Skip to main content
The new name for DisabledGo

Large Lecture Theatre

Department of Geography (Geography School), University of Cambridge, Downing Site, Cambridge, CB2 1QB

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Access To

  • The Large Lecture Theatre is located on the Lower Ground Floor of the Geography School, to the right and ahead as you exit the Accessible Entrance Platform Lift.
  • View information on Department of Geography (Geography School) (opens new tab) .
  • The most accessible route has step-free level access, a platform lift, manual doors and automatic doors.
  • There is written text signage on or near the entrance.
  • There is step-free level access via lift into the lecture theatre.
  • There are 3 steps with a handrail on the right going up.
  • The handrail is easy to grip.
  • The handrail covers the flight of stairs throughout its length.
  • The handrail does not extend horizontally beyond the first and last step.
  • The steps are clearly marked.
  • The height of the steps is between 15cm and 18cm.
  • The height of the highest step is 16cm.
  • The depth of the steps is not between 30cm and 45cm.
  • The platform lift bypasses the steps into the lecture theatre, providing step-free level access.
  • There are double automatic doors which open towards you.
  • The push pad for the automatic doors is at a height of 85cm.
  • The width of the opening is 136cm.
  • The doors have a low visual contrast.
  • There is a push pad or push button to exit at a height of 85cm.
  • There are a second set of double manual doors which open towards you.
  • One of the doors was locked at the time of the survey.
  • The width of the opening is 64cm.
  • The second set of doors have a high visual contrast.

Teaching

  • This is a lecture theatre.
  • There is step-free level access to the speaker’s area and front row only.
  • The following areas have stepped access: all seating beyond the first row.
  • There is room for a wheelchair user to manoeuvre (150cm x 150cm).
  • There is not a hearing assistance system.
  • Some flooring is patterned.
  • Floor coverings are not even and could potentially cause a trip hazard.
  • The walls and floor visual contrast varies between low and high.
  • Lighting levels vary due to the size of the space.
  • There is tiered seating with no handrails at the steps.
  • There are no designated spaces for wheelchair users.
  • There is not space for an assistance dog to rest.
  • Seating available in the room includes: chairs without armrests and benches.
  • Furniture available in the room includes: tables and desks.
  • Some chairs and tables are fixed.
  • Some surface heights are suitable for wheelchair users.
  • The clear underside space of some surfaces is suitable for wheelchair users.
  • The height of the speaker's desk/table is 91cm.
  • The speaker's desk/table is not height adjustable.
  • The height of the lectern is 115cm.
  • The lectern is not height adjustable.
  • This room has a projector screen and a blackboard.
  • There are cable coverings as trip hazards at the front of the lecture theatre.

Lift (Large Lecture Theatre)

  • The lift surveyed is located to the right of the steps into the Large Lecture Theatre.
  • This lift is a platform lift.
  • The distance from the Accessible Entrance is 10m.
  • The most accessible route to the lift has step-free level access, a platform lift and automatic doors.
  • The lift door has a low visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a high visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 78cm.
  • The internal dimensions of the lift are 104cm (width) x 134cm (depth).
  • The internal lift control buttons have tactile markings and a high visual contrast.
  • Some of the internal lift controls are at a suitable height for a wheelchair user.
  • The button needs to be pressed constantly when in use.
  • Internally the lift has: a separate door to exit.
  • Lighting levels vary due to the size of the space.

Toilet with Adaptations (Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located to the left and ahead as you exit the Large Lecture Theatre.
    • The distance from the Large Lecture Theatre is 13m.
    • The most accessible route to the toilet has step-free level access and a platform lift.
    • There is step-free level access via lift into the facility.
    • There are 3 steps with a handrail on the left going down.
    • The handrail is easy to grip.
    • The handrail covers the flight of stairs throughout its length.
    • The handrail does not extend horizontally beyond the first and last step.
    • The steps are clearly marked.
    • The height of the steps is between 15cm and 18cm.
    • The height of the highest step is 16cm.
    • The depth of the steps is not between 30cm and 45cm.
    • The Large Lecture Theatre platform lift bypasses the steps.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a low visual contrast.
    • The width of the door opening is 89cm.
    • The door has a twist lock.
    • Internally the door has a low visual contrast.
    • There is not a grab rail on the internal door .
  • Dimensions and Features View
    • The dimensions of the cubicle are 145cm (width) x 230cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet.
    • The lateral transfer space on the right is 82cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a high visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a high visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a high visual contrast.
    • The toilet seat is 48cm from the floor.
    • The toilet seat has a high visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low visual contrast.
    • The toilet roll holder is 88cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a high visual contrast.
    • There is a wall mounted soap dispenser which cannot be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 92cm from the floor.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 90cm from the floor.
    • There is a pull cord emergency alarm but it was tied up at the time of the survey.
    • There is a mirror.
    • There is no shelf.
    • The cubicle has a sanitary bin.
    • There is one coat hook.
    • The coat hook is 122cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey, with unshaded light sources.