdown rail(s) and wall is medium.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the right.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is not a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The visual contrast between the wall-mounted grab rail(s) and wall is medium.
    • The visual contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 128cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 100cm.
    • The shelf is not located where it is reachable.
    • The toilet has a cistern.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 61cm (2ft).
    • The visual contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 76cm (2ft 6in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The visual contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser can be reached from seated on the toilet.
    • The height of the soap dispenser is 68cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 92cm (3ft).
    • The visual contrast between the towel dispenser and the wall is medium.
    • There is not a hand dryer.

Standard Toilet(s) (Ground Floor)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on the left of the main corridor, next to The Curve Lecture Theatre on the ground floor.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 28m from the Hunter Wing main entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • It was not possible to access the male toilet.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 82cm.
    • The wash basin(s) tap type is sensor.
    • Lighting levels are good.
  • Toilet Facilities 2 View
    • The shared toilet is located on the left of the main corridor, next to The Curve Lecture Theatre on the ground floor.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 28m from the Hunter Wing main entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 82cm.
    • The wash basin(s) tap type is lever mixer.
    • Lighting levels are good.

Standard Toilet(s) (First to Sixth Floors)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on the second floor.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 6m from the main lifts.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • It was not possible to access the male toilet.
    • An ambulant toilet cubicle is available.
    • There is a/are horizontal wall mounted rail(s) on the left as you face the toilet.
    • There is a/are vertical wall mounted rail(s) on the right as you face the toilet.
    • There is a/are dropdown rail(s) on the right as you face the ambulant toilet(s).
    • The height of the wash basin(s) is 90cm.
    • The height of the lowered wash basin is 76cm.
    • The wash basin(s) tap type is lever mixer.
    • Lighting levels are good.
  • Toilet Facilities 2 View
    • The female and male toilets are located on the fifth floor.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 6m from the main lifts.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • It was not possible to access the male toilet.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 90cm.
    • The wash basin(s) tap type is sensor.
    • Lighting levels are good.
    • There is a shower available within the toilets on the fifth floor. There is a step of 29cm to enter the shower cubicle.
  • Comments View
    • There are male and female toilets located in the same place on each floor. Only the second floor toilet has an ambulant cubicle.