Access Guide
Location of Room(s)
- Erasmus Darwin 161 - Lecture Theatre is/are located on the ground floor to the right.
- To view the AccessAble access guide for Erasmus Darwin please click here (new tab).
Lecture Theatre(s)
- Directional and locational signage for the lecture theatre(s) is available in upper and lower case lettering that is clearly visible.
- The corridor outside the lecture theatre(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
- There is step free access into the lecture theatre(s).
- The door opening width(s) is/are 75cm+ for the lecture theatre(s).
- The door(s) for the lecture theatre(s) is/are not push pad activated.
- There are designated spaces for wheelchair users within the lecture theatre(s).
- The designated spaces for wheelchairs users are located at the back.
- There is level access to the designated seating from an entrance.
- There is space for an assistance dog.
- There is not step free access to the speaker's area at the front of the lecture theatre(s).
- There is a ramp or step up to the speaker's area at the front.
- The height of the speaker's desk/table is 84cm.
- The speaker's desk/table is not height adjustable.
- There is not staggered seating within the lecture theatre(s).
- There is a hearing assistance system for the lecture theatre(s).
- There is not a visual fire alarm beacon in the lecture theatre(s).
- There is fixed furniture within the lecture theatre(s).
- There is sufficient space for a wheelchair user to manoeuvre within the lecture theatre(s).
- The clear floor space beneath tables in the lecture theatre(s) ranges between 69cm and 70cm.
- A height adjustable table/bench is not available.
- There are no chairs with armrests on both sides within the lecture theatre(s).
- Floor coverings in the lecture theatre(s) are not even.
Level Change (Speaker's Area)
- There is a ramp/slope to access this area/service.
- The ramp/slope does bypass the step(s).
- The ramp/slope is located on the right as you enter the room.
- The ramp/slope is permanent.
- There is not a level landing at the top of the ramp/slope.
- The ramp does not have handrails.
- The width of the ramp/slope is 109cm (3ft 7in).
- There is a/are step(s) to access this area/service.
- The step(s) is/are located at each end of the speaker's area.
- There is/are 1 step(s) to the area/service.
- The lighting levels at the step(s) are medium.
- The step(s) is/are not clearly marked.
- The step(s) is/are medium height (11cm - 17cm).
- There is not a/are not handrail(s) at the step(s).