Skip to main content
The new name for DisabledGo

Derhill

University of Bath, Claverton Down, Bath, BA2 7AY

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Accommodation Summary

  • Parking and Transport View
    • The accommodation shares another buildings parking facilities.
    • No secure parking is available.
    • There is a designated drop off point.
  • Residence Information View
    • This residence is made up of single building, consisting of 5 identical Houses. buildings.
    • The residence surveyed was House 2.
  • Accessible Accommodation Information View
    • The accommodation has 17 rooms in total.
    • There is not an/are not accessible room(s) within the accommodation.
  • Standard Accommodation Information View
    • There is standard accommodation on the ground floor.
    • Ground floor accommodation does not have level access.
    • There are standard rooms on other floors.
    • The other floors cannot be accessed by lift.
    • Standard accommodation has shared bathrooms with stepped shower cubicles.
    • There is not an/are not adjoining room(s) available for the standard room(s).
  • Amenities and Communal Facilities View
    • There is a convenience store within approximately 200 metres of the residence.
    • The communal facilities for the accommodation surveyed include; a kitchen and a dining area.

Getting Here

Useful Information

Building Parking

  • The building does not have its own dedicated parking.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff, students and visitors within approximately 200m.
    • The name of the car park is Brendon Court Blue Badge Parking, Car Park K.
    • The car park is located off Quarry Road, and to the rear of Wolfson accommodation.

Site/Campus Car Park (Brendon Court Blue Badge Parking)

  • Car Park View
    • The car park is located off Quarry Road adjacent to Brendon Court and 1 West North.
    • The nearest building(s) to this car park is/are Brendon Court and 1 West North.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are available.
    • The Blue Badge bay(s) is/are clearly marked and signposted.
    • There is/are 4 designated Blue Badge parking bay(s) within this car park.
    • The dimensions of the designated parking bay(s) are 230cm x 432cm.
    • The Blue Badge parking bays have a marked zone to both sides but not at the rear.
    • The marked zone is 120cm wide.
    • The dimensions of the designated bays do not vary in size.
  • Charges and Restrictions View
    • This car park can be used by Blue Badge holders.
    • There are no parking charges that apply on the day.
    • Signs are provided to give information on parking charges/restrictions.
    • Signs are clearly presented.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are clearly signposted from this car park.
    • There is not a campus map available within the car park.
    • The nearest designated bay is 35m (38yd 10in) from the Brendon Court central entrance.
    • One of the 4 bays illustrated is a single Blue Badge parking bay on the opposite side of Quarry Road, adjacent to building 1 West North, it is 7 meters from 1 West North entrance.

Site/Campus Car Park (Car Park K)

  • Car Park View
    • The car park is located at the north end of Brandon Walk.
    • The nearest building(s) to this car park is/are Wolfson accommodation block.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are not available.
  • Charges and Restrictions View
    • This car park can be used by permit holders.
    • Parking charges apply to visitors only.
    • Signs are provided to give information on parking charges/restrictions.
    • Signs are clearly presented.
    • Payment can be made by phone.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is not step free access from this car park.
    • Buildings are not clearly signposted from this car park.
    • There is not a campus map available within the car park.
    • The nearest designated bay is 10m (10yd 2ft) from the Wolfson east entrance.

Outside Access (Front Entrance House 2)

  • Entrance View
    • This information is for the entrance located at front of the building.
    • This entrance gives access to House 2, kitchen 1.
    • The entrance area/door is not clearly signed.
    • This entrance is signed with '2'.
    • There is ramped/sloped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • There is a dark mat or floor marking at this entrance that might be perceived as a hole.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 125cm.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 78cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is not a level landing at the top of the ramp/slope.
    • There is not a/are not handrail(s) at the ramp.

Outside Access (Rear Entrance House 2)

  • Entrance View
    • This information is for the entrance located at the rear of the building.
    • This entrance gives access to the stairwell.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'Derhill House 2 Rooms 1 - 19'.
    • There is stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 125cm.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 78cm.
  • Step(s) View
    • The step(s) is/are located at the door frame.
    • There is/are 1 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 7cm.

Step(s) (Kitchen/Dining Area)

  • Stepped Level Change 1 View
    • There is a/are step(s) located to the rear and left of the stairwell lobby.
    • The step(s) is/are used to access entrance to kitchen dining area.
    • There is/are 6 step(s).
    • The step(s) is/are clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • The lighting levels at the step(s) are good.

Entrance (Kitchen/Dining Area)

  • Entrance View
    • This information is for the entrance located in the stairwell lobby.
    • This entrance gives access to the kitchen dining area.
    • The entrance area/door is not clearly signed.
    • There is stepped access at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 70cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 70cm.
    • There is a door stop that prevents the second door opening completely, access is therefore only 59cm at that point.

Kitchen/Dining Area

  • The kitchen/dining area is accessed by a single door with an opening width of less than 75cm.
  • Lowered work surfaces are not available.
  • The height of the lowest work surface is 90cm.
  • The kitchen does not have an unobstructed floor space of at least 150cm × 150cm.
  • There are some low level cupboards.
  • There are easy to grip handles or taps for cupboards, the freezer and the sink.
  • The height of the dining table is 68cm.
  • There is bench seating only at the dining table.

Other Floors

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located immediately in front of the entrance.
    • The stairs are approximately 4m from the rear entrance.
    • The stairs are clearly visible from the entrance.
    • The floors which are accessible by the stairs are Level 1, 2, 3 and 4.
    • There are 14 steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.

Getting Around

  • Access View
    • There is not step-free access throughout the building .
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • There are corridors/walkways with a surface width of less than 120cm (excluding any permanent obstructions over a small distance).
    • The type of flooring in corridors/walkways is vinyl.
    • There is high colour contrast between the walls and floor in the majority of corridors/walkways.
    • The lighting levels are moderate to good.
  • Signage View
    • Wayfinding signage is not provided.