Access Guide
Getting Here
-
By Road
View
- Gemini House is located in Cambridgeshire Business Park to the south of Ely.
Cambridgeshire Business Park is accessed from the A142 (the Ely Southern Bypass) via Angel Drove. - There is a large car park next to the building, however it does not have any designated parking bays for Blue Badge holders.
- Gemini House is located in Cambridgeshire Business Park to the south of Ely.
-
By Bus
View
- There is not a bus stop close to the building.
-
By Train
View
- Ely Station is approximately 700 metres from Gemini House.
Parking
-
Parking
View
- The venue does have a dedicated car park.
- The car park is located off Bartholemew's Walk.
- The car park type is open air/surface.
- The car park does not have a height restriction barrier.
- The car park does not have a barrier control system.
- The car park surface is tarmac and block paving.
- There is a/are Blue Badge parking bay(s) available.
- The Blue Badge bay(s) is/are clearly marked.
- There is/are 2 designated Blue Badge parking bay(s) within the car park.
- The dimensions of the designated Blue Badge parking bay(s) surveyed are 250cm x 480cm (8ft 2in x 15ft 9in).
- There is not a 120cm hatched zone around the Blue Badge parking bay(s).
- Parking spaces for Blue Badge holders do not need to be booked in advance.
- There is an overflow car park for staff and visitors.
-
Paying
View
- There are not parking charges for the car park.
-
Access from the Car Park
View
- The route from the car park to the entrance is accessible to a wheelchair user with assistance.
- Assistance may be required because there is / are slopes/ramps.
- The entrance is clearly visible from the car park.
- The surface on the approach to the entrance is block paving.
- There is no tactile paving on dropped kerbs between the car park and the entrance.
- The nearest designated Blue Badge parking bay is approximately 5m (5yd 1ft) from the main entrance.
Bus Stop(s) and Drop-off Point(s)
-
Bus Stop(s)
View
- There is not an onsite bus stop.
-
Drop-off Point(s)
View
- There is not a/are not clearly marked onsite drop-off point(s).
Outside Access (Main Entrance)
-
Entrance Details
View
- This information is for the entrance located at the front of the building.
- The entrance area/door is not clearly signed.
- There is ramped/sloped access at this entrance.
- There is not a canopy or recess which provides weather protection at this entrance.
- The entrance door(s) does not/do not contrast visually with its immediate surroundings.
- The main door(s) open(s) automatically (away from you).
- The door(s) is/are double width.
- The width of the door opening is 132cm.
- There is a small lip on the threshold of the entrance, with a height of 2cm or below.
- There is a second set of doors.
- The door(s) open(s) away from you (push).
- The door(s) is/are double width.
- The door(s) is/are heavy.
- The width of the door opening is 162cm.
-
Ramp/Slope Details
View
- The ramp/slope is located in front of the entrance.
- The gradient of the ramp/slope is slight.
- The ramp/slope is permanent.
- There is not a level landing at the top of the ramp/slope.
-
Comments
View
- There is an intercom to the right of the entrance.
- The height of the intercom ranges from 85cm to 102cm.
- The push to exit button is 93cm in height.
Getting Around The Building
-
Access
View
- There is step free access throughout the building via lift(s).
-
Circulation
View
- There are doors in corridors which have to be opened manually.
- There are corridors with a surface width of less than 120cm (excluding any permanent obstructions over a small distance).
- The type of flooring in walkways and corridors is carpet.
- Handrails with a rounded or oval profile are not provided in corridors.
- There is good colour contrast between the walls and floor in all areas.
- The lighting levels are good.
-
Signage
View
- Wayfinding signage is provided.
- The colour, design and typeface of signs is consistent throughout the building.
- Dementia friendly signage is not provided.
-
Safe Place(s)
View
- There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
-
Audio
View
- This venue does not play background music in public areas.
- There is not a hearing assistance system in the public areas of the building.
Other Floors
-
Stairs
View
- Signs indicating the location of the stairs are clearly visible from the entrance.
- There are manual, heavy, single doors to enter and exit the stairwell on the ground floor and on the first floor.
- The floors which are accessible by stairs are G, 1.
- There are 15+ steps between floors.
- The height of the step(s) is/are between the recommended 15cm and 18cm.
- The going of the step(s) is/are not between the recommended 30cm and 45cm.
- The steps are clearly marked.
- The steps do have handrails.
- The steps have a handrail on both sides.
- Handrails are at the recommended height (90cm-100cm).
- Handrails do cover the flight of stairs throughout its length.
- Handrails are easy to grip.
- Handrails do not extend horizontally beyond the first and last steps.
- There is a landing.
- Clear signs indicating the facilities on each floor of the building are not provided on landings.
- The lighting levels are moderate to good.
Lift
- There is a lift for public use.
- The lift is located just beyond the main entrance, to the left.
- Signs indicating the location of this lift are not clearly visible from the entrance.
- The lift is approximately 3m (3yd 10in) from the main entrance.
- The lift is a standard lift.
- Staff do not need to be notified for use of the lift.
- The floors which are accessible by this lift are G, 1.
- Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
- There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
- Lift doors do contrast visually with lift lobby walls.
- Lighting levels are at least 100 lux at floor level in the lift lobby.
- The external controls for the lift are not within 90cm - 110cm from the floor.
- The colour contrast between the external lift controls and the control plate is good.
- The colour contrast between the external lift control plate and the wall is poor.
- The clear door width is 80cm (2ft 7in).
- The dimensions of the lift are 107cm x 136cm (3ft 6in x 4ft 6in).
- There are not separate entry and exit doors in the lift.
- There is a mirror to aid reversing out of the lift.
- There is not a list of floor services available within the lift.
- The lift does not have a visual floor indicator.
- The lift does not have an audible announcer.
- The internal controls for the lift are within 90cm - 120cm from the floor.
- There is not a hearing loop system.
- The lift does have Braille markings.
- The lift does have tactile markings.
- The lighting level in the lift is moderate to good.
Accessible Toilet(s) (Ground Floor - Left Transfer)
- There is an/are accessible toilet(s) within this venue designated for public use.
-
Location and Access
View
- This accessible toilet is located immediately beyond the main entrance, to the left.
- This accessible toilet is approximately 2m (2yd 7in) from the main entrance.
- There is level access to this accessible toilet.
-
Features and Dimensions
View
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial signage on or near the toilet door.
- The door opens outwards.
- The door is locked by a twist lock.
- The door is light.
- The width of the accessible toilet door is 86cm (2ft 10in).
- The dimensions of the accessible toilet are 143cm x 230cm (4ft 8in x 7ft 7in).
- The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
- The toilet has a non-slip floor.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the left.
- The lateral transfer space is 73cm (2ft 5in).
- There is a dropdown rail on the transfer side.
- There is a vertical wall-mounted grab rail on the transfer side.
- There is a flush, however it is not on the transfer side.
- There is not a spatula type lever flush.
- There is not an emergency alarm.
- Disposal facilities are available in the toilet.
- There is a/are female sanitary and general waste (with no lid) disposal units.
- There is not a flashing fire alarm beacon within the toilet.
- There is not a/are not coat hook(s).
-
Position of Fixtures
View
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
- There is a vertical wall-mounted grab rail on the left hand side of the wash basin.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- There is not a standard shelf within the accessible toilet.
- There is not a colostomy changing shelf for standing users next to the toilet.
- There is not a mirror.
- The toilet does not have a backrest or a cistern.
- The height of the toilet seat above floor level is 45cm (1ft 6in).
- There is not a toilet roll holder.
- There is a wash basin.
- The wash basin can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The tap type is lever.
- There is not a mixer tap.
- There is a soap dispenser.
- The soap dispenser can be reached from seated on the toilet.
- The height of the soap dispenser is 100cm.
- There is a towel dispenser.
- The towel dispenser cannot be reached from seated on the toilet.
- The towel dispenser is not placed higher than 100cm (3ft 3in).
- The height of the towel dispenser is 95cm (3ft 1in).
- There is not a hand dryer.
-
Colour Contrast and Lighting
View
- The contrast between the external door and wall is good.
- The contrast between the internal door and wall is good.
- The contrast between the dropdown rail(s) and wall is fair.
- The contrast between the wall-mounted grab rail(s) and wall is fair.
- The toilet seat colour contrast is poor.
- The contrast between the walls and floor is poor.
- The lighting levels are good.
Accessible Toilet(s) (First Floor - Right Transfer)
- There is an/are accessible toilet(s) within this venue designated for public use.
-
Location and Access
View
- This accessible toilet is located on the first floor, opposite the Saunders Room.
- This accessible toilet is approximately 14m (15yd 11in) from the lift.
- There is level access to this accessible toilet.
- This is by lift.
-
Features and Dimensions
View
- This is a shared toilet.
- A key is not required for the accessible toilet.
- There is pictorial signage on or near the toilet door.
- The door opens outwards.
- The door is locked by a lever twist.
- The door is light.
- The width of the accessible toilet door is 88cm (2ft 11in).
- The dimensions of the accessible toilet are 243cm x 247cm (7ft 12in x 8ft 1in).
- The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
- The toilet has a non-slip floor.
- There is a lateral transfer space.
- As you face the toilet pan the transfer space is on the right.
- The lateral transfer space is 179cm (5ft 10in).
- There is a dropdown rail on the transfer side.
- There is a vertical wall-mounted grab rail on the transfer side.
- There is a flush on the transfer side.
- There is a spatula type lever flush.
- There is an emergency alarm.
- The emergency pull cord alarm is not fully functional.
- The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
- Disposal facilities are available in the toilet.
- There is a/are female sanitary and general domestic waste disposal units.
- There is a flashing fire alarm beacon within the toilet.
- There is a/are coat hook(s).
- There are coat hooks in the toilet at 115cm and 194cm from the floor.
-
Position of Fixtures
View
- There is a/are wall-mounted grab rail(s) available.
- As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
- There are vertical wall-mounted grab rails on both sides of the wash basin.
- There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
- There is not a standard shelf within the accessible toilet.
- There is not a colostomy changing shelf for standing users next to the toilet.
- There is a mirror.
- The mirror is not placed at a lower level or at an angle for ease of use.
- The toilet has a cistern.
- The height of the toilet seat above floor level is 48cm (1ft 7in).
- There is a toilet roll holder.
- The toilet roll holder can be reached from seated on the toilet.
- The toilet roll holder is not placed higher than 100cm (3ft 3in).
- The height of the toilet roll holder is 83cm (2ft 9in).
- There is a wash basin.
- The wash basin can be reached from seated on the toilet.
- The wash basin is not placed higher than 74cm (2ft 5in).
- The height of the wash basin is 71cm (2ft 4in).
- The tap type is lever.
- There is a mixer tap.
- There is a soap dispenser.
- The soap dispenser cannot be reached from seated on the toilet.
- The height of the soap dispenser is 95cm.
- There is a towel dispenser.
- The towel dispenser cannot be reached from seated on the toilet.
- The towel dispenser is not placed higher than 100cm (3ft 3in).
- The height of the towel dispenser is 89cm (2ft 11in).
- There is a hand dryer.
- The hand dryer cannot be reached from seated on the toilet.
- The hand dryer is not placed higher than 100cm (3ft 3in).
- The height of the hand dryer is 88cm (2ft 11in).
-
Colour Contrast and Lighting
View
- The contrast between the external door and wall is good.
- The contrast between the internal door and wall is good.
- The contrast between the dropdown rail(s) and wall is good.
- The contrast between the wall-mounted grab rail(s) and wall is good.
- The toilet seat colour contrast is good.
- The contrast between the walls and floor is good.
- The lighting levels are moderate to good.
-
Comments
View
- There is a wheel-in shower within this facility.
- There is a flip-down shower seat at a height of 51cm
- There are horizontal and vertical grab rails on the left side of the seat.
- There are dropdown rails on both sides of the seat.
- The controls for the shower are push button and lever mixer.
- The shower head can be hand held and is not permanently fixed.
Standard Toilet(s) (Ground Floor)
- Standard toilet facilities are available.
-
Access to Standard Female Toilet(s)
View
- The female toilet facilities that were surveyed are located just beyond the main entrance, to the right.
- The female toilet(s) is/are approximately 3m (3yd 10in) from the main entrance.
- Inside the venue, there is level access to the female toilet(s).
- There is pictorial signage on or near the toilet door.
- An ambulant toilet with wall mounted grab rails is not available.
- The tap type is lever.
- There is not a flashing fire alarm beacon within the toilets.
- Lighting levels are moderate to good.
-
Access to Standard Male Toilet(s)
View
- The male toilet facilities that were surveyed are located just beyond the main entrance, to the right.
- The male toilet(s) is/are approximately 6m (6yd 1ft) from the main entrance.
- Inside the venue, there is level access to the male toilet(s).
- There is pictorial signage on or near the toilet door.
- An ambulant toilet with wall mounted grab rails is not available.
- The tap type is lever.
- There is not a flashing fire alarm beacon within the toilets.
- Lighting levels are moderate to good.
Standard Toilet(s) (First Floor)
- Standard toilet facilities are available.
-
Access to Standard Female Toilet(s)
View
- The female toilet facilities that were surveyed are located on the first floor, opposite the lift.
- The female toilet(s) is/are approximately 2m (2yd 7in) from the lift.
- Inside the venue, there is level access to the female toilet(s).
- This is by lift.
- There is pictorial signage on or near the toilet door.
- An ambulant toilet with wall mounted grab rails is not available.
- The tap type is lever.
- There is not a flashing fire alarm beacon within the toilets.
- Lighting levels are moderate to good.
-
Access to Standard Male Toilet(s)
View
- The male toilet facilities that were surveyed are located on the first floor, to the left as you exit the lift.
- The male toilet(s) is/are approximately 4m (4yd 1ft) from the lift.
- Inside the venue, there is level access to the male toilet(s).
- This is by lift.
- There is pictorial signage on or near the toilet door.
- An ambulant toilet with wall mounted grab rails is not available.
- The tap type is lever.
- There is not a flashing fire alarm beacon within the toilets.
- Lighting levels are moderate to good.