Overview

Getting Inside

  • The approach to the building is step-free.
  • The Art, Design and Media Centre has 2 entrances. Both entrances provide step-free level access to the ground floor. There are double automatic doors at both entrances.
  • The main entrance is signed as Art, Design and Media Centre.
    The side entrance is not signed.
  • The main entrance provides step free access to the ground floor.

Getting Around

  • There is step-free level access to the ground floor.
  • For step-free access to the first floor, you would need to use the lift in Vernon Tower and take the link corridor back through to the Arts Centre.
  • Floor surfaces along all circulation routes are hard and smooth, with some having a shiny finish.
  • There are resting areas in some circulation and lobby areas with a mixture of seating.
  • There is no wayfinding signage available in the building.
  • There are not manual doors in any circulation corridors.

Toilet and Changing Facilities

  • Toilet Facilities View
    • There are 2 toilets with adaptations.
    • Toilets with adaptations are located on the ground and first floor, off the main corridor.
    • All toilets with adaptations have a right hand transfer space.
    • The male and female step-free toilet facilities are located on the ground and first floor, off the main corridor.

Entrance

  • This entrance is located at the front right of the building.
  • The approach to the entrance has uneven surfaces.
  • The entrance area is clearly signed.
  • There is not a canopy or recess which provides weather protection at the entrance.
  • There is step-free level access at the entrance.
  • There are double automatic doors at this entrance.
  • The doors open by sliding.
  • The width of the opening is 174cm.
  • There is a small lip on the threshold of the opening.
  • The doors have a low visual contrast.
  • There is a second set of double automatic doors .
  • The second set of doors open by sliding.
  • The width of the opening is 175cm.
  • There is a small lip on the threshold of the opening.
  • The second set of doors have a low visual contrast.

Main Stairs

  • The stairs surveyed are located on the right side of the building.
  • The ground and first floors can be accessed by these stairs.
  • There are 17 steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are not easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails extend horizontally beyond the first and last step.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 17cm.
  • The depth of the steps is not between 30cm and 45cm.
  • Lighting levels vary due to the size of the space.

Stairs (Left Side)

  • The stairs surveyed are located on the left side of the building giving access to the link corridor to Vernon Tower.
  • There is a single manual door to access the stairwell.
  • The ground and first floors can be accessed by these stairs.
  • There are 17 steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are not easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 16cm.
  • The depth of the steps is not between 30cm and 45cm.
  • Lighting levels were uneven at the time of the survey, with pools of light and shade.

Toilet with Adaptations (Ground Floor - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the ground floor, at the rear right of the building.
    • The distance from the main entrance is 21m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 91cm.
    • The door has a locking handle.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 148cm (width) x 188cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
    • The lateral transfer space is 80cm (from the side of the toilet pan).
    • There is a spatula flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a high visual contrast.
    • There are vertical grab rails on both sides of the toilet.
    • The vertical grab rails have a high visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a high visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a high visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a high visual contrast.
    • The toilet roll holder is 124cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 73cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a high visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 112cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a high visual contrast.
    • The hand dryer is 95cm from the floor.
    • There is no emergency alarm.
    • There is a full length mirror.
    • The cubicle has a nappy/incontinence items bin and a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were uneven at the time of the survey, with pools of light and shade and unshaded light sources.