Access Guide
Location of Room(s)
- G.06 - G.07 is located on the ground floor of the Lady Hale Building, to the left from the main entrance
- There is step free access from the Lady Hale Building main entrance to G.06 - G.07.
- To view the AccessAble Access Guide for Lady Hale Building please click here (new tab).
Teaching/Seminar Room(s) (G.06 - G.07)
- Signage for the room(s) is available in upper and lower case lettering that is clearly visible on or near the door.
- The corridor outside the room(s) is sufficiently wide enough (150cm+) to allow wheelchair users to pass.
- There is step free access into the room(s) from the corridor.
- The door opening width(s) is/are 75cm+ for the room(s).
- The door(s) for the room(s) is/are not push pad activated.
- There is step free access to the speaker's area at the front.
- The height of the lectern is 90cm.
- The lectern is not height adjustable.
- There is not a hearing assistance system for the room(s).
- There is a visual fire alarm beacon in the room(s).
- There is some fixed furniture within the room(s).
- The clear floor space beneath tables in the room(s) ranges between 67cm and 70cm.
- A height adjustable table/bench is not available.
- There is a/are chair(s) with armrests on both sides within the room(s).
- The room does have an unobstructed minimum turning space of 150cm x 150cm.
- Floor coverings in the room(s) are even with no trip hazards.
- There is a platform at the left side of the room, which is accessed by a ramp/step.
There are armchairs and a desk on the platform.
-
Comments
View
- Rooms 06 and 07 can be configures as two separate rooms or one large room, subject to use of the room divider.
Ramp(s) / Slope(s) and Step(s) (Platform)
-
Ramp / Slope
View
- There is a ramp/slope located at the left end of the Room G.06 - G.07.
- The ramp/slope is used to access a low platform.
- The gradient of the ramp/slope is steep.
- The ramp/slope is permanent.
- There is not a level landing at the top of the ramp/slope.
- There is not a/are not handrail(s) at the ramp.
- The lighting levels at the ramp/slope are good.
- The ramp/slope does bypass the step(s).
-
Step(s)
View
- There is a/are step(s) located to the right of the ramp.
- The step(s) is/are used to access a low platform.
- There is/are 1 step(s).
- The step(s) is/are clearly marked.
- The height of the step(s) is/are not between the recommended 15cm and 18cm.
- The height of the step(s) is/are 13cm.
- The depth of the step(s) is/are between the recommended 30cm and 45cm.
- There is not a/are not handrail(s) at the step(s).
- The lighting levels at the step(s) are good.