Summary

Getting Here

Useful Information

Building Parking

  • The building does not have its own dedicated parking.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff, students and visitors within approximately 200m.
    • The name of the car park is Mount Pleasant Car Park.
    • The car park is located in Mount Pleasant.
  • Public Car Parks View
    • There is a car park for public use within 200m (approx).
    • The name of the car park is Liverpool Metropolitan Cathedral Car Park.
    • The car park is located off Mount Pleasant, underneath the Cathedral.
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Car Park (Mount Pleasant)

  • Car Park View
    • The car park is located on Mount Pleasant.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are available.
    • The Blue Badge bay(s) is/are clearly marked.
    • There is/are 5 designated Blue Badge parking bay(s) within this car park.
    • The dimensions of the designated parking bay(s) are 240cm x 450cm.
    • The Blue Badge parking bays have a marked zone to one side and the rear.
    • The marked zone is 130cm wide.
    • The dimensions of the designated bays do not vary in size.
  • Charges and Restrictions View
    • This car park can be used by anybody.
    • Parking charges apply for all except Blue Badge holders.
    • Signs are provided to give information on parking charges/restrictions.
    • Signs are clearly presented.
    • Payment machines are located at the front of the car park.
    • Payment machines are located at the main entrance to the car park/502 Teaching Hub.
    • There is a payment machine at a convenient height for wheelchair users.
    • There is not a level turning space (minimum 185cm x 210cm) in front of the payment machine(s).
    • Payment cannot be made by phone.
    • To see more information on parking policies please click here (opens new tab).
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are clearly signposted from this car park.
    • There is a campus map available within the car park.
    • The nearest designated bay is 35m from the Mount Pleasant.
    • The barriers to enter the car park have a touchscreen you have to press to receive a ticket. This touchscreen is 130cm in height.

Approach (Main Entrance)

  • Approach View
    • The surface of the approach is tarmac and block paving.
    • The approach surface is uneven in places.
    • There is a slope with a very easy incline.
  • Step(s) View
    • The approach shown on the photograph is when approaching to the left of the entrance.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the reception area on the ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'TEACHING HUB 502'.
    • There is step-free access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The height of the key card reader is 120cm.
    • The main door(s) open(s) automatically (towards you).
    • The door(s) is/are double width.
    • The width of the door opening is 168cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are light.
    • The width of the door opening is 172cm.
  • Lift View
    • One leaf of the second set of doors was held open at the time of the survey leaving an opening width of 86cm.

Outside Access (Rear Entrance)

  • Entrance View
    • This information is for the entrance located at the rear of the building.
    • This entrance gives access to the main ground floor corridor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'TEACHING HUB 502'.
    • There is ramped/sloped or stepped access at this entrance.
    • There is not a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does not/do not contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key card is required for access at this entrance.
    • The height of the key card reader is 125cm.
    • The main door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 112cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
    • There is a second set of doors.
    • The door(s) open(s) towards you (pull).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 172cm.
  • Ramp/Slope View
    • The ramp/slope is located to the left as you face the entrance.
    • The gradient of the ramp/slope is steep.
    • The ramp/slope is permanent.
    • There is not a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on both sides of the ramp.
    • The width of the ramp/slope is 130cm (4ft 3in).
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 9 step(s).
    • The step(s) is/are clearly marked.
    • The step(s) has/have tactile paving at the top and bottom.
    • The height of the step(s) is/are between 15cm and 18cm.
    • The height of the step(s) is/are 17cm.
    • The depth of the step(s) is/are not between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides of the step(s).
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
  • Lift View
    • One leaf of the second set of doors was held open at the time of the survey leaving an opening width of 86cm.

Entrance (Ground Floor Link from Guild of Students)

  • Entrance View
    • This information is for the entrance located in the Guild of Students, to the left of the food counter.
    • This entrance gives access to the ground floor via Stair 3.
    • The entrance area/door is not clearly signed.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The height of the key card reader is 100cm.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 172cm.

Entrance (First Floor Link from Guild of Students)

  • Entrance View
    • This information is for the entrance located at the end of a link corridor from the Guild of Students.
    • This entrance gives access to the first floor, next to Stair 3.
    • The entrance area/door is clearly signed.
    • This entrance is signed with '502 Teaching Hub'.
    • There is step-free access at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • The main door(s) open(s) away from you (push).
    • The door(s) is/are double width.
    • The door(s) is/are heavy.
    • The width of the door opening is 156cm.

Reception

  • Reception View
    • The reception point is located immediately beyond the main entrance.
    • The reception point is approximately 6m (6yd 1ft) from the main entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are moderate to good.
    • The height of the reception counter is 111cm .
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 73cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is not a clear knee recess beneath the counter.
    • The counter is staffed.
    • There is not a hearing assistance system at the reception point.
    • There is wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is vinyl.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • The seats do not have armrests.
    • There is sufficient space for a wheelchair user to use the waiting area.

Getting Around

  • Access View
    • There is step-free access throughout the building .
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is carpet and vinyl.
    • Handrails with a rounded or oval profile are not provided in corridors/walkways.
    • There is high colour contrast between the walls and floor in all areas.
    • There are seats without armrests at regular intervals.
    • The lighting levels are varied.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is consistent throughout the building.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is a hearing assistance system in the communal areas of the building.
    • The system is infrared.
    • The lecture theatres and many of the teaching rooms have an Infrared Assistive Hearing System.

Other Floors (Stair 1)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the left of the reception.
    • The stairs are approximately 8m from the main entrance.
    • Signs indicating the location of the stairs are clearly visible from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by stairs are G and 1.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are moderate to good.

Other Floors (Stair 2)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located off the main ground floor corridor.
    • The stairs are approximately 22m from the main entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by stairs are -1, G, 1 and 2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are not between the recommended 15cm and 18cm.
    • The height of the step(s) is/are 19cm.
    • The depth of the step(s) is/are not between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are provided on landings.
    • The lighting levels at the steps are moderate to good.
  • Other Information View
    • Levels -1 and 2 are for staff access only.

Other Floors (Stair 3)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located at the rear of the building.
    • The stairs are approximately 35m from the rear entrance.
    • Signs indicating the location of the stairs are not available from the entrance.
    • There are manual, heavy, double doors to enter and exit the stairwell on all floors.
    • The floors which are accessible by stairs are -1, G and 1.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are not clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on the left going up.
    • Handrails are not at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are low to moderate.
  • Other Information View
    • There is also a handrail on the right going up after the first 4 steps. Level -1 is for staff access only.

Lift (Stair 1)

  • The lift is located in the main stairwell, to the left of the reception.
  • Signs indicating the location of the lift are clearly visible from the entrance.
  • The lift is approximately 16m (17yd 1ft) from the main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are -1, G and 1.
  • The weight limit for the lift is 600.
  • There are manual, heavy, double doors to access the lift lobby on all floors.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do not contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is low.
  • The colour contrast between the external lift control plate and the wall is low.
  • The clear door width is 80cm.
  • The dimensions of the lift are 108cm x 140cm.
  • There are not separate entry and exit doors in the lift.
  • There is not a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are low to moderate.
  • Level -1 is for staff access only.

Lift (Stair 3)

  • The lift is located at the rear of the building, off Stairwell 3.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 40m (43yd 2ft) from the rear entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are -1, G and 1.
  • The weight limit for the lift is 900.
  • There are manual, heavy, double doors to access the lift lobby on all floors.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is low.
  • The colour contrast between the external lift control plate and the wall is low.
  • The clear door width is 90cm.
  • The dimensions of the lift are 128cm x 148cm.
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is a hearing loop system.
  • The lift does have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.
  • Level -1 is for staff access only.

Lecture Theatre(s) (Lecture Theatre 2)

  • Signage for the lecture theatre(s) is available in upper and lower case lettering that is clearly visible on or near the door.
  • The corridor outside the lecture theatre(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
  • There is step free access into the lecture theatre(s) from the corridor.
  • The door opening width(s) is/are 75cm+ for the lecture theatre(s).
  • The door(s) for the lecture theatre(s) is/are not push pad activated.
  • There are designated spaces for wheelchair users within the lecture theatre(s).
  • The designated spaces for wheelchairs users are located at the front.
  • There is level access to the designated seating from an entrance.
  • There is space for an assistance dog.
  • There is step free access to the speaker's area at the front of the lecture theatre(s).
  • The speaker's desk/table is height adjustable.
  • There is staggered seating within the lecture theatre(s).
  • The steps to the staggered seating do not have handrails.
  • There is a hearing assistance system for the lecture theatre(s).
  • The hearing assistance system was not tested at the time of the survey.
  • There is not a visual fire alarm beacon in the lecture theatre(s).
  • There is fixed furniture within the lecture theatre(s).
  • The clear floor space beneath tables in the room(s) is 70cm.
  • A height adjustable table/bench is not available.
  • There are no chairs with armrests on both sides within the lecture theatre(s).
  • The room does have an unobstructed minimum turning space of 150cm x 150cm.
  • Floor coverings in the lecture theatre(s) are even with no trip hazards.
  • There are 3 Lecture Theatres and all located on the first floor. All three have the same layout and features as Lecture Theatre 2 as detailed. Lecture Theatre 3 is slightly smaller (shown in photographs 7 and 8). All the Lecture Theatres have an infrared hearing assistance system.

Toilet with Adaptations (Ground Floor)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located in a corridor to the right hand side of the Reception area.
    • This accessible toilet is approximately 17m (18yd 1ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial, tactile and written text signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 86cm.
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 145cm x 220cm (4ft 9in x 7ft 3in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 80cm (2ft 7in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush, however it is not on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 83cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The contrast between the hand dryer and the wall is low.

Toilet with Adaptations (Ground Floor - Stair 3)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located in a separate cubicle in the male standard toilets in Stairwell 3.
    • This accessible toilet is approximately 28m (30yd 1ft) from the rear entrance.
    • There is step-free access into the accessible toilet.
    • This is a male toilet. There is a separate female accessible toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 90cm.
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is low.
  • Toilet Features View
    • The dimensions of the accessible toilet are 140cm x 182cm (4ft 7in x 5ft 12in).
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are low to moderate.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 78cm (2ft 7in).
    • The transfer space is obstructed by a waste disposal bin.
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is high.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are nappy/incontinence items bin disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet has a backrest.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • The toilet seat colour contrast is high.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 90cm.
    • There is not a towel dispenser.
    • There is not a hand dryer.

Toilet with Adaptations (First Floor)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located in the Social Space on the first floor.
    • This accessible toilet is approximately 27m (29yd 1ft) from the lift.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial, written text and tactile signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 86cm.
    • The contrast between the internal door and wall is high.
    • The door does not have a horizontal grab rail.
  • Toilet Features View
    • The dimensions of the accessible toilet are 153cm x 200cm (5ft x 6ft 7in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are moderate to good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the right.
    • The lateral transfer space is 86cm (2ft 10in).
    • The transfer space is obstructed by a female sanitary bin.
    • There is a flush on the transfer side.
    • There is a spatula type lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is low.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is poor.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary disposal units.
    • There is not a/are not coat hook(s).
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 49cm (1ft 7in).
    • The toilet seat colour contrast is high.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The contrast between the toilet roll holder and the wall is low.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is low.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 85cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The contrast between the hand dryer and the wall is low.

Standard Toilet(s) (Ground Floor - Stair 3)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located in Stairwell 3 at the rear of the ground floor.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 28m from the rear entrance.
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial and written text signage on or near the toilet door.
    • An ambulant toilet cubicle is available.
    • There are horizontal wall mounted rails available on both sides of the toilet.
    • The ambulant toilet does not have vertical wall mounted grab rails.
    • The height of the wash basin(s) is 80cm.
    • The wash basin(s) tap type is lever mixer.
    • Lighting levels are low to moderate.

Standard Toilet(s) (First Floor)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located in the Social Space on the first floor.
    • There is step-free access into the toilet(s).
    • The standard toilet(s) is/are approximately 27m from the lift.
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is tactile and pictorial signage on or near the toilet door.
    • It was not possible to access the female toilet.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 80cm.
    • The wash basin(s) tap type is lever mixer.
    • Lighting levels are moderate to good.