Location of Room(s)

Teaching/Seminar Room(s)

  • Directional and locational signage for the room(s) is available in upper and lower case lettering that is clearly visible.
  • The corridor outside the room(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
  • There is step free access into the room(s).
  • The door opening width(s) is/are 75cm+ for the room(s).
  • The door(s) for the room(s) is/are not push pad activated.
  • There is not a hearing assistance system for the room(s).
  • There is a visual fire alarm beacon in the room(s).
  • There is not fixed furniture within the room(s).
  • There is sufficient space for a wheelchair user to manoeuvre within the room(s).
  • A height adjustable table/bench is available.
  • There is a/are chair(s) with armrests on both sides within the room(s).
  • Floor coverings in the room(s) are even with no trip hazards.
  • There is a fake reception in the room with a height of 108cm and a lower section of 78cm. 1.21F and 1.21P are located within the room as is an accessible toilet.

Accessible Toilet

  • Accessible toilet facilities are available.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the 1.21B room entrance.
    • This accessible toilet is located to your right on entrance to the room.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 86cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 155cm x 275cm (5ft 1in x 9ft).
    • There is a clear 150cm x 150cm manoeuvring space in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are available in the cubicle.
    • There is a/are waste paper pedal bin disposal units.
    • There is not a/are not coat hook(s).
  • Position of Fixtures View
    • Wall-mounted grab rails are available for the toilet.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is not a mirror.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 104cm (3ft 5in).
    • There is not a toilet roll holder.
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • There is a high colour contrast between the internal door and wall.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is good.
    • There is a good colour contrast between the dropdown rail(s) and wall.
    • The toilet seat colour contrast is good.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.