Skip to main content
The new name for DisabledGo

Margam Building

Singleton Park Campus, Singleton Park, Swansea, Wales, SA2 8PP

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Overview

Getting Inside

  • The approach to the building is sloped.
  • The slope has a slight gradient.
  • The most accessible entrance surveyed was the main entrance at the front of the building.
  • This entrance gives access to the ground floor lobby.
  • There is step-free level access at the most accessible entrance.
  • There is 1 other entrance.
  • There is step-free access via slope at the other entrance.

Getting Around

  • Access View
    • There is step-free access between floors via lift.
    • There is step-free level access throughout walkways.
  • Circulation View
    • There are manual doors along circulation routes.
    • There is a high colour contrast between the walls and floor along the majority of circulation routes.
    • Some flooring is shiny.
    • There is background noise which varies depending on the time of day.
    • Wayfinding signage is provided.
    • The colour, design and typeface of signage is consistent throughout.
    • Seating available in the walkways includes: chairs without armrests and sofas.
    • Lighting levels were even at the time of the survey, with unshaded light sources.

Toilet and Changing Facilities

  • Toilet Facilities View
    • There are 4 toilets with adaptations.
    • The toilets with adaptations are located on the ground, second and third floors.
    • The transfer space varies between left and right in the toilets with adaptations.
    • Ambulant toilet facilities are located within the female standard toilet on the third floor.
    • Male step-free standard toilet facilities are located on the ground, first and third floors.
    • Female step-free standard toilet facilities are located the ground, second and third floors.

Entrance (Main)

  • This entrance is located at the front of the building.
  • The entrance area is clearly signed.
  • There is a canopy or recess which provides weather protection at the entrance.
  • There is step-free level access at the entrance.
  • There are double automatic doors.
  • The doors open by sliding.
  • The width of the opening is 151cm.
  • There is a small lip on the threshold of the opening.
  • The doors have a medium colour contrast.

Entrance (From The Wallace Building)

  • This entrance is located to the left hand side on the first floor of the Wallace Building.
  • The entrance area is not clearly signed.
  • There is step-free access via a slope at the entrance.
  • The slope has a steep gradient.
  • There is a single manual door.
  • The door is permanently held open.
  • There is a locked extension leaf.
  • The width of the opening is 70cm.
  • The door has a high colour contrast.

Lift

  • The lift surveyed is located to the left after you enter the building via the main entrance.
  • The distance from the main entrance is 12m.
  • The most accessible route to the lift has step-free level access.
  • There are no doors to open along the most accessible route.
  • Standard Lift View
    • The ground, first, second and third floors can be accessed by this lift.
    • The lift door has a high colour contrast.
    • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
    • The weight limit for the lift is 1000kg.
    • The external lift control buttons have tactile markings.
    • The control buttons have a medium colour contrast.
    • All of the external lift controls are at a suitable height for a wheelchair user.
    • The lift door opening width is 80cm.
    • The internal dimensions of the lift are 144cm (width) x 147cm (depth).
    • The internal lift control buttons have tactile markings.
    • The control buttons have a low colour contrast.
    • The majority of the internal controls are at a suitable height for a wheelchair user.
    • Internally the lift has: a visual floor indicator, an audible announcer, an intercom hearing assistance system and a mirror to aid reversing.
    • Lighting levels were even at the time of the survey, with unshaded light sources.

Stairs

  • The stairs are located straight ahead after you enter the building via the main entrance.
  • The ground, first, second and third floors can be accessed by these stairs.
  • There are double manual doors to access the stairwell.
  • There are handrails on both sides.
  • The handrails are not easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The steps are clearly marked.
  • The height of the steps is not between 15cm and 18cm.
  • The height of the highest step is 19cm.
  • The depth of the steps is not between 30cm-45cm.
  • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Ground Floor - Left Hand Transfer)

  • Location View
    • The toilet surveyed is located on the ground floor, to the left after you enter the building via the main entrance.
    • The distance from the main entrance is 17m.
  • Route View
    • The most accessible route to the toilet has step-free level access.
    • There is a manual door along the most accessible route.
  • Access View
    • There is step-free level access into the facility.
    • There is pictorial and written text signage on or near the door.
    • The door opens outwards and has a medium colour contrast.
    • The door is easy to open.
    • The width of the opening is 86cm.
    • The door has a locking handle.
    • Internally the door has a high colour contrast.
    • There is a grab rail on the internal door with a medium colour contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 153cm (width) x 267cm (depth).
    • There is room for a wheelchair user to manoeuvre.
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 79cm (from the side of the toilet pan).
    • There is a spatula flush for the toilet.
    • The flush is on the non-transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a high colour contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a high colour contrast.
    • There is a dropdown grab rail on the transfer side.
    • The dropdown grab rail has a high colour contrast.
    • The toilet seat is 49cm from the floor.
    • The toilet seat has a low colour contrast.
    • The toilet has a padded backrest.
    • The toilet roll holder can be reached when seated on the toilet.
    • The toilet roll holder has a medium colour contrast.
    • The toilet roll holder is 101cm from the floor.
    • The wash basin has a lever mixer tap.
    • The wash basin and tap can be reached when seated on the toilet.
    • The wash basin is 71cm from the floor.
    • There are vertical grab rails on both sides of the wash basin.
    • The wash basin grab rails have a high colour contrast.
    • There is a wall mounted soap dispenser.
    • The soap dispenser can be reached when seated on the toilet.
    • The soap dispenser has a high colour contrast.
    • The soap dispenser is 104cm from the floor.
    • There is a wall mounted towel dispenser.
    • The towel dispenser cannot be reached when seated on the toilet.
    • The towel dispenser has a high colour contrast.
    • The towel dispenser is 108cm from the floor.
    • There is not a hand dryer.
    • There is a pull cord emergency alarm, however it is not within 10cm from the floor.
    • There is no mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high colour contrast.
    • Lighting levels were even at the time of the survey.