Skip to main content

South East Block

King's College London, Strand Campus, London, WC2R 2NE

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

Rooms and Spaces Links

Rooms and Spaces Links

Getting Here

Useful Information

Building Parking

  • The building does not have its own dedicated parking.

Entrance (Macadam Building)

  • Entrance View
    • This information is for the entrance located to the east of the block.
    • This entrance gives access to level 0.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped and stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 156cm.
  • Ramp/Slope View
    • The ramp/slope is located immediately beyond the doors.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.
    • The ramp/slope does not bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 8 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 19cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
  • Comments View
    • There are 8 steps from level 0 of the Macadam Building and 8 steps from the first floor.

Entrance (From King's Building to Floor -1)

  • Entrance View
    • This information is for the entrance located off the King's main corridor on floor -1.
    • This entrance gives access to the South East Block floor -1.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance, via lift.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width with a locked extension leaf.
    • The door(s) is/are heavy.
    • The width of the door opening is 85cm.

Ramp(s) or Slope(s) (From King's Building to Floor -1 Entrance)

  • Ramped/Sloped Level Change 1 View
    • There is a ramp/slope located in front of you on entering via the King's Building on floor -1.
    • The ramp/slope is used to access teaching rooms.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.
    • The ramp can be seen in photograph 1 and 2.
  • Ramped/Sloped Level Change 2 View
    • There is a ramp/slope located immediately to your right on entrance from the King's Building on floor -1.
    • The ramp/slope is used to access labs areas on the upper part of the floor -1 and lift.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a/are handrail(s) at the ramp.
    • The width of the ramp/slope is 130cm (4ft 3in).
    • The lighting levels at the ramp/slope are good.
    • The ramp can be seen in photographs 3, 4 and 5.

Entrance (From King's Building to Floor -2)

  • Entrance View
    • This information is for the entrance located off King's Building at level -1 to the rear of the main corridor.
    • This entrance gives access to South East Block floor -2.
    • The entrance area/door is not clearly signed.
    • There is stepped access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 105cm.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are heavy.
    • The width of the door opening is 140cm.
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 15+ step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 15cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.

Entrance (From King's Building to Floor 0)

  • Entrance View
    • This information is for the entrance located off the main corridor.
    • This entrance gives access to South East Block floor 0 (ground floor).
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 140cm.

Getting Around

  • Access View
    • There is step-free access throughout the majority of the building.
    • There is sloped/ramped access to all services when accessing the building via the King's Building floor -1 entrance.
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is vinyl.
    • There is some flooring in corridors/walkways which is shiny and could cause issues with glare or look slippery to some people.
    • There is high colour contrast between the walls and floor in all areas.
    • There are no seats/chairs at regular intervals.
    • The lighting levels are moderate to good.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is consistent throughout the building.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is not a hearing assistance system in the communal areas of the building.

Step(s)

  • Stepped Level Change 1 View
    • There is a/are step(s) located between the upper and lower areas of floor -1.
    • The step(s) is/are used to access the lower area of floor -1.
    • There is/are 4 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
    • There is a standard lift to overcome the step(s).
    • The steps can be seen in photograph 1.
  • Stepped Level Change 2 View
    • There is a/are step(s) located on floor -2.
    • The step(s) is/are used to access the breakout area.
    • There is/are 4 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.
    • The steps can be seen in photograph 2.

Other Floors (King's Building Entrance Level 0)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located in front of you on entering from the level 0 King's Building entrance.
    • The stairs are approximately 4m from the level 0 King's Building entrance.
    • The stairs are clearly visible from the entrance.
    • The floors which are accessible by the stairs are -2, -1, 0, 1, 2 and 3.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 16cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do not cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are good.

Lift

  • The lift is located within the South West Block Engineering Space.
  • The lift is clearly visible from the entrance.
  • The lift is approximately 16m (17yd 1ft) from the Kings Entrance floor -1.
  • The lift is a standard lift.
  • Does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are -1 and -2.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is medium.
  • The colour contrast between the external lift control plate and the wall is low.
  • The clear door width is 90cm (2ft 11in).
  • The dimensions of the lift are 140cm x 101cm (4ft 7in x 3ft 4in).
  • There are separate entry and exit doors in the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are good.

Accessible Toilet(s)

  • There is not an/are not accessible toilet(s) available.
  • The nearest accessible toilet(s) is/are located in the Quadrangle Building off King's Building floor -1 corridor.

Standard Toilet(s)

  • Standard toilet facilities are not available.
  • The nearest standard toilet(s) is/are located on level -1 off King's Building corridor.