Summary

Accommodation Overview

  • About View
    • The accommodation is located on the first and second floors of the Stanley Building.
    • The accommodation comprises of 3 blocks on 2 floors of one building.
    • There are 49 rooms in Stanley.
    • There are no rooms with adaptations in Stanley.
    • Standard accommodation has ensuites with stepped shower cubicles.
  • Parking and Public Transport View
    • The venue does not have its own car park.

Rooms and Spaces Links

Getting Here

Useful Information

Building Parking

  • The building does not have its own dedicated parking.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff, students and visitors within approximately 200m.
    • The name of the car park is Car Park C.
    • The car park is located in the southeast corner of the university campus.
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Parking

  • There are 3 car parks available on Campus (A, B and C) available for use of permit holding students and visitors.
  • Car parks A and C have Blue Badge parking available.
  • There is a drop off point available close to Car Park C.
  • For information about the site/campus parking, please click here to see the Site/Campus Parking Access Guide.
  • To see the Universities Car Parking Policy, please click here.

Outside Access

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to level 0.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'Stanley'.
    • There is step-free access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is a bell/buzzer.
    • The height of the bell/buzzer is 114cm (3ft 9in).
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 100cm.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 138cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 156cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a button to unlock the outer door as you exit.
      The height of the button is 127cm.

Entrance (To Main Entrance - Reception Corridor)

  • Entrance View
    • This information is for the entrance located opposite the Stanley Building toilets.
    • This entrance gives access to the level 0 of Main Building - Reception.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 140cm.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 125cm.

Getting Around

  • Access View
    • There is step-free access throughout the area.
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is vinyl and wood.
    • There is some flooring in corridors/walkways which includes patterns or colours which could be confusing or look like steps or holes to some people.
    • There is some flooring in corridors/walkways which is shiny and could cause issues with glare or look slippery to some people.
    • There is high visual contrast between the walls and floor in all corridors/walkways.
    • There is a mixture of seating with and without armrests at regular intervals.
    • The lighting levels are good.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is consistent throughout the building.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Other Floors (To Accommodation Block A)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located opposite the standard toilets.
    • The stairs are approximately 22m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell from the first floor upwards.
    • The floors which are accessible by the stairs are 0, 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are good.

Other Floors (To Accommodation Blocks B and C)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located along the right-hand corridor after entering the building.
    • The stairs are approximately 21m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, single doors to enter and exit the stairwell from the first floor upwards.
    • The floors which are accessible by the stairs are 0, 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the right going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are good.

Getting Around (Residential Floors)

  • There is stepped access to all residential areas of Stanley. However there is step-free level access once on each floor.
  • Access to blocks A1 and A2 is via the staircase signed as 'Clough and Stanley - Block A'.
  • Access to blocks B1, B2, C1 and C2 is via the staircase signed as 'Stanley, Blocks B, C'.
  • Floor surfaces along all circulation routes are comprised of short pile carpet with some patterning.
  • Each block within Stanley has a combined kitchen and searing area.
  • There is wayfinding signage on each staircase landing.
  • There are manual doors to access accommodation corridors on all floors. These doors are accessed by means of a key card reader.

Kitchen/Dining (Block A1)

  • The kitchen/dining area is located on the first floor of Stanley in Block A1.
  • There is step-free level access into the kitchen/dining area.
  • There is a single manual door with a high visual contrast.
  • The door opens inwards.
  • The door requires effort to open.
  • The width of the opening is 76cm.
  • The walls and floor visual contrast varies between low and high.
  • The work surface is 89cm from the floor.
  • A lowered work surface is not available.
  • Overhead and under counter cupboards are available.
  • The hob is 91cm from the floor.
  • A lowered hob is not available.
  • The oven is at a suitable height for a wheelchair user.
  • The sink is 91cm from the floor.
  • A lowered sink is not available.
  • The sink has a lever mixer tap.
  • Facilities within the kitchen include a fridge, a freezer, a washing machine, a microwave, a kettle and a toaster.
  • The following machines are at a suitable height for a wheelchair user: washing machine.
  • Seating available in the kitchen includes: chairs without armrests, sofas and high stools.
  • Furniture available in the kitchen includes: tables.
  • Some tables are fixed.
  • The surface height of some of the tables is suitable for wheelchair users.
  • The clear height under some of the tables is suitable for wheelchair users.
  • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Level 0 - Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located along the right-hand corridor after entering the building.
    • This accessible toilet is approximately 18m (19yd 2ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a locking handle.
    • The width of the accessible toilet opening is 87cm (2ft 10in).
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 178cm x 249cm (5ft 10in x 8ft 2in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 110cm (3ft 7in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on the left.
    • There is not a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is low.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary, nappy/incontinence items bin and general waste (with no lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is a shelf within the accessible toilet.
    • The shelf has the minimum dimensions of 12.5cm x 40cm.
    • The shelf is at a height of 94cm.
    • The shelf is not located where it is reachable.
    • The toilet does not have a backrest or a cistern.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 45cm (1ft 6in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 100cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 77cm (2ft 6in).
    • There is a vertical wall-mounted grab rail on the right hand side of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is medium.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 119cm.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 120cm (3ft 11in).
    • The visual contrast between the towel dispenser and the wall is medium.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 96cm (3ft 2in).
    • The contrast between the hand dryer and the wall is low.

Standard Toilet(s)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located opposite the internal entrance from Main Building - Reception.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 23m from the external Stanley building entrance.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is Braille, tactile, pictorial and written text signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 86cm.
    • The wash basin(s) tap type is twist/turn.
    • Lighting levels are moderate to good.