Skip to main content

Community Room - M1 - Leeds Skelton Lake Services - EXTRA

M1 - Leeds Skelton Lake Services - EXTRA, M1 Junction 45, Leeds, West Yorkshire, LS9 0AS

View Accessibility Symbols

Accessibility Symbols

For more information about what these symbols mean, view our Accessibility Symbols Guide.

Close this popup window.

Access Guide

Show Easy Read

Summary

Stairs (Viewing Deck)

  • The stairs are located at the rear of the services building.
  • The floors which are accessible by stairs are G, 1, 2.
  • There are 25 steps between floors.
  • The height of the steps are between the recommended 15cm and 18cm.
  • The depth of the steps are between the recommended 30cm and 45cm.
  • The steps are not clearly marked.
  • There is a/are handrail(s) at the steps.
  • The steps have a handrail on both sides.
  • Handrails are at the recommended height (90cm-100cm).
  • Handrails do cover the flight of stairs throughout its length.
  • Handrails are easy to grip.
  • Handrails do not extend horizontally beyond the first and last steps.
  • There is a landing.
  • Clear signs indicating the facilities/services are not provided on landings.
  • The lighting levels at the steps are moderate to good.

Lift

  • The lift is located at the rear right of the services building.
  • Signs indicating the location of the lift are not available from the entrance.
  • The lift is approximately 49m from the main entrance.
  • The lift is a standard lift.
  • A member of staff does not need to be notified for use of the lift.
  • The floors which are accessible by this lift are G, 1 and 2.
  • Clear signs indicating the facilities on each floor are not provided on lift lobby landings.
  • There is a clear level manoeuvring space of 150cm × 150cm in front of the lift.
  • Lift doors do contrast visually with lift lobby walls.
  • The external controls for the lift are within 90cm - 110cm from the floor.
  • The colour contrast between the external lift controls and the control plate is good.
  • The colour contrast between the external lift control plate and the wall is good.
  • The width of the door opening is 90cm.
  • The dimensions of the lift are 120cm x 192cm.
  • There are not separate entry and exit doors in the lift.
  • There is a mirror to aid reversing out of the lift.
  • There is not a list of floor services available within the lift.
  • The lift does have a visual floor indicator.
  • The lift does have an audible announcer.
  • The internal controls for the lift are within 90cm - 120cm from the floor.
  • There is not a hearing assistance emergency alarm system in the lift.
  • The lift does not have Braille markings.
  • The lift does have tactile markings.
  • The lighting levels in the lift are low to moderate.
  • The viewing area on the second floor can only be accessed between the hours of 07:00 - 19:00.

Conference / Meeting Room(s) (First Floor)

  • The room surveyed was the Community Room.
  • The Community Room is located on the first floor, to the left of the staircase.
  • There is not wayfinding signage for the room.
  • There is clear signage for the room (on or near the door).
  • There is written signage for the room, in upper and lower case lettering, that is clearly visible.
  • Staff can provide assistance getting to the room.
  • The corridor/walkway leading to the room is sufficiently wide enough (120cm+).
  • There is step-free access into the room.
  • The door(s) open(s) towards you (pull).
  • The door(s) is/are double width.
  • The door(s) may be difficult to open.
  • The width of the door opening is 170cm.
  • The contrast between the external door(s) and wall(s) is good.
  • The contrast between the internal door(s) and wall(s) is good.
  • There is not a hearing assistance system available for the room.
  • There is not fixed furniture within the room.
  • The distance between the floor and the underside of the table is 85cm.
  • The room has an unobstructed minimum turning space of 150cm x 150cm.
  • A height adjustable desk is not available.
  • There are some chairs with armrests on both side within the room.
  • Room Details View
    • There are no potential trip hazards within the room.
    • There is flooring which is shiny and could cause issues with glare or look slippery to some people.
    • The contrast between the walls and floor is good.
    • The lighting levels are good.
    • The lighting is activated by a sensor.
    • The height of the light switch/pull cord is 135cm from floor level.
    • A card reader at a height of 116cm is used to access the room.
      There is a push button to exit the room at a height of 120cm.