Skip to main content
The new name for DisabledGo

Whitworth Centre

Stockport College, Wellington Road South, Stockport, SK1 3UQ

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Overview

Getting Inside

  • The approach to the building is step-free and level.
  • The Whitworth Centre has 1 entrance. The entrance provides step-free level access to the ground floor. There is a single automatic door at this entrance.
  • The entrance is signed Whitworth Centre.

Getting Around

  • There is step-free level access throughout the building on all floors.
  • Floor surfaces along all circulation routes are hard and smooth, with some having a shiny finish.
  • There are no resting areas in the circulation or lobby areas.
  • Wall mounted wayfinding signage is provided throughout the building.
  • There are manual doors along circulation routes throughout the building.

Toilet and Changing Facilities

  • Toilet Facilities View
    • There are 2 toilets with adaptations.
    • The toilet with adaptations is located on each floor, off the main corridor.
    • The transfer space varies between left and right in the toilets with adaptations.
    • The gender neutral step-free toilet facilities are located on the ground floor off the main corridor.

Entrance

  • This entrance is located at the front right of the building.
  • The entrance area is clearly signed.
  • There is step-free level access at the entrance.
  • There is a single automatic door at this entrance.
  • The door opens towards you.
  • The door has a low visual contrast.

Lift

  • The lift surveyed is located on the right side of the building.
  • The distance from the entrance is 9m.
  • The most accessible route to the lift has step-free level access.
  • The ground, first, second, third and fourth floors are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a medium visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 90cm.
  • The internal dimensions of the lift are 109cm (width) x 202cm (depth).
  • The internal lift control buttons have tactile markings and a low visual contrast.
  • All of the internal lift controls are at a suitable height for a wheelchair user.
  • Internally the lift has: a mirror to aid reversing, a visual floor indicator and an audible announcer.
  • Lighting levels were low at the time of the survey.
  • There are other lifts available at this location which vary in size.
  • Key card reader 122cm.

Stairs

  • The stairs surveyed are located at the front right of the building.
  • There is a single manual door to access the stairwell.
  • The ground, first, second and third floors can be accessed by these stairs.
  • There are 20+ steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails extend horizontally beyond the first and last step.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 17cm.
  • The depth of the steps is not between 30cm and 45cm.
  • Lighting levels vary due to the size of the space.

Toilet with Adaptations (Ground Floor - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the ground floor, off the main corridor.
    • The distance from the entrance is 8m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 88cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 150cm (width) x 222cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
    • The lateral transfer space is 86cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There are vertical grab rails on both sides of the toilet.
    • The vertical grab rails have varying visual contrasts.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a high visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low visual contrast.
    • The toilet roll holder is 88cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 68cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a high visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 125cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 98cm from the floor.
    • There is no emergency alarm.
    • There is no mirror.
    • There is no shelf.
    • The cubicle has a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were uneven at the time of the survey, with pools of light and shade and unshaded light sources.

Toilet with Adaptations (Fourth Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the fourth floor, to the left as you exit the lift.
    • The distance from the lift is 2m.
    • The most accessible route to the toilet has step-free level access and a lift.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 89cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 150cm (width) x 221cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 83cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There are vertical grab rails on both sides of the toilet.
    • The vertical grab rails have varying visual contrasts.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a high visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low visual contrast.
    • The toilet roll holder is 100cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 124cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 100cm from the floor.
    • There is no emergency alarm.
    • There is no mirror.
    • There is no shelf.
    • The cubicle has a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were uneven at the time of the survey, with pools of light and shade and unshaded light sources.
    • There is a key card reader at a height of 123cm from the floor.
      There is a door release at a height of 120cm from the floor.