Skip to main content

Chrystal Macmillan Building

The University of Edinburgh, Central Campus, 15a George Square, Edinburgh, EH8 9LD

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Introduction

  • Services include:.
  • Basement Floor - Seminar Rooms 4 - 6.
  • Ground Floor - Seminar Rooms 1 and 2, Reception and Café.
  • First - Sixth Floors - Meeting Rooms 1 - 6.
  • Sixth Floor - Head of School Office and the Staff Room.

Centrally Timetabled Spaces

Opening Times

  • Monday 09:00 - 17:00.
  • Tuesday 09:00 - 17:00.
  • Wednesday 09:00 - 17:00.
  • Thursday 09:00 - 17:00.
  • Friday 09:00 - 17:00.
  • Saturday Closed.
  • Sunday Closed.

Getting Here

  • By Road View
    • The Central Area is located on the south side in the city centre. Traffic congestion can be a problem, and parking is strictly controlled.
    • A number of University car parks are located in the Central Area. The Transport and Parking Office of the University of Edinburgh manages parking at the University. University car parks are for the use of permit holders only, and are subject to the university’s parking regulations. Permits are available for visitors to the university.
  • By Bus View
    • Buses from all over the city travel to the Central Area of the university. The University also provides a shuttle bus for staff and students between the Central Area and the King's Buildings. The majority of buses are operated by Lothian Buses. Up to the minute "real time" bus timetable information is now available at the majority of bus stops across the city. Information panels provided next to the majority of bus stops let you know when the next bus services will be arriving, or if there has been a delay.
  • By Train View
    • The Central Area of the university is 0.7 miles from Edinburgh Waverley Station. It should be noted that some of the walking routes may feature paths with steep gradients or steps given the landscape. Edinburgh has rail links throughout the UK. The East Coast mainline, which links Edinburgh and London King’s Cross, is the UK's fastest intercity railway: you can travel between the cities in around 4 hours. Or, if you prefer to travel overnight, a sleeper service runs between London Euston and Edinburgh Waverley 6 nights a week. There are great links to other cities too. The journey to Glasgow only takes 45 minutes, while York, Newcastle or Aberdeen can be reached in about 2 hours. All trains arrive at Waverley Station in the centre of the city, although some trains also stop at Haymarket, which is a smaller station in the West End.
  • Useful Links View

Useful Information

Site/Campus Car Park (George Square Lane - A and B Permit Holders)

  • Car Park View
    • The car park is located in George Square Lane.
    • The nearest building(s) to this car park is/are the Chrystal MacMillan Building and 16 -20 George Square.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are available.
    • The Blue Badge bay(s) is/are clearly marked.
    • There is/are 2 designated Blue Badge parking bay(s) within this car park.
    • The dimensions of the designated parking bay(s) are 560cm x 220cm (18ft 4in x 7ft 3in).
    • The dimensions of the designated bays do vary in size.
  • Charges and Restrictions View
    • This car park can be used by permit holders.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is sloped access to the car park from the Crystal MacMillan Building.
    • This car park is not clearly signposted from the Crystal MacMillan Building.
    • The nearest designated bay is 38m (41yd 1ft) from the Crystal MacMillan Building main entrance.
  • Comments View
    • This car parking area is essentially a private road in which permit holders can only park in the section belonging to the University.

Building Parking

  • The building does not have its own dedicated parking.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff and students within approximately 200m.
    • The name of the car park is George Square Lane Car Park.
    • The car park is located in George Square Lane.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • On Street Parking View
    • Clearly signed and/or marked on street Blue Badge parking bays are available (within approximately 50m of the building).
    • The dimensions of the marked Blue Badge bays are 265cm x 1200cm (8ft 8in x 39ft 4in).
    • The on street Blue Badge parking bay(s) is/are located on George Square.
    • Clearly signed and / or standard marked parking bays are available.
    • The on street standard parking bay(s) is/are located on George Square.
  • Drop Off Point View
    • There is not a designated drop off point.
  • Comments View
    • There is a mixture of resident permit and up to 4 hour pay and display on street parking on George Square.
    • These are marked areas as opposed to bays and may be restricted at times such as when the Fringe Festival is taking place.
    • George Square has a cobbled road surface.
    • There is a dropped kerb between the Blue Badge parking bay in George Square and the building entrances.
    • The dropped kerb does not have tactile paving and there is a short, steep incline on the footpath as shown in photograph 4.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located in George Square.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The main door(s) open(s) automatically (towards you).
    • The door(s) is/are push pad activated.
    • The door(s) is / are double.
    • The width of the door opening is 146cm (4ft 9in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) automatically (towards you).
    • The door(s) is/are push pad activated.
    • The door(s) is / are double.
    • The width of the door opening is 154cm (5ft 1in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • There is a ramp/slope at this entrance.
    • The ramp/slope is located leading up to the entrance from George Square.
    • The ramp or slope does bypass the step(s).
    • The ramp/slope gradient is easy.
    • The ramp is permanent.
    • There is a level landing at the top of the ramp.
    • The ramp does have handrails.
    • The handrails are on both sides.
  • Step(s) View
    • There is a / are step(s) at this entrance.
    • The step(s) is / are located leading up to the entrance from George Square.
    • There is / are 3 step(s) to access the entrance.
    • There is not tactile paving at the top and bottom of the step(s).
    • The step(s) is / are not clearly marked.
    • The step(s) is / are medium.
    • The steps do have handrails.
    • The handrails are on both sides.

Outside Access (Out of Hours Entrance)

  • Entrance View
    • This information is for the entrance located to the left of the main entrance.
    • There is ramped/sloped or stepped access at this entrance.
    • A key code is required for access at this entrance.
    • The card reader/lock is in a suitable position to allow wheelchair users to gain access.
    • The main door(s) open(s) automatically (towards you).
    • The door(s) is/are push pad activated when exiting.
    • The door(s) is / are single.
    • The width of the door opening is 100cm (3ft 3in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • There is a ramp/slope at this entrance.
    • The ramp/slope is located leading up to the entrance from George Square.
    • The ramp or slope does bypass the step(s).
    • The ramp/slope gradient is easy.
    • The ramp is permanent.
    • There is a level landing at the top of the ramp.
    • The ramp does have handrails.
    • The handrails are on both sides.
  • Step(s) View
    • There is a / are step(s) at this entrance.
    • The step(s) is / are located leading up to the entrance from George Square.
    • There is / are 3 step(s) to access the entrance.
    • There is not tactile paving at the top and bottom of the step(s).
    • The step(s) is / are not clearly marked.
    • The step(s) is / are medium.
    • The steps do have handrails.
    • The handrails are on both sides.

Outside Access (Basement Entrance)

  • Entrance View
    • This information is for the entrance located at the side of the building.
    • There is ramped/sloped access at this entrance.
    • A key code is required for access at this entrance.
    • The card reader/lock is not in a suitable position to allow wheelchair users to gain access.
    • The main door(s) open(s) automatically (towards you).
    • The door(s) is/are push pad activated.
    • The door(s) is / are single.
    • The width of the door opening is 114cm (3ft 9in).
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • There is a ramp/slope at this entrance.
    • The ramp/slope is located leading down to the entrance from the area outside the main entrance.
    • The ramp/slope gradient is moderate.
    • The ramp is permanent.
    • The ramp does have handrails.
    • The handrails are on both sides.
    • The width of the ramp is 118cm (3ft 10in).

Reception

  • The ground floor reception is located to the right as you enter the building via the main entrance.
  • The desk is 21m (22yd 2ft) from the main entrance.
  • The reception area is clearly visible from the entrance.
  • There is step free access to this reception area.
  • The lighting levels in the reception area are bright.
  • The reception desk/counter is high (110cm+).
  • The desk is staffed.
  • There is not a hearing assistance system.
  • Comments View
    • There is a lowered section with a knee recess but it is above the recommended height of 76cm.

Getting Around

  • Access View
    • There is step free access throughout the building.
    • There is/are 6 clearly marked step(s), with handrails on both sides, for access to the raised section of the ground floor.
    • The step(s) is/are medium (11cm - 17cm).
    • There is an easy ramp, with handrails on both sides, for access to the raised section of the ground floor.
    • The width of the ramp is 120cm (3ft 11in).
    • The ramp or slope does bypass the step(s).
    • Photographs 1 and 2 show the level change to the raised section of the ground floor.
    • There are not doors in corridors which have to be opened manually.
  • Getting Around View
    • There is clear signage for building facilities/areas in the foyer/reception area.
    • There is clearly written directional signage at key points of circulation routes.
    • There is some flooring in corridors with a very shiny finish which could cause issues with glare or be perceived as slippery.
    • There is good colour contrast between the walls and floor in all areas.
    • The lighting levels are varied.
    • This building does not play background music.
    • There is not a hearing assistance system.

Eating and Drinking (Ground Café)

  • The following information is for the cafe.
  • Full table service is not available.
  • Food or drinks are ordered from the service counter.
  • Food or drinks can be brought to the table.
  • There is not a lowered section at the counter.
  • No tables are permanently fixed.
  • No chairs are permanently fixed.
  • No chairs have armrests.
  • The nearest table is 3m (3yd 10in) from the main entrance.
  • The distance between the floor and the lowest table is 66cm (2ft 2in).
  • The distance between the floor and the highest table is 99cm (3ft 3in).
  • The standard height for tables is 66cm.
  • There is ample room for a wheelchair user to manoeuvre.
  • Plastic / takeaway cups are available.
  • Plastic / takeaway cutlery is available.
  • Drinking straws are available.
  • Menus are wall only.
  • Picture menus are not available.
  • Menus are not clearly written.
  • Menus are presented in contrasting colours.
  • The type of food served here is hot and cold snacks as displayed.

Other Floors (Staircase 1)

  • Steps View
    • The floors which are accessible by stairs are B-G-1-2-3-4-5-6.
    • There are 15+ steps between floors.
    • There are manual, heavy, single doors to access the stairwell on all floors.
    • The lighting levels are medium.
    • The steps are clearly marked.
    • The steps are medium (11cm - 17cm).
    • The steps do have handrails.
    • The steps have a handrail on the left going up.
    • There is a landing.

Other Floors (Staircase 2)

  • Steps View
    • The floors which are accessible by stairs are B-G-1-2-3-4-5-6.
    • There are 15+ steps between floors.
    • There are manual, heavy, single doors to access the stairwell on all floors.
    • The lighting levels are medium.
    • The steps are clearly marked.
    • The steps are medium (11cm - 17cm).
    • The steps do have handrails.
    • The steps have a handrail on both sides.
    • There is a landing.

Other Floors (Staircase 3)

  • Steps View
    • The floors which are accessible by stairs are B-G-1.
    • There are 15+ steps between floors.
    • The lighting levels are bright.
    • The steps are clearly marked.
    • The steps are medium (11cm - 17cm).
    • The steps do have handrails.
    • The steps have a handrail on both sides.
    • There is a landing.

Lift (1)

  • There is a lift for public use.
  • The lift is located off the main foyer.
  • The lift is a standard lift.
  • The floors which are accessible by this lift are B-G-1-2-3-4-5-6.
  • Wall mounted information boards are not provided at lift landings.
  • The lift is approximately 17m (18yd 1ft) from the main entrance.
  • Staff do not need to be notified for use of the lift.
  • The clear door width is 80cm (2ft 7in).
  • The dimensions of the lift are 105cm x 140cm (3ft 5in x 4ft 7in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The lift does not have a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The controls for the lift are within 90cm - 120cm from the floor.
  • The lighting level in the lift is medium.

Lift (2)

  • There is a lift for public use.
  • The lift is located on the raised section at the rear of the ground floor.
  • The lift is a standard lift.
  • The floors which are accessible by this lift are B-G-1-2-3-4-5-6.
  • Wall mounted information boards are not provided at lift landings.
  • There are manual, heavy, single doors to access the lift lobby on all floors.
  • The lift is approximately 62m (67yd 2ft) from the main entrance.
  • Staff do not need to be notified for use of the lift.
  • The clear door width is 82cm (2ft 8in).
  • The dimensions of the lift are 106cm x 210cm (3ft 6in x 6ft 11in).
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The lift does not have a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The controls for the lift are within 90cm - 120cm from the floor.
  • The lighting level in the lift is medium.

Reception (First Floor - Graduate School Office)

  • The graduate school office is located on the first floor.
  • The desk is 25m (27yd 1ft) from the lift (1).
  • Clear signage for the reception area is visible from the lift.
  • There is step free access to this reception area, via lift.
  • The lighting levels in the reception area are bright.
  • The reception desk/counter is medium height (77cm - 109cm).
  • There is a low section of the counter (76cm or below) available.
  • There is a clear knee recess beneath the low counter.
  • The desk is not staffed.
  • There is a bell to attract attention.
  • The bell is at a suitable height for a wheelchair user.
  • There is not a hearing assistance system.
  • Comments View
    • The office is accessed via a single width door which opens away from you (push).
    • The door is heavy.
    • The width of the door opening is 88cm.

Opening Times (First Floor - Graduate School Office)

  • Monday 09:30 - 12:30.
  • Monday 13:30 - 16:00.
  • Tuesday 13:30 - 16:00.
  • Wednesday 09:30 - 12:30.
  • Wednesday 13:30 - 16:00.
  • Thursday 09:30 - 12:30.
  • Thursday 13:30 - 16:00.
  • Friday 13:30 - 16:00.
  • Saturday Closed.
  • Sunday Closed.

Link to West Wing - Fifth Floor

  • There are link corridors connecting the Chrystal MacMillan Building to the adjoining William Robertson Wing on the ground floor up to the fifth floor, off stairwell 2.
  • On the fifth floor there is level access to a single width door which has an extension leaf with a combined opening width of 144cm.
  • The door opens towards you (pull), and is heavy.
  • Immediately beyond the entrance there are 6 medium (15cm) steps with handrails on both sides.
  • The steps are clearly marked.
  • The door leading into the William Robertson Wing requires a keycard for access.
  • The height of the keycard controls are 113cm - 118cm.
  • There is stepped access into the William Robertson Wing on other floors although platform lifts are provided on floors 1 and 3.

Accessible Toilet (Ground Floor - Foyer)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 23m (25yd 6in) from the main entrance.
    • This accessible toilet is located off the ground floor foyer.
    • There is level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 218cm x 236cm (7ft 2in x 7ft 9in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 130cm (4ft 3in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 105cm (3ft 5in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Ground Floor - Stair 2)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 62m (67yd 2ft) from the main entrance.
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the raised section of the ground floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 180cm x 190cm (5ft 11in x 6ft 3in).
    • Floor manoeuvring space is not clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 125cm (4ft 1in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 110cm (3ft 7in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Basement Floor)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 12m (13yd 4in) from the lift (1).
    • This accessible toilet is located on the basement floor, next to Seminar Room 4.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 86cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 170cm x 220cm (5ft 7in x 7ft 3in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 100cm (3ft 3in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 115cm (3ft 9in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (First Floor - Stair 1)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 9m (9yd 2ft) from the lift (1).
    • This accessible toilet is located on the first floor next to Meeting Room 1.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 268cm x 160cm (8ft 10in x 5ft 3in).
    • Floor manoeuvring space is not clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 200cm (6ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 50cm (1ft 8in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 112cm (3ft 8in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (First Floor - Stair 2)

  • There are accessible toilet facilities within this venue.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 5m (5yd 1ft) from the lift (2).
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the first floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 158cm x 190cm (5ft 2in x 6ft 3in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 115cm (3ft 9in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Second Floor - Stair 1)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the lift (1).
    • This accessible toilet is located on the second floor main corridor, opposite Stair 1 / Lift 1.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 178cm x 290cm (5ft 10in x 9ft 6in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 110cm (3ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 110cm (3ft 7in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are medium.

Accessible Toilet (Second Floor - Stair 2)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 5m (5yd 1ft) from the lift (2).
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the second floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 156cm x 185cm (5ft 1in x 6ft 1in).
    • Floor manoeuvring space is not clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 106cm (3ft 6in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Third Floor - Stair 1)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the lift (1).
    • This accessible toilet is located on the third floor main corridor, opposite Stair 1 / Lift 1.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 190cm x 300cm (6ft 3in x 9ft 10in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 120cm (3ft 11in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 118cm (3ft 10in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are medium.

Accessible Toilet (Third Floor - Stair 2)

  • There are accessible toilet facilities within this venue.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 5m (5yd 1ft) from the lift (2).
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the second floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 158cm x 180cm (5ft 2in x 5ft 11in).
    • Floor manoeuvring space is not clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 116cm (3ft 10in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Fourth Floor - Stair 1)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the lift (1).
    • This accessible toilet is located on the fourth floor main corridor opposite Stair 1 / Lift 1.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 175cm x 295cm (5ft 9in x 9ft 8in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 110cm (3ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 118cm (3ft 10in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is good.
    • The contrast between the walls and floor is good.
    • The lighting levels are medium.

Accessible Toilet (Fourth Floor - Stair 2)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 5m (5yd 1ft) from the lift (2).
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the fourth floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 160cm x 190cm (5ft 3in x 6ft 3in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 117cm (3ft 10in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Fifth Floor - Stair 1)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the lift (1).
    • This accessible toilet is located on the fifth floor main corridor, opposite Stair 1 / Lift 1.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 175cm x 290cm (5ft 9in x 9ft 6in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 110cm (3ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is fully functional.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 110cm (3ft 7in).
    • There is a toilet roll holder.
    • The toilet roll holder cannot be reached from seated on the toilet.
    • The toilet roll holder is placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 108cm (3ft 7in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are medium.

Accessible Toilet (Fifth Floor - Stair 2)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 5m (5yd 1ft) from the lift (2).
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the fifth floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 158cm x 190cm (5ft 2in x 6ft 3in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 117cm (3ft 10in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Accessible Toilet (Sixth Floor - Stair 1)

  • There is an/are accessible toilet(s) within this venue designated for public use.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 8m (8yd 2ft) from the lift (1).
    • This accessible toilet is located on the sixth floor main corridor opposite Stair 1 / Lift 1.
    • There is level access to this accessible toilet.
    • This is by lift.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens inwards and outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 87cm (2ft 10in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 188cm x 290cm (6ft 2in x 9ft 6in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 120cm (3ft 11in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is not within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on both sides.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is not a hand dryer.
    • There is a towel dispenser.
    • The towel dispenser cannot be reached from seated on the toilet.
    • The towel dispenser is placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 110cm (3ft 7in).
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are medium.

Accessible Toilet (Sixth Floor - Stair 2)

  • There are accessible toilet facilities within this venue.
  • Location and Access View
    • The toilet is not for the sole use of disabled people.
    • There is pictorial signage on or near the toilet door.
    • This accessible toilet is approximately 5m (5yd 1ft) from the lift (2).
    • This accessible toilet is located in the Stair 2 / Lift 2 lobby on the sixth floor.
    • There is not level access to this accessible toilet.
  • Features and Dimensions View
    • This is a unisex toilet.
    • A key is not required for the accessible toilet.
    • The door opens outwards.
    • The door is locked by a twist lock.
    • The width of the accessible toilet door is 84cm (2ft 9in).
    • The door is heavy.
    • The dimensions of the accessible toilet are 158cm x 190cm (5ft 2in x 6ft 3in).
    • Floor manoeuvring space is clear in the accessible toilet.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • There is a dropdown rail on the transfer side.
    • There is a flush on the transfer side.
    • The tap type is lever.
    • There is a mixer tap.
    • There is an emergency pull cord alarm in the cubicle.
    • The emergency pull cord alarm is not fully functional.
    • The alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • Disposal facilities are not available in the cubicle.
    • There is a/are coat hook(s).
    • The coat hook is within 120cm (3ft 11in) from floor level.
  • Position of Fixtures View
    • Wall-mounted grab rails are available.
    • As you face the toilet the wall-mounted grab rails are on the right.
    • There is not a shelf within the accessible toilet.
    • There is a mirror.
    • Mirrors are not placed at a lower level or at an angle for ease of use.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • There is a hand dryer.
    • The hand dryer cannot be reached from seated on the toilet.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 117cm (3ft 10in).
    • There is not a towel dispenser.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • There is a wash basin.
    • The wash basin can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
  • Colour Contrast and Lighting View
    • The contrast between the internal door and wall is good.
    • The contrast between the external door and wall is good.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the dropdown rail(s) and wall is poor.
    • The toilet seat colour contrast is poor.
    • The contrast between the walls and floor is good.
    • The lighting levels are bright.

Standard Toilet(s) (Ground Floor)

  • Location of Standard Toilet(s) View
    • There are male and female standard toilets facilities on all floors.
  • Standard Toilet Surveyed View
    • A male standard toilet was surveyed.
    • The toilet surveyed is located off the ground floor foyer.
    • There is a female standard toilet in the same location.
    • There is step free access to the standard toilet(s) surveyed from the entrance.
    • The standard toilet surveyed is approximately 21m from the main entrance.
    • There is not a/are not cubicle(s) suitable for ambulant disabled people in the standard toilet(s) surveyed.
    • Lighting levels in the standard toilet surveyed are varied.
  • Comments View
    • Standard toilet facilities have similar specifications on all floors.
    • There are no shared sex standard toilets.
    • There are no cubicles suitable for ambulant disabled people in any standard toilet facilities.

Standard Shower

  • Shower facilities are available.
  • The shower(s) surveyed is/are located on the basement floor next to the toilet facilities.
  • There is level access to the services from the shower facilities.
  • Comments View
    • There are 3 identical shower cubicles in this location.
    • The shower trays are accessed via a shallow step.
    • The shower heads are height adjustable.
    • There are no handrails in the shower cubicles.