Skip to main content
The new name for DisabledGo

Dental School

The University of Liverpool, Pembroke Place, Liverpool, L3 5PS

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Building View
    • Services / Facilities within the building include; The School of Dentistry, lecture theatres, laboratory, meeting rooms, computer suite and adjoining hospital teaching areas.
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located to the right as you enter.
    • Female standard toilet facilities are located off the stairway landing, between the ground and basement levels, to the right as you enter the rear entrance to the basement level, to the left as you enter the rear entrance to the basement level, within the standard changing rooms.
    • Male standard toilet facilities are located off the stairway landing, between the ground and mezzanine levels, to the left as you enter the rear entrance to the basement level, to the left as you enter the rear entrance to the basement level, within the standard changing rooms.
    • Standard changing facilities are located to the left as you enter the rear entrance to the basement level.
    • Standard shower facilities are located to the left as you enter the rear entrance to the basement level, within the standard changing rooms.
    • There are further toilet facilities within the adjoining hospital building.

Getting Here

Useful Information

Building Parking (Hospital Staff Car Park)

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by staff and Blue Badge holders.
    • There are no parking charges that apply on the day.
    • The car park is located to the rear of the building.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 4 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) is/are clearly marked.
    • The dimensions of the designated parking bay(s) are 230cm x 480cm.
    • The Blue Badge parking bays have a marked zone to both sides and rear.
    • The marked zone is 130cm wide.
    • The dimensions of the designated bays do not vary in size.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 18m from the rear entrance.
    • The route from the car park to the building is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are slopes/ramps.
    • The car park surface is tarmac.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff, students and visitors within approximately 200m.
    • The name of the car park is Elizabeth Street Staff Car Park No.20.
    • The car park is located off Pembroke Place.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • On Street Parking View
    • Clearly signed and/or standard marked parking bays are not available.
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Car Park (Elizabeth Street Staff Car Park No.20)

  • Car Park View
    • The car park is located off Pembroke Place, designated as Car Park 20 on the University Campus Map.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is tarmac.
    • Designated Blue Badge parking bays are available.
    • The Blue Badge bay(s) is/are clearly marked.
    • There is/are 4 designated Blue Badge parking bay(s) within this car park.
    • The dimensions of the designated parking bay(s) are 235cm x 490cm.
    • The Blue Badge parking bays have a marked zone to both sides and rear.
    • The marked zone is 130cm wide.
    • The dimensions of the designated bays do not vary in size.
  • Charges and Restrictions View
    • This car park can be used by staff and Blue Badge holders.
    • There are no parking charges that apply on the day.
    • Signs are provided to give information on parking charges/restrictions.
    • Signs are clearly presented.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are clearly signposted from this car park.
    • There is not a campus map available within the car park.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the ground floor.
    • The entrance area/door is clearly signed.
    • This entrance is signed with 'Dental School'.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • A key fob is required for access at this entrance.
    • The height of the key fob reader is 100cm.
    • The main door(s) open(s) automatically.
    • The exit push pad or push button is 113cm from floor level.
    • The door(s) is/are double width.
    • The width of the door opening is 145cm.
    • There is a second set of doors.
    • The door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 129cm.
  • Ramp/Slope View
    • The ramp/slope is located to the right as you face the entrance.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on the left going up the ramp.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 4 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are not between 15cm and 18cm.
    • The height of the step(s) is/are 19cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides of the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.

Outside Access (Rear Entrance)

  • Entrance View
    • This information is for the entrance located at the rear of the building.
    • This entrance gives access to the basement level and hospital lifts.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is an intercom.
    • The height of the intercom is 88cm .
    • A key fob is required for access at this entrance.
    • The main door(s) open(s) automatically (towards you).
    • The exit push pad or push button is 99cm from floor level.
    • The door(s) is/are double width but one door is locked.
    • The width of the door opening is 75cm.
    • There is a second set of doors.
    • The door(s) open(s) automatically (towards you).
    • The door(s) is/are double width.
    • The width of the door opening is 132cm.
  • Ramp/Slope View
    • The ramp/slope is located leading down to the entrance.
    • The gradient of the ramp/slope is slight.
    • There is a level landing at the top of the ramp/slope.

Outside Access (Hospital Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the hospital building to the left.
    • This entrance gives access to the ground floor.
    • The entrance area/door is not clearly signed.
    • This entrance is signed with 'Liverpool University Dental Hospital'.
    • There is ramped/sloped or stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 145cm.
    • There is a second set of doors.
    • The door(s) open(s) automatically.
    • The door(s) is/are double width.
    • The width of the door opening is 149cm.
  • Ramp/Slope View
    • The ramp/slope is located to the right as you face the entrance.
    • The gradient of the ramp/slope is slight.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on both sides of the ramp.
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located in front of the entrance.
    • There is/are 9 step(s).
    • The step(s) is/are clearly marked.
    • The step(s) has/have tactile paving at the top and bottom.
    • The height of the step(s) is/are not between 15cm and 18cm.
    • The height of the step(s) is/are 21cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides of the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a second lower handrail.

Entrance (Hospital Link)

  • Entrance View
    • This information is for the entrance located ahead as you enter, beyond reception leading to the hospital.
    • There is step free access at this entrance.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The height of the card reader/lock is 115cm (3ft 9in).
    • The main door(s) open(s) towards you (pull).
    • The door(s) is / are single (with an unlocked extension leaf).
    • The door(s) may be difficult to open.
    • The width of the door opening is 127cm (4ft 2in).
  • Second Set of Doors View
    • There is a second set of doors.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is / are double.
    • The door(s) may be difficult to open.
    • The width of the door opening is 129cm (4ft 3in).

Reception

  • Reception View
    • The reception point is located to the left as you enter.
    • The reception point is approximately 11m (12yd 1in) from the main entrance.
    • The reception area/desk is clearly visible from the entrance.
    • There is step-free access to the reception point.
    • There is a clear unobstructed route to the reception point.
    • There are no windows, TVs, glazed screens or mirrors at/behind the reception point which could adversely affect the ability of someone to lip read.
    • The reception counter is not placed in front of a background which is patterned.
    • The lighting levels at the reception point are good.
    • The height of the reception counter is 114cm .
    • There is sufficient space to write or sign documents on the counter.
    • There is a lowered section of the counter.
    • The height of the lowered section at the counter is 73cm.
    • There is sufficient space to write or sign documents on the lowered section of the counter.
    • There is a clear knee recess beneath the counter.
    • The counter is not staffed.
    • There is not a bell to attract attention.
    • Clipboards can be provided to anyone who is unable to use the desk.
    • There is not a hearing assistance system at the reception point.
    • There is wayfinding signage available at/close to the reception.
    • The type of flooring in the reception area is tiles.
  • Reception Waiting Area View
    • There is a waiting area close to the reception point.
    • Access to the waiting area is unobstructed.
    • There is armchair seating in the waiting area.
    • There is sufficient space for a wheelchair user to use the waiting area.

Getting Around

  • Access View
    • There is step-free access throughout the majority of the building.
    • The basement level, although this can be overcome by using the separate entrances.
  • Circulation View
    • There are doors in corridors/walkways which have to be opened manually.
    • The type of flooring in corridors/walkways is laminate and tiles.
    • There are no seats/chairs at regular intervals.
    • The lighting levels are good.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is not consistent throughout the building.
    • Dementia friendly signage is not provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • This venue does not play background music in communal areas.
    • There is a hearing assistance system in the communal areas of the building.
    • The system is a fixed loop.
    • The hearing loop is fitted in the first floor multi-skills laboratory.
    • Staff are not trained to use the hearing system.

Lecture Theatre(s) (Lower Lecture Theatre)

  • Directional and locational signage for the lecture theatre(s) is available in upper and lower case lettering that is clearly visible.
  • The corridor outside the lecture theatre(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
  • There is step free access into the lecture theatre(s).
  • The door opening width(s) is/are 75cm+ for the lecture theatre(s).
  • The door(s) for the lecture theatre(s) is/are not push pad activated.
  • There are designated spaces for wheelchair users within the lecture theatre(s).
  • The designated spaces for wheelchairs users are located at the back.
  • There is level access to the designated seating from an entrance.
  • There is space for an assistance dog.
  • There is not step free access to the speaker's area at the front of the lecture theatre(s).
  • There are 7 deep steps down and 1 medium step up to the speaker's area.
  • The height of the speaker's desk/table is 91cm.
  • The speaker's desk/table is not height adjustable.
  • There is (staggered) tiered seating within the lecture theatre(s).
  • The steps to the (staggered) tiered seating do not have handrails.
  • There is not a hearing assistance system for the lecture theatre(s).
  • There is a visual fire alarm beacon in the lecture theatre(s).
  • There is fixed furniture within the lecture theatre(s).
  • The clear floor space beneath tables in the room(s) is 71cm.
  • A height adjustable table/bench is not available.
  • There is a/are chair(s) with armrests on both sides within the lecture theatre(s).
  • The room does not have an unobstructed minimum turning space of 150cm x 150cm.
  • Floor coverings in the lecture theatre(s) are even with no trip hazards.

Lecture Theatre(s) (Upper Lecture Theatre)

  • Directional and locational signage for the lecture theatre(s) is available in upper and lower case lettering that is clearly visible.
  • The corridor outside the lecture theatre(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
  • There is step free access into the lecture theatre(s).
  • The door opening width(s) is/are 75cm+ for the lecture theatre(s).
  • The door(s) for the lecture theatre(s) is/are not push pad activated.
  • There are designated spaces for wheelchair users within the lecture theatre(s).
  • The designated spaces for wheelchairs users are located at the back.
  • There is level access to the designated seating from an entrance.
  • There is space for an assistance dog.
  • There is not step free access to the speaker's area at the front of the lecture theatre(s).
  • There are 9 deep steps down to and 1 up to the speaker's area.
  • The height of the speaker's desk/table is 91cm.
  • The speaker's desk/table is not height adjustable.
  • There is (staggered) tiered seating within the lecture theatre(s).
  • The steps to the (staggered) tiered seating do not have handrails.
  • There is not a hearing assistance system for the lecture theatre(s).
  • There is a visual fire alarm beacon in the lecture theatre(s).
  • There is fixed furniture within the lecture theatre(s).
  • The clear floor space beneath tables in the room(s) is 71cm.
  • A height adjustable table/bench is not available.
  • There are no chairs with armrests on both sides within the lecture theatre(s).
  • The room does have an unobstructed minimum turning space of 150cm x 150cm.
  • Floor coverings in the lecture theatre(s) are even with no trip hazards.

Other Floors

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the right as you enter.
    • The stairs are approximately 9m from the main entrance.
    • The stairs are clearly visible from the entrance.
    • The floors which are accessible by stairs are B, G and 1.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are low to moderate.
  • Other Information View
    • The service(s) on the floors which are not accessible is/are the female and male toilets, and the mezzanine level computer suite (shown in photographs 3 and 4).

Lift

  • The lift is for staff use only.
  • The lift is located to the right as you enter.
  • Signs indicating the location of the lift are clearly visible from the entrance.
  • The lift is approximately 20m (21yd 2ft) from the main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are G and 1.
  • The weight limit for the lift is 800kg.
  • Clear signs indicating the facilities on each floor are provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is medium.
  • The colour contrast between the external lift control plate and the wall is low.
  • The clear door width is 89cm.
  • The dimensions of the lift are 127cm x 132cm.
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are moderate to good.

Other Floors (Hospital)

  • Stairs View
    • Stairs can be used to access other floors.
    • The stairs are located to the left as you enter, adjacent to the lifts.
    • The stairs are approximately 15m from the hospital entrance.
    • The stairs are clearly visible from the entrance.
    • The floors which are accessible by stairs are G,2.
    • There are 15+ steps between floors.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between the recommended 30cm and 45cm.
    • The steps are clearly marked.
    • There is a/are handrail(s) at the step(s).
    • The steps have a handrail on both sides.
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are not easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.
    • There is a landing.
    • Clear signs indicating the facilities on each floor are not provided on landings.
    • The lighting levels at the steps are good.

Lift (Hospital)

  • The lift is for staff use only.
  • The lift is located to the right as you enter.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 45m (49yd 8in) from the rear entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are B, G, 2.
  • The weight limit for the lift is 1600 Kg.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is high.
  • The colour contrast between the external lift control plate and the wall is high.
  • The clear door width is 120cm.
  • The dimensions of the lift are 127cm x 214cm.
  • There are not separate entry and exit doors in the lift.
  • There is not a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is a hearing loop system.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are good.
  • There is a/are similar lift(s) available.
  • These lifts are located to the left if you enter the hospital entrance.

Accessible Toilet(s)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located to the right as you enter.
    • This accessible toilet is approximately 15m (16yd 1ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial signage on or near the toilet door.
    • The contrast between the external door and wall is medium.
    • The door opens outwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the accessible toilet opening is 96cm.
    • The contrast between the internal door and wall is medium.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 200cm x 200cm.
    • The accessible toilet does not have an unobstructed minimum turning space of 150cm x 150cm.
    • The height of the light switch/pull cord is 76cm from floor level.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 146cm.
    • The transfer space is obstructed by a waste disposal bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a lever flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is high.
    • The contrast between the walls and floor is medium.
    • There is an emergency alarm.
    • The emergency pull cord alarm was out of reach (higher than 10cm (4") from floor) when surveyed.
    • There is not a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and pedal bin disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 160cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is not placed at a lower level or at an angle for ease of use.
    • The toilet has a cistern.
    • The height of the toilet seat above floor level is 48cm (1ft 7in).
    • The toilet seat colour contrast is high.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 87cm (2ft 10in).
    • The contrast between the toilet roll holder and the wall is medium.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 80cm (2ft 7in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 123cm.
    • There is not a towel dispenser.
    • There is a hand dryer.
    • The hand dryer is placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 112cm (3ft 8in).
    • The contrast between the hand dryer and the wall is medium.

Standard Toilet(s)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The male toilet is located off the landing between the ground and mezzanine levels.
    • There is stepped access into the toilet(s).
    • The colour contrast between the external toilet door(s) and wall(s) is medium.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 82cm.
    • The wash basin(s) tap type is twist/turn.
    • Lighting levels are moderate to good.
    • There are 7 steps down up the male toilets from the ground floor (shown in photograph 3).
  • Toilet Facilities 2 View
    • The female toilet is located off the landing between the ground and basement levels.
    • There is stepped access into the toilet(s).
    • The colour contrast between the external toilet door(s) and wall(s) is medium.
    • There is pictorial signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • There are 9 steps down to the female toilets from the ground floor (shown in photograph 4).
  • Baby Changing Facilities 2 View
    • There are additional male and female toilets on the basement, near the rear entrance (shown in photographs 5 and 6) and within the standard changing rooms.

Standard Changing Room (Basement)

  • Location and Access View
    • This standard changing room is located on the basement level, to the left as you enter.
    • This standard changing room is approximately 56m from the rear entrance.
    • A key is not required for the standard changing room.
    • There is pictorial signage on or near the standard changing room door.
    • The contrast between the external door and wall is medium.
    • The door opens inwards.
    • The door is heavy.
    • The door is locked by a lever twist.
    • The width of the standard changing room opening is 79cm.
    • The contrast between the internal door and wall is medium.
    • The door does not have a horizontal grab rail.
  • Changing Facilities View
    • The dimensions of the standard changing room are 900cm x 750cm.
    • The fixtures/facilities available in the standard changing room include; a wash basin, a changing table/bench and a toilet.
    • Other fixtures/facilities available include; standard showers.
    • This is a male changing room.
    • The type of flooring in the changing room is laminate.
    • There is not a red flashing fire alarm beacon within the standard changing room.
    • There is not an emergency alarm.
    • There is seating available within the changing room.
    • The seating within the changing room includes: bench seating.
    • There are lockers within the changing room.
    • There is a/are locker(s) within reach for a wheelchair user.
    • There is not a water dispenser available.
    • There is a/are coat hook(s).
    • The height of the coat hook is 160cm from the floor.
    • Disposal facilities are available in the changing room.
    • There is a/are general waste (with lid) disposal units.
    • The lighting levels in the changing room are good.
  • Comments View
    • There are female changing facilities opposite.

Standard Shower (Basement)

  • Shower facilities are available.
  • The shower(s) surveyed is/are located within the standard changing rooms.
  • There is level access to the shower facilities.