Skip to main content
The new name for DisabledGo

Riverside Sports Complex - Pavilion A

University of Nottingham, Lenton Lane , Nottingham , NG7 2SA

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

  • Building View
    • Services / Facilities within the building include; changing areas, tea rooms, accessible and standard toilets.
    • Services / Facilities within the grounds include; rugby and football pitches.
  • Location of Toilet/Changing Facilities View
    • Accessible toilet facilities are located off the main corridor.
    • Female standard toilet facilities are located within the standard changing areas.
    • Baby changing facilities are located withing the accessible toilet.
    • Standard changing facilities are located off the main corridor.
    • Standard shower facilities are located within the standard changing areas.

Getting Here

  • By Road View
    • The Riverside Sports Complex is located on the south side of the city. From the M1 leave at Junction 24 and take the A453 towards the city centre. At the Queens Drive roundabout take the first exit and then the first left on to Lenton Drive.
    • A large area of undesignated parking is located at the rear of Pavilion A. A small area of parking with Blue Badge bays are located adjacent to both Pavilions. Pavilion B has a standard drop of point and coach drop off point.
  • By Bus View
    • There is not a bus stop within 150 metres of the campus.
  • By Train View

Useful Information

Building Parking (Pavilion A)

  • The building does have its own dedicated parking.
  • Building Car Park View
    • The car park can be used by staff, students and visitors.
    • There are no parking charges that apply on the day.
    • The car park is located off the access road opposite Pavilion A.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • Designated Blue Badge parking bays are available.
    • There is/are 2 designated parking bay(s) within the car park.
    • The Blue Badge bay(s) markings are faded.
    • The dimensions of the designated parking bay(s) are 232cm x 466cm.
    • The Blue Badge parking bays have a marked zone to one side and the rear.
    • The marked zone is 130cm wide.
    • The dimensions of the designated bays do not vary in size.
    • Parking spaces for Blue Badge holders do not need to be booked in advance.
    • The nearest designated bay is 103m (112yd 1ft) from the main entrance.
    • The route from the car park to the building is accessible to a wheelchair user with assistance.
    • Assistance may be required because there is / are dropped kerbs.
    • The dropped kerb between the car park and the building does have tactile paving.
    • The car park surface is tarmac.
  • Site/Campus Car Parks View
    • There is a site/campus car park for staff, students and visitors within approximately 200m.
    • The name of the car park is Riverside Sports Complex.
    • The car park is located to the right as you enter the site.
  • Public Car Parks View
    • There is not a car park for public use within 200m (approx).
  • On Street Parking View
    • Clearly signed and/or standard marked parking bays are not available.
  • Drop Off Point View
    • There is not a designated drop off point.

Site/Campus Car Park (Riverside Sports Complex)

  • Car Park View
    • The car park is located to the right from the access road.
    • The nearest building(s) to this car park is/are Pavilion A.
    • The car park type is open air/surface.
    • The car park does not have a height restriction barrier.
    • The car park surface is loose chippings.
    • Designated Blue Badge parking bays are not available.
  • Charges and Restrictions View
    • This car park can be used by staff, students and visitors.
    • There are no parking charges that apply on the day.
    • Signs are not provided to give information on parking charges/restrictions.
  • Drop Off Point View
    • There is not a designated drop off point in this car park.
  • Car Park Access View
    • There is step free access from this car park.
    • Buildings are not clearly signposted from this car park.
    • There is not a campus map available within the car park.

Outside Access (Main Entrance)

  • Entrance View
    • This information is for the entrance located at the front of the building.
    • This entrance gives access to the main corridor.
    • The entrance area/door is not clearly signed.
    • There is ramped/sloped and stepped access at this entrance.
    • There is a canopy or recess which provides weather protection at this entrance.
    • The entrance door(s) does/do contrast visually with its immediate surroundings.
    • There is not a bell/buzzer.
    • There is not an intercom.
    • The main door(s) open(s) towards you (pull).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 94cm.
    • There is a small lip on the threshold of the entrance, with a height of 2cm or below.
  • Ramp/Slope View
    • The ramp/slope is located to the right of the entrance as you face it and to the left of the entrance after the steps.
    • The gradient of the ramp/slope is slight.
    • The ramp/slope is permanent.
    • There is a level landing at the top of the ramp/slope.
    • There is a/are handrail(s) at the ramp.
    • The handrail(s) is/are on both sides of the ramp.
    • The width of the ramp/slope is 136cm (4ft 6in).
    • The ramp/slope does bypass the step(s).
  • Step(s) View
    • The step(s) is/are located to the left of the entrance as you face it.
    • There is/are 8 step(s).
    • The step(s) is/are not clearly marked.
    • The step(s) has/have tactile paving at the top and bottom.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is a/are handrail(s) at the step(s).
    • The handrail(s) is/are on both sides of the step(s).
    • Handrails are at the recommended height (90cm-100cm).
    • Handrails do cover the flight of stairs throughout its length.
    • Handrails are easy to grip.
    • Handrails do not extend horizontally beyond the first and last steps.

Inside Access

  • Access and Circulation View
    • There is step-free access throughout the building.
    • The type of flooring is vinyl.
    • There is some flooring which is shiny and could cause issues with glare or look slippery to some people.
    • There is a medium colour contrast between the walls and floor.
    • The lighting levels are good.
  • Signage View
    • Wayfinding signage is provided.
    • The colour, design and typeface of signs is consistent throughout.
    • Dementia friendly signage is provided.
  • Safe Place(s) View
    • There is not a designated place of safety which can be used by people with dementia, autism or learning disabilities.
  • Audio View
    • There is not a hearing assistance system.

Kitchen/Dining Area (Tea Room)

  • The kitchen/dining area is accessed by a single door with an opening width of over 75cm.
  • Lowered work surfaces are not available.
  • The kitchen does not have an unobstructed floor space of at least 150cm × 150cm.
  • There is a knee recess under a work surface.
  • A knee recess is provided adjacent to the refrigerator.
  • Knee recesses are at least 80cm wide.
  • There are some low level cupboards.
  • There are easy to grip handles or taps for cupboards, the refrigerator and the sink.
  • The height of the dining table is 66cm.
  • There are dining chairs with and without armrests.
  • Access to kitchen area is via a gap 58cm wide.

Changing Area

  • Changing Area View
    • There is a/are changing area(s) available.
    • The changing area that was surveyed is located ahead as you enter the building, right at the end of the corridor then along the corrido and on the left.
    • The changing area is approximately 15m from the main entrance.
    • There is step-free access to the changing area.
    • The facilities available within the changing area include; standard showers and standard toilets.
    • This changing area is interchangeable between male and female.
    • Similar shared changing area(s) are available.
    • The door(s) open(s) away from you (push).
    • The door(s) is/are single width.
    • The door(s) is/are heavy.
    • The width of the door opening is 87cm.
    • The type of flooring in the changing area is vinyl.
    • There is a flashing fire alarm beacon within the changing area.
    • There are changing benches or seats within the changing area.
    • There are no lockers within the changing area.
    • There is not a water dispenser available.
    • The lighting levels in the changing area are good.
  • Shower Facilities View
    • Shower facilities are available.
    • There is step-free access to the shower facilities.
    • The shower head height(s) is/are fixed.
    • The shower control type(s) is/are push.
    • There is no seat for the shower(s).
    • There is not a/are not wall-mounted grab rail(s) available for the shower(s).
  • Toilet Facilities View
    • Toilet facilities are available.
    • There is step-free access to the toilet(s).
    • An ambulant toilet with wall-mounted grab rails is not available.
    • The wash basin(s) tap type is push.
    • The lighting levels in the toilet(s) are good.
  • Baby Changing Facilities View
    • Access to the standard showers is via a 90cm opening. There is 150cm x 150cm manoeuvring within the standard shower. Shower button control is 110cm high. The sink in the standard toilet is 80cm high. There are 19 changing room and two for umpires and officials. Rugby and American football changing rooms are designated for changing rooms 16, 17 18 and 19. There is a water dispenser adjacent to changing room 12. The sink is 80cm high and the tap 110cm high.

Accessible Toilet(s) (Right Hand Transfer)

  • There is an/are accessible toilet(s) available.
  • Location and Access View
    • This accessible toilet is located ahead as you enter the building, right at the end of the corridor then along the corridor and to the right.
    • This accessible toilet is approximately 15m (16yd 1ft) from the main entrance.
    • There is step-free access into the accessible toilet.
    • This is a shared toilet.
    • A key is not required for the accessible toilet.
    • There is pictorial and written text signage on or near the toilet door.
    • The contrast between the external door and wall is high.
    • The door opens outwards.
    • The door is light.
    • The door is locked by a twist lock.
    • The width of the accessible toilet opening is 87cm.
    • The contrast between the internal door and wall is high.
    • The door has a horizontal grab rail.
    • The contrast between the horizontal grab rail and internal door is high.
  • Toilet Features View
    • The dimensions of the accessible toilet are 396cm x 230cm (12ft 12in x 7ft 7in).
    • The accessible toilet does have an unobstructed minimum turning space of 150cm x 150cm.
    • The lighting levels are good.
    • There is a lateral transfer space.
    • As you face the toilet pan the transfer space is on the left.
    • The lateral transfer space is 167cm (5ft 6in).
    • The transfer space is obstructed by a female sanitary bin and a waste disposal bin.
    • There is a flush on the transfer side.
    • There is not a spatula type lever flush.
    • There is a push button flush.
    • There is a dropdown rail on the transfer side.
    • The contrast between the dropdown rail(s) and wall is high.
    • There is a/are wall-mounted grab rail(s) available.
    • As you face the toilet the wall-mounted grab rail(s) is/are on both sides.
    • There is a vertical wall-mounted grab rail on the transfer side.
    • There is a horizontal wall-mounted grab rail on the opposite side of the seat to the transfer space.
    • The contrast between the wall-mounted grab rail(s) and wall is high.
    • The contrast between the walls and floor is high.
    • There is an emergency alarm.
    • The emergency pull cord alarm is fully functional.
    • There is a red flashing fire alarm beacon within the toilet.
    • Disposal facilities are available in the toilet.
    • There is a/are female sanitary and general waste (with lid) disposal units.
    • There is a/are coat hook(s).
    • The height of the coat hook is 140cm from the floor.
  • Additional Fixtures View
    • There is a mirror.
    • The mirror is placed at a lower level or at an angle for ease of use.
    • There is not a shelf within the accessible toilet.
    • The toilet has a cistern.
    • There is a lid attached to the toilet seat.
    • The height of the toilet seat above floor level is 47cm (1ft 7in).
    • The toilet seat colour contrast is low.
    • There is a toilet roll holder.
    • The toilet roll holder can be reached from seated on the toilet.
    • The toilet roll holder is not placed higher than 100cm (3ft 3in).
    • The height of the toilet roll holder is 97cm (3ft 2in).
    • The contrast between the toilet roll holder and the wall is high.
    • There is a wash basin.
    • The wash basin and tap(s) can be reached from seated on the toilet.
    • The wash basin is not placed higher than 74cm (2ft 5in).
    • The height of the wash basin is 72cm (2ft 4in).
    • There are vertical wall-mounted grab rails on both sides of the wash basin.
    • The contrast between the wash basin wall-mounted grab rail(s) and wall is high.
    • The wash basin tap type is lever mixer.
    • There is a wall fixed soap dispenser.
    • The soap dispenser cannot be reached from seated on the toilet.
    • The height of the soap dispenser is 90cm.
    • There is a towel dispenser.
    • The towel dispenser can be reached from seated on the toilet.
    • The towel dispenser is not placed higher than 100cm (3ft 3in).
    • The height of the towel dispenser is 100cm (3ft 3in).
    • The contrast between the towel dispenser and the wall is high.
    • There is a hand dryer.
    • The hand dryer is not placed higher than 100cm (3ft 3in).
    • The height of the hand dryer is 80cm (2ft 7in).
    • The contrast between the hand dryer and the wall is low.
  • Baby Changing Facilities View
    • Baby changing facilities are located within the accessible toilet.
    • There is a flip down baby change table available .
    • The height of the baby change table is 93cm.

Step(s) (External Standard Toilets)

  • Stepped Level Change 1 View
    • There is a/are step(s) located at the threshold of the External Standard Toilets.
    • The step(s) is/are used to access the External Standard Toilets.
    • There is/are 1 step(s).
    • The step(s) is/are not clearly marked.
    • The height of the step(s) is/are between the recommended 15cm and 18cm.
    • The depth of the step(s) is/are between 30cm and 45cm.
    • There is not a/are not handrail(s) at the step(s).

Standard Toilet(s) (External Standard Toilets)

  • Standard toilet facilities are available.
  • Toilet Facilities View
    • The female and male toilets are located on the end of the building to the left of the main entrance as you face it.
    • There is step-free access into the toilet(s).
    • The colour contrast between the external toilet door(s) and wall(s) is high.
    • There is pictorial and written text signage on or near the toilet door.
    • An ambulant toilet cubicle is not available.
    • The height of the wash basin(s) is 78cm.
    • The wash basin(s) tap type is push.
    • Lighting levels are good.