Skip to main content
The new name for DisabledGo

N Block

Uxbridge Campus, Park Road, Uxbridge, Middlesex, UB8 1NQ

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Building View
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located on the first floor, in the access corridor.
    • Female standard toilet facilities are located on the first floor, in the access corridor.
    • Male standard toilet facilities are located on the first floor, in the access corridor.

Useful Information

Entrance (The Mall)

  • Entrance View
    • This information is for the entrance located towards the end of / exit from The Mall, near the security barriers.
    • This entrance gives access to the ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'N Block'.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are permanently held open.
    • The width of the door opening is 150cm.

Getting Around

  • Access View
    • There is step-free access throughout the building via lift(s).
  • Circulation View
    • There are no doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is carpet.
    • There is high visual contrast between the walls and floor in all corridors/walkways.
    • There are no seats/chairs at regular intervals.
    • The lighting levels are good.
  • Signage View
    • Wayfinding signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Step(s) (C Block, N Block (East))

  • Stepped Level Change 1 View
    • There is a/are step(s) located in the adjoining C Block and N Block on the first floor.
    • The step(s) is/are used to access the first floors between C Block and N Block (East).
    • There is/are 9 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are moderate to good.
    • The first floor steps are shown in the photographs. There is a refuge point on the upper landing. There is level access via a lift to the refuge point from N Block only. The doorway to C Block is shown in the photographs.
  • Stepped Level Change 2 View
    • There is a/are step(s) located in adjoining C Block (LRC C Wing) and N Block on the second floor.
    • The step(s) is/are used to access the second floors between C Block (LRC C Wing) and N Block (East).
    • There is/are 11 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are low to moderate.
    • The first floor steps are 30m from the C Block lift via a corridor. The second floor steps are 30m from the C Block (LRC C Wing) lift via the LRC The LRC (C Wing) requires a key card for entry. Key card access is allocated by Learning Support. The key card reader is 115cm above the floor.
  • Comments View
    • These steps connect C Block first floor with N Block first floor, and C Block second floor (LRC C Wing) with N Block second floor.
    • There is no access between floors in the same block using these steps.
    • The steps are 20m from the N Block lift.
    • There is a manual heavy single door with a locked leaf to access the steps on both floors and the open door width is 87cm.
    • Access to/from C Block requires a key card.
    • Key card access is allocated by Learning Support.
    • The key card reader is 110cm above the floor.

Lift

  • The lift is located along from the N Block entrance, on the left.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 13m (14yd 8in) from the entrance.
  • The lift is a standard lift.
  • A member of staff needs to be notified for use of the lift.
  • The floors which are accessible by this lift are 0, 1, 2.
  • The weight limit for the lift is 630kg.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The visual contrast between the external lift controls and the control plate is low.
  • The visual contrast between the external lift control plate and the wall is low.
  • The clear door width is 80cm (2ft 7in).
  • The dimensions of the lift are 110cm x 144cm (3ft 7in x 4ft 9in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are low to moderate.
  • Comments View
    • A key card is required to enable the lift call button and is at a height of 100cm.
    • Key card access is allocated by Learning Support.

Other Floors

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located along the corridor from the entrance, through the doors on the left.
    • The stairs are approximately 13m from the entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on the ground floor.
      There is a manual, heavy, single door with a locked leaf to enter and exit the stairwell on the first and second floors.
    • The floors which are accessible by stairs are 0, 1, 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are moderate to good.
  • Comments View
    • There are refuge areas on the first and second floor landings.

Toilet with Adaptations (Right Transfer First Floor)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • The accessible toilet was out of use at the time of the survey.
    • This accessible toilet is located right out of the lift, along the corridor, then through the door on the right.
    • This accessible toilet is approximately 17m (18yd 1ft) from the lift.
    • There is step-free access into the accessible toilet, via lift.
    • This is a shared toilet.
    • A key is required for the accessible toilet.
    • The key is not a radar key.
    • The key can be obtained from the college as part of induction or ask at reception.
    • There is pictorial signage on or near the toilet door.
    • The visual contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 86cm.
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 145cm x 190cm (4ft 9in x 6ft 3in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 77cm (2ft 6in).
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with no lid) disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a cistern.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat visual contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 88cm (2ft 11in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 72cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 80cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 100cm (3ft 3in).
    • The contrast between the hand dryer and the wall is high.

Standard Toilet(s) (First Floor)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located right out of the lift, along the corridor, then through the door on the right.
    • There is step-free access into the toilet(s), via lift.
    • The standard toilet(s) is/are approximately 17m from the lift.
    • The visual contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.
    • The wash basin height in the standard female toilets is 81cm and the standard female toilets are shown in photographs 1 to 5.
      The wash basin height in the standard male toilets is 82cm and the standard male toilets are shown in photographs 6 to 13.