Access Guide
Summary
-
Building
View
- Services / Facilities within the building include; the Institute of Hazard, Risk and Resilience offices, visiting lecturers offices, meeting rooms, postgraduate research rooms, Gordon Manley social room.
- West Building - Geography link (new tab) - click here.
-
Location of Toilet/Changing Facilities
View
- Accessible toilet facilities are located on the lower ground floor (West Building link corridor), ground floor.
- Shared standard toilet facilities are located on the lower ground floor (West Building link corridor), first floor (ambulant).
- Standard shower facilities are located in the accessible toilet on the lower ground floor (West Building link corridor).
Getting Here (Lower Mountjoy Site)
-
By Road
View
- The building is located in the Lower Mountjoy site toward the South Road entrance side (west). The A177 South Road links the A167 Darlington Road, at the Cock o' the North Roundabout with the A177 Stockton Road on the south side of the City Centre.
- There are individual Blue Badge bays across the site for permit holders. There is Blue Badge parking at the Lower Mountjoy site - South Road entrance.
There is a campus car park for standard parking on the other side (east) of the site, accessed from Stockton Road. This car park has electric car charging points.
The nearest public on-street pay and display parking is either on Stockton Road to the north-east, or Quarryheads Lane to the north-west. - For more information on getting to Durham University please click here (opens new tab).
-
By Bus
View
- There is a bus stop within 150 metres of the campus.
- The nearest bus stops are on Stockton Road to the north-east of the site, "University - Palatine Centre" stops, served by bus routes 40BD, 56,57, 57A, 58, X12, M20 (westbound) and 853 (eastbound).
Additional bus stops are on Quarryheads Lane to the north-west, "New Inn - Quarryheads Lane" stops, served by bus routes 6, 21 (eastbound), 40BD, 56,57, 57A, 58, ED1, S1, N21 and X12.
. - For more information on bus services to the Lower Mountjoy site please click here (opens new tab).
-
By Train
View
- The nearest Railway Station is Durham.
- Durham Railway Station is located approximately 1.3 miles to the north of the Lower Mountjoy site, on the far side of the city centre and River Wear. Buses run from outside the station to the city centre. This station is a category A station and has step free access to all platforms. Interchange between the platforms is via a subway. Lift access is available to the subway from both platforms.
- For more information on local and national train service to Durham please click here (opens new tab).
- For more information on services and facilities at Durham Railway Station please click here (opens new tab).
Useful Information
- Disability Support is located on the ground floor in the Palatine Centre, and provides information, advice and guidance to prospective and current students who disclose a disability as well as students who think they may have a disability.
The service is part of the Student Support and Wellbeing Directorate. - To see more information on Disability Support please click here (opens new tab).
- To see more information on Student Support and Wellbeing please click here (opens new tab).
- To see more information on Applying To Durham please click here (opens new tab).
- To see more information on College Accommodation and Facilities please click here (opens new tab).
- To see more information on Accommodation and Allocations Office please click here (opens new tab).
Building Parking
- The building does have its own dedicated parking.
-
Building Car Park
View
- The car park can be used by Blue Badge holders.
- There are no parking charges that apply on the day.
- The car park is located to the side of the IHRR building opposite the Rochester Building.
- The car park type is open air/surface.
- The car park does not have a height restriction barrier.
- Designated Blue Badge parking bays are available.
- There is/are 2 designated parking bay(s) within the car park.
- The Blue Badge bay(s) is/are signposted but have no markings.
- Parking spaces for Blue Badge holders do need to be booked in advance.
- The nearest designated bay is 5m (5yd 1ft) from the main entrance.
- The route from the car park to the building is accessible to a wheelchair user.
- The car park surface is block paving.
-
Site/Campus Car Parks
View
- There is a site/campus car park for staff and students within approximately 200m.
- The name of the car park is Lower Mountjoy - South Road Entrance.
- The car park is located at the South Road entrance of the Lower Mountjoy site.
-
Public Car Parks
View
- There is not a car park for public use within 200m (approx).
-
On Street Parking
View
- The on street Blue Badge parking bay(s) is/are located on Stockton Road.
- Clearly signed and/or standard marked parking bays are available.
- The dimensions of the standard marked parking bays are 200cm x 4000cm (6ft 7in x 131ft 3in).
-
Drop Off Point
View
- There is not a designated drop off point.
Site/Campus Car Park (Lower Mountjoy - South Road Entrance)
-
Car Park
View
- The car park is located in Lower Mountjoy off South Road.
- The nearest building(s) to this car park is/are Ogden Centre West, Physics Rochester.
- The car park type is open air/surface.
- The car park does not have a height restriction barrier.
- The car park surface is block paving.
- Designated Blue Badge parking bays are available.
- The Blue Badge bay(s) is/are clearly marked.
- There is/are 4 designated Blue Badge parking bay(s) within this car park.
-
Drop Off Point
View
- There is not a designated drop off point in this car park.
Approach
-
Approach
View
- The surface of the approach is stone/concrete tiles.
- There is a/are fixed bollard(s) on the approach .
- The minimum width between the bollards/wall is 189cm.
- The bollard(s) does/do not have a high colour contrast to prevent them being hazardous to visually impaired people.
- The bollards are stainless steel with an identification band.
- There is step-free access on the approach.
- There is a slope with a very easy incline.
Outside Access
-
Entrance
View
- This information is for the entrance located at the end of the building near the West Building entrance.
- This entrance gives access to the ground floor entrance foyer.
- The entrance area/door is clearly signed.
- This entrance is signed with 'Geography - Institute of Hazard, Risk and Resilience'.
- There is step-free access at this entrance.
- There is not a canopy or recess which provides weather protection at this entrance.
- There is a dark mat or floor marking at this entrance that might be perceived as a hole.
- The entrance door(s) does/do contrast visually with its immediate surroundings.
- There is not a bell/buzzer.
- There is not an intercom.
- The main door(s) open(s) automatically.
- The door(s) is/are double width.
- The width of the door opening is 163cm.
- There is a small lip on the threshold of the entrance, with a height of 2cm or below.
- There is a second set of doors.
- The door(s) open(s) automatically.
- The door(s) is/are double width.
- The width of the door opening is 151cm.
Getting Around
-
Access
View
- There is step-free access throughout the building via lift(s).
- The building consists of a ground and first floor, with a lower ground floor link staircase and lift link to the West Building ground floor.
Other Floors
-
Stairs
View
- Stairs can be used to access other floors.
- The stairs are located on the left of the main corridor.
- The stairs are approximately 15m from the main entrance.
- Signs indicating the location of the stairs are not available from the entrance.
- There are manual, heavy, single doors to enter and exit the stairwell on both floors. The door at ground floor level is held on a magnetic catch.
- The floors which are accessible by stairs are G and 1.
- There are 15+ steps between floors.
- The height of the step(s) is/are between the recommended 15cm and 18cm.
- The height of the step(s) is/are 17cm.
- The depth of the step(s) is/are not between the recommended 30cm and 45cm.
- The steps are clearly marked.
- There is a/are handrail(s) at the step(s).
- The steps have a handrail on both sides.
- Handrails are at the recommended height (90cm-100cm).
- Handrails do cover the flight of stairs throughout its length.
- Handrails are easy to grip.
- Handrails do extend horizontally beyond the first and last steps.
- There is a landing.
- Clear signs indicating the facilities on each floor are provided on landings.
- The lighting levels at the steps are moderate to good.
Lift
- The lift is located on the lift of the corridor as you enter.
- Signs indicating the location of the lift are not available from the entrance.
- The lift is approximately 10m (10yd 2ft) from the main entrance.
- The lift is a standard lift.
- A member of staff does not need to be notified for use of the lift.
- The floors which are accessible by this lift are LG, G and 1.
- The weight limit for the lift is 630Kg 8 Persons.
- Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
- There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
- Lift doors do contrast visually with lift lobby walls.
- The external controls for the lift are within 90cm - 110cm from the floor.
- The colour contrast between the external lift controls and the control plate is high.
- The clear door width is 80cm.
- The dimensions of the lift are 110cm x 140cm.
- There are separate entry and exit doors in the lift.
- There is a mirror to aid reversing out of the lift.
- There is not a list of floor services available within the lift.
- The lift does have a visual floor indicator.
- The lift does have an audible announcer.
- The internal controls for the lift are within 90cm - 120cm from the floor.
- There is not a hearing loop system.
- The lift does have Braille markings.
- The lift does have tactile markings.
- The lighting levels in the lift are moderate to good.
- This lift gives link access to the West Building at LG level.
Other Floors (West Building Link)
-
Stairs
View
- Stairs can be used to access other floors.
- The stairs are located to the left as you enter the building.
- The stairs are approximately 5m from the main entrance.
- Signs indicating the location of the stairs are not available from the entrance.
- There is a manual, single, heavy door to access the stairwell on the IHRR Ground Floor.
- The floors which are accessible by stairs are G and LG.
- There are 15+ steps between floors.
- The height of the step(s) is/are between the recommended 15cm and 18cm.
- The height of the step(s) is/are 17cm.
- The depth of the step(s) is/are between the recommended 30cm and 45cm.
- The steps are clearly marked.
- There is a/are handrail(s) at the step(s).
- The steps have a handrail on both sides.
- Handrails are at the recommended height (90cm-100cm).
- Handrails do cover the flight of stairs throughout its length.
- Handrails are easy to grip.
- Handrails do extend horizontally beyond the first and last steps.
- There is a landing.
- Clear signs indicating the facilities on each floor are not provided on landings.
- The lighting levels at the steps are low to moderate.
Accessible Toilet(s) (Ground Floor - Left Transfer)
- There is an/are accessible toilet(s) available.
-
Location and Access
View
- This accessible toilet is located to the left as you enter via the main entrance, in the corridor to the postgraduates room.
- This accessible toilet is approximately 5m (5yd 1ft) from the main entrance.
- There is step-free access into the accessible toilet.
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial and ‘Not All Disabilities Are Visible’ signage on or near the toilet door.
- The contrast between the external door and wall is high.
- The door opens inwards.
- The door is heavy.
- The door is locked by a lever twist.
- The width of the accessible toilet opening is 103cm.
- The contrast between the internal door and wall is high.
- The door has a horizontal grab rail.
- The contrast between the horizontal grab rail and internal door is high.
-
Toilet Features
View
- The dimensions of the accessible toilet are 162cm x 200cm (5ft 4in x 6ft 7in).
- The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
- The lighting levels are moderate to good.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the left.
- The lateral transfer space is 80cm (2ft 7in).
- The transfer space is obstructed by a female sanitary bin.
- There is a flush on the transfer side.
- There is not a spatula type lever flush.
- There is a lever flush.
- There is a dropdown rail on the transfer side.
- The contrast between the dropdown rail(s) and wall is high.
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
- There is a vertical wall-mounted grab rail on the transfer side.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- The contrast between the wall-mounted grab rail(s) to the left of the toilet and wall is high.
- The contrast between the wall-mounted grab rail(s) to the right of the toilet and wall is low.
- The contrast between the walls and floor is high.
- There is an emergency alarm.
- The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
- There is not a red flashing fire alarm beacon within the toilet.
- Disposal facilities are available in the toilet.
- There is a/are female sanitary and pedal bin disposal units.
- There is not a/are not coat hook(s).
-
Additional Fixtures
View
- There is a mirror.
- The mirror is not placed at a lower level or at an angle for ease of use.
- There is not a shelf within the accessible toilet.
- The toilet has a wall which acts as a backrest.
- There is a lid attached to the toilet seat.
- The height of the toilet seat above floor level is 52cm (1ft 8in).
- The toilet seat colour contrast is low.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- The height of the toilet roll holder is 94cm (3ft 1in).
- The contrast between the toilet roll holder and the wall is medium.
- There is a wash basin.
- The wash basin and tap(s) can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The height of the wash basin is 72cm (2ft 4in).
- There are vertical wall-mounted grab rails on both sides of the wash basin.
- The contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
- The wash basin tap type is lever mixer.
- There is a wall fixed soap dispenser.
- The soap dispenser can be reached from seated on the toilet.
- The height of the soap dispenser is 96cm.
- There is a towel dispenser.
- The towel dispenser cannot be reached from seated on the toilet.
- The towel dispenser is not placed higher than 100cm (3ft 3in).
- The height of the towel dispenser is 100cm (3ft 3in).
- The contrast between the towel dispenser and the wall is medium.
- There is a hand dryer.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- The height of the hand dryer is 75cm (2ft 6in).
- The contrast between the hand dryer and the wall is medium.
-
Comments
View
- There are additional accessible toilet and shower facilities on the lower ground floor in the West Building 10m from the lift.
Accessible Toilet(s) (First Floor - Ambulant Only)
- There is an/are accessible toilet(s) available.
-
Location and Access
View
- This accessible toilet is located on the first floor in the stairwell off the first floor corridor, to the left as you exit the lift.
- This accessible toilet is approximately 10m (10yd 2ft) from the lift.
- There is step-free access into the accessible toilet.
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial and ‘Not All Disabilities Are Visible’ signage on or near the toilet door.
- The contrast between the external door and wall is high.
- The door opens inwards.
- The door is heavy.
- The door is locked by a lever twist.
- The width of the accessible toilet opening is 80cm.
- The contrast between the internal door and wall is high.
- The door does not have a horizontal grab rail.
-
Toilet Features
View
- The dimensions of the accessible toilet are 125cm x 215cm (4ft 1in x 7ft 1in).
- The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
- The lighting levels are moderate to good.
- There is not a lateral transfer space.
- There is a flush, however it is not on the transfer side.
- There is not a spatula type lever flush.
- There is a lever flush.
- There is a dropdown rail, however it is not on the transfer side.
- The contrast between the dropdown rail(s) and wall is high.
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on the left.
- There is not a vertical wall-mounted grab rail on the transfer side.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- The contrast between the wall-mounted grab rail(s) and wall is high.
- The contrast between the walls and floor is high.
- There is an emergency alarm.
- The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
- There is not a red flashing fire alarm beacon within the toilet.
- Disposal facilities are available in the toilet.
- There is a/are female sanitary and pedal bin disposal units.
- There is not a/are not coat hook(s).
-
Additional Fixtures
View
- There is a mirror.
- The mirror is not placed at a lower level or at an angle for ease of use.
- There is a shelf within the accessible toilet.
- The shelf has the minimum dimensions of 12.5cm x 40cm.
- The shelf is at a height of 112cm.
- The shelf is located where it is reachable.
- The toilet has a wall which acts as a backrest.
- There is a lid attached to the toilet seat.
- The height of the toilet seat above floor level is 48cm (1ft 7in).
- The toilet seat colour contrast is low.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- The height of the toilet roll holder is 92cm (3ft).
- The contrast between the toilet roll holder and the wall is medium.
- There is a wash basin.
- The wash basin and tap(s) can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The height of the wash basin is 68cm (2ft 3in).
- There are no vertical wall-mounted grab rails at the wash basin.
- The wash basin tap type is lever mixer.
- There is a wall fixed soap dispenser.
- The soap dispenser can be reached from seated on the toilet.
- The height of the soap dispenser is 84cm.
- There is a towel dispenser.
- The towel dispenser cannot be reached from seated on the toilet.
- The towel dispenser is placed higher than 100cm (3ft 3in).
- The height of the towel dispenser is 111cm (3ft 8in).
- The contrast between the towel dispenser and the wall is medium.
- There is a hand dryer.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- The height of the hand dryer is 84cm (2ft 9in).
- The contrast between the hand dryer and the wall is medium.
Accessible Toilet(s) (Link Corridor - Left Transfer)
- There is an/are accessible toilet(s) available.
-
Location and Access
View
- This accessible toilet is located on the lower ground floor in the link corridor from the West Building ground floor to the IHRR lift and link stairs.
- This accessible toilet is approximately 10m (10yd 2ft) from the lift.
- There is step-free access into the accessible toilet.
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial and ‘Not All Disabilities Are Visible’ signage on or near the toilet door.
- The contrast between the external door and wall is high.
- The door opens outwards.
- The door is heavy.
- The door is locked by a lever twist.
- The width of the accessible toilet opening is 95cm.
- The contrast between the internal door and wall is high.
- The door has a horizontal grab rail.
- The contrast between the horizontal grab rail and internal door is high.
-
Toilet Features
View
- The dimensions of the accessible toilet are 315cm x 234cm.
- The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
- The lighting levels are moderate to good.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the left.
- The lateral transfer space is 244cm.
- The transfer space is obstructed by a female sanitary bin.
- There is a flush on the transfer side.
- There is not a spatula type lever flush.
- There is a lever flush.
- There is no dropdown rail.
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on the right.
- There is not a vertical wall-mounted grab rail on the transfer side.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- The contrast between the wall-mounted grab rail(s) and wall is poor.
- The contrast between the walls and floor is high.
- There is an emergency alarm.
- The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
- There is not a red flashing fire alarm beacon within the toilet.
- Disposal facilities are available in the toilet.
- There is a/are female sanitary and pedal bin disposal units.
- There is a/are coat hook(s).
- The height of the coat hook is 179cm from the floor.
-
Additional Fixtures
View
- There is a mirror.
- The mirror is not placed at a lower level or at an angle for ease of use.
- There is not a shelf within the accessible toilet.
- The toilet has a backrest.
- The height of the toilet seat above floor level is 48cm (1ft 7in).
- The toilet seat colour contrast is low.
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- The height of the toilet roll holder is 91cm (2ft 12in).
- The contrast between the toilet roll holder and the wall is medium.
- There is a wash basin.
- The wash basin and tap(s) can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The height of the wash basin is 74cm (2ft 5in).
- There are vertical wall-mounted grab rails on both sides of the wash basin.
- The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
- The wash basin tap type is lever mixer.
- There is a wall fixed soap dispenser.
- The soap dispenser can be reached from seated on the toilet.
- The height of the soap dispenser is 92cm.
- There is a towel dispenser.
- The towel dispenser cannot be reached from seated on the toilet.
- The towel dispenser is not placed higher than 100cm (3ft 3in).
- The height of the towel dispenser is 97cm (3ft 2in).
- The contrast between the towel dispenser and the wall is medium.
- There is a hand dryer.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- The height of the hand dryer is 87cm (2ft 10in).
- The contrast between the hand dryer and the wall is medium.
-
Accessible Shower
View
- The shower does have an unobstructed minimum 150cm x 150cm turning space.
- There is a shower unit with a detachable shower head.
- The shower head is height adjustable.
- The adjustable shower head cannot be placed between 105cm and 185cm when mounted.
- A shower chair is available.
- The seat/chair is not height adjustable.
- The height of the flip-down/tip-up or fixed seat is 62cm.
- There are not horizontal and/or dropdown rails available on both sides of the shower seat.
- There is not a vertical grab rail for the shower.
-
Comments
View
- The alarm for the room is located near the shower area.
Standard Toilet(s) (Link Corridor)
- Standard toilet facilities are available.
-
Toilet Facilities
View
- The shared toilet is located on the lower ground floor in the link corridor from the West Building ground floor to the IHRR lift and link stairs.
- There is step-free access into the toilet(s).
- The standard toilet(s) is/are approximately 7m from the lift on the lower ground floor.
- The colour contrast between the external toilet door(s) and wall(s) is high.
- There is written text signage on or near the toilet door.
- An ambulant toilet cubicle is not available.
- The height of the wash basin(s) is 79cm.
- The wash basin(s) tap type is twist/turn.
- Lighting levels are moderate to good.
- There are two facilities here, each with two cubicles.