Skip to main content
The new name for DisabledGo

College of St Hild & St Bede - Bede Main Residential

College of St Hild & St Bede, Durham, DH1 1SZ

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Accommodation Summary

  • Parking and Transport View
    • The accommodation has its own parking facilities.
    • No secure parking is available.
    • There is not a designated drop off point.
    • There is not a university bus service stop within approximately 200 metres of the residence.
  • Accessible Accommodation Information View
    • The accommodation has 0 rooms in total.
    • There is not an/are not accessible room(s) within the accommodation.
  • Standard Accommodation Information View
    • There is standard accommodation on the ground floor.
    • Ground floor accommodation does not have level access.
    • There are standard rooms on other floors.
    • The other floors cannot be accessed by lift.
    • Standard accommodation has shared bathrooms with stepped shower cubicles.
    • There is not an/are not adjoining room(s) available for the standard room(s).
  • Amenities and Communal Facilities View
    • There is not a convenience store within approximately 200 metres of the residence.
    • Communal facilities within this residence include a staffed reception, a launderette, a common room, a recreation room and a study area.
    • The communal facilities for the accommodation surveyed include; a kitchen.
  • Additional Accessibility Aids View
    • There is not a deaf alert system available on request.
    • Bed raisers are not available on request.
    • Portable hoists are not available on request.

Getting Here

Useful Information

Building Parking

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by permit holders.
    • There are no parking charges that apply on the day.
    • The car park is located in front of the building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are not available.
    • The dropped kerb between the car park and the building does not have tactile paving.
    • The car park surface is tarmac.
  • Drop Off Point View
    • There is not a designated drop off point.
    • To enter the car park there is a steep slope which leads down into the parking bays.

Outside Access (Laundry)

  • Entrance View
    • This information is for the entrance located to the right of the main entrance stairs as you face them.
    • This entrance gives access to the laundry room.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'LAUNDRY'.
    • There is stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are light.
    • The width of the door opening is 71cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Step(s) View
    • The step(s) is/are located in front of and beyond the door.
    • There is/are 2 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).
    • The lighting levels at the step(s) are moderate to good.
  • Comments View
    • The laundry room contains dryers at high level where the washing machines are at the bottom.

Outside Access (Bede Main Residential)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the ground floor.
    • The entrance area/door is not clearly signed.
    • There is stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 79cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 75cm.
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 14 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the left going up the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.
  • Comments View
    • The first 7 steps have hand rails on both sides.

Inside Access

  • Access and Circulation View
    • There is not step-free access throughout the building.
    • The type of flooring is carpet and vinyl.
    • There is high colour contrast between the walls and floor.
    • The lighting levels are good.
  • Signage View
    • Wayfinding signage is not provided.
    • The colour, design and typeface of signs is not consistent throughout.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.

Other Floors

  • Stairs View
    • The stairs are located within the main corridor past the internal steps.
    • The stairs are approximately 15m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • The floors which are accessible by stairs are G, 1, 2 and 3.
    • There are 14 steps between floors.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 19cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.
  • Other Information View
    • There are a set of stairs which are located in the rear of the building, they provide access to the fire exit and other floors (photograph 5, 6, 7, 8 and 9).

Step(s)

  • Stepped Level Change 1 View
    • There is a/are step(s) located in the main corridor leading to the stairs.
    • The step(s) is/are used to access the stairs and room 100-104.
    • There is/are 6 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on the left going up.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
    • There are additional level changes located around the building (photograph 3, 4, 5 and 6).

Kitchen/Dining Area

  • The kitchen/dining area is accessed by a single door with an opening width of over 75cm.
  • Lowered work surfaces are not available.
  • The height of the lowest work surface is 92cm.
  • The kitchen does not have an unobstructed floor space of at least 150cm × 150cm.
  • There is not a knee recess under a work surface.
  • Knee recesses are not at least 80cm wide.
  • There are low level cupboards.