Show Easy Read

Evacuation and Fire Safety Provisions

Overview

Rooms and Services in the Building

Toilet and Changing Facilities

  • Toilet Facilities View
    • There are 8 toilets with adaptations.
    • Toilets with adaptations are located on the ground, first, second, third, fourth, fifth, sixth and eighth floors.
    • The transfer space varies between left and right in the toilets with adaptations.
    • Ambulant toilet facilities are located on the sixth floor.
    • The male and female step-free toilet facilities are located on the first, second, third, fourth, fifth, seventh and eight floors.
    • The shared step-free toilet facilities are located on the sixth floor.
    • The female step-free toilet facilities are located on the sixth floor.
  • Washroom and Shower Facilities View
    • Standard shower facilities are located within the toilet with adaptation on the ground floor and on the sixth floor.

Getting Inside

  • The approach to the building is step-free via an easy slope.
  • Malet Place Engineering Building has one external entrance and nine internal entrances from the Roberts Building and Darwin Extension.
    The external entrance provides step-free level access to the ground floor.
    The doors are double and automatic.
  • The main entrance is signed as UCL Engineering - Malet Place Engineering Building.
  • The main entrance provides step-free level access to the ground floor.
  • The internal entrances are as follows:
    Floor -2
    There are two sets of double manual doors from the Roberts Building and Darwin Extension with level access.

    Floor 1
    There are two sets of single automatic doors from the Roberts Building and Darwin Extension via the link bridge.
    There is a slight ramp with handrails on both sides beyond the second door.

    Floors 2 to 7 There are two sets of single manual doors from the Roberts Building and Darwin Extension via the link bridge with level access.

Getting Around

  • There is step-free level access throughout the building on all floors.
  • On the ground floor there is slight ramp to access the alternative lift and main stairs.
    There are also 6 steps from the alternative lift lobby to access the main staircase.
    There is tactile paving at the top and bottom of the steps.
  • There are two sets of 6 steps along the first floor corridor. Alternatively there is a stair lift to overcome the steps.
  • Floor surfaces along all circulation routes are carpeted.
    There are also hard and smooth surfaces with some having a shiny finish.
  • There is seating available in some lobby areas with a mixture of seating.
  • Wall mounted wayfinding signage is provided throughout the building.
  • There are manual doors along circulation routes throughout the building.

Entrance (Main Entrance)

  • This entrance is located at the front of the building off Malet Place.
  • The entrance area is clearly signed.
  • There is not a canopy or recess which provides weather protection at the entrance.
  • There is step-free access via a very easy slope at the entrance.
  • There is a key fob/card reader at a height of 112cm.
  • There are double automatic doors at this entrance.
  • The doors open by sliding.
  • The width of the opening is 168cm.
  • The doors have a low visual contrast.
  • The minimum width between the security barriers is 53cm.
  • The width of the wider security barrier is 88cm.
    The width of the door is 92cm.
    The door is single and opens towards you (pull).
    The height of the key card reader is 100cm.

Lift (Main)

  • The lift surveyed is located to the left from the main entrance.
  • The distance from the main entrance is 7m.
  • The most accessible route to the lift has step-free level access.
  • The ground, first, second, third, fourth, fifth, sixth, seventh and eighth floors are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have tactile markings and a high visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 90cm.
  • The internal dimensions of the lift are 152cm (width) x 138cm (depth).
  • The internal lift control buttons have tactile markings and a high visual contrast.
  • The majority of the internal controls are at a suitable height for a wheelchair user.
  • Internally the lift has: a mirror to aid reversing, a visual floor indicator and an audible announcer.
  • Lighting levels were low at the time of the survey.

Lift (Alternative)

  • The lift surveyed is located to the left from the main entrance.
  • The distance from the main entrance is 12m.
  • The most accessible route to the lift has a slight ramp or slope and manual doors.
  • The ground, first, second, third, fourth, fifth, sixth, seventh and eighth floors are accessed by this lift.
  • The lift door has a high visual contrast.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a medium visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 79cm.
  • The internal dimensions of the lift are 105cm (width) x 138cm (depth).
  • The internal lift control buttons have tactile markings, Braille markings and a medium visual contrast.
  • Some of the internal lift controls are at a suitable height for a wheelchair user.
  • Internally the lift has: a mirror to aid reversing and a visual floor indicator.
  • Lighting levels were low at the time of the survey.

Lift (Stair Lift - First Floor)

  • The lift surveyed is located on the first floor, to the left from the main lifts.
  • This lift is a stair lift.
  • The distance from the main lifts is 6m.
  • The most accessible route to the lift has step-free level access and manual doors.
  • The lift has a level manoeuvring space in front of it for a wheelchair user (150cm x 150cm).
  • The external lift control buttons have a low visual contrast.
  • All of the external lift controls are at a suitable height for a wheelchair user.
  • The lift door opening width is 80cm.
  • The internal dimensions of the lift are 80cm (width) x 120cm (depth).
  • The internal lift control buttons have a low visual contrast.
  • All of the internal lift controls are at a suitable height for a wheelchair user.
  • The lift is slow moving and the button needs to be pressed constantly when in use.
  • Internally the lift has: a separate door to exit.
  • Lighting levels vary due to the size of the space.
  • There are small level changes to access the lift.

Stairs (Main)

  • The stairs surveyed are located to the left from the main entrance.
  • There is a single manual door to access the stairwell.
  • -2, ground, first, second, third, fourth, fifth, sixth, seventh and eighth floors can be accessed by these stairs.
  • There are 20 steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The height of the steps is not between 15cm and 18cm.
  • The height of the highest step is 19cm.
  • The depth of the steps is not between 30cm and 45cm.
  • The steps have open risers.
  • Lighting levels vary due to the use of large glazed walls.

Stairs (Ground Floor to First Floor)

  • The stairs surveyed are located to the right from the main entrance.
  • The ground and first floors can be accessed by these stairs.
  • There are 20+ steps between floors.
  • The steps are clearly marked and have handrails on both sides.
  • The handrails are easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails do not extend horizontally beyond the first and last step.
  • The height of the steps is not between 15cm and 18cm.
  • The height of the highest step is 19cm.
  • The depth of the steps is not between 30cm and 45cm.
  • The steps have open risers.
  • Lighting levels vary due to the size of the space.

Parent and Baby Room / Feeding Room (Medical Room)

  • The room surveyed is located on the seventh floor.
  • The distance from the main lifts is 9m.
  • The most accessible route to the room has step-free level access.
  • There is step-free level access into the room.
  • There is pictorial and written text signage on or near the door.
  • The door opens outwards and has a high visual contrast.
  • The width of the door opening is 88cm.
  • Internally the door has a high visual contrast.
  • The height of the baby change facility when in use is 83cm.
  • There is a wash basin, a paper towel dispenser and a mirror in the room.
  • The wash basin has a push tap.
  • The room has a waste bin.
  • Seating available in the room includes: armchairs.
  • The walls and floor have a high visual contrast.
  • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Ground Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located to the right from the main entrance.
    • The distance from the main entrance is 9m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens inwards and has a high visual contrast.
    • The width of the door opening is 85cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 172cm (width) x 245cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 95cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a high visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a high visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 49cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 93cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 75cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rail is on the left as you face the wash basin.
    • The wash basin grab rail has a high visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 90cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 90cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There is one coat hook.
    • The coat hooks are 178cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were low at the time of the survey.

Toilet with Adaptations (First Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the first floor.
    • The distance from the main lifts is 9m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 80cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 153cm (width) x 196cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 80cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 45cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 94cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 77cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a medium visual contrast.
    • The soap dispenser is 92cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 86cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a sanitary bin.
    • There is one coat hook.
    • The coat hook is 131cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were low at the time of the survey.
    • The door has a locked leaf.

Toilet with Adaptations (Second Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the second floor.
    • The distance from the main lifts is 9m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 106cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 148cm (width) x 208cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 73cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 46cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a low visual contrast.
    • The toilet roll holder is 90cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 74cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 91cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 86cm from the floor.
    • There is no emergency alarm.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were uneven at the time of the survey, with pools of light and shade.

Toilet with Adaptations (Third Floor - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the third floor.
    • The distance from the main lifts is 9m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 88cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 148cm (width) x 208cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
    • The lateral transfer space is 73cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 44cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 92cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 71cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a medium visual contrast.
    • The soap dispenser is 96cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 87cm from the floor.
    • There is a pull cord emergency alarm within 10cm from the floor.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Fourth Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located along the fourth floor corridor.
    • The distance from the main lifts is 8m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 87cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 149cm (width) x 208cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 73cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 46cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 91cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 73cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a medium visual contrast.
    • The soap dispenser is 90cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 87cm from the floor.
    • There is a pull cord emergency alarm but it was tied up at the time of the survey.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were uneven at the time of the survey, with pools of light and shade.

Toilet with Adaptations (Fifth Floor - Right Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the fifth floor.
    • The distance from the main lifts is 8m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 86cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 149cm (width) x 208cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the right as you face the toilet, however it is obstructed.
    • The lateral transfer space is 73cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 46cm from the floor.
    • The toilet seat has a low visual contrast.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 94cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 72cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 95cm from the floor.
    • There is a wall mounted towel dispenser which cannot be reached when seated on the toilet.
    • The towel dispenser has a low visual contrast.
    • The towel dispenser is 121cm from the floor.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 87cm from the floor.
    • There is a pull cord emergency alarm but it was tied up at the time of the survey.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Sixth Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located on the sixth floor.
    • The distance from the main lifts is 8m.
    • The most accessible route to the toilet has step-free level access.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 87cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 149cm (width) x 209cm (depth) and there is not room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 73cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 46cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 90cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 74cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which can be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 94cm from the floor.
    • There is a wall mounted towel dispenser which cannot be reached when seated on the toilet.
    • The towel dispenser has a low visual contrast.
    • The towel dispenser is 120cm from the floor.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 87cm from the floor.
    • There is a pull cord emergency alarm but it was tied up at the time of the survey.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a waste bin and a sanitary bin.
    • There is one coat hook.
    • The coat hooks are 155cm from the floor.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.

Toilet with Adaptations (Eighth Floor - Left Hand Transfer)

  • Location and Access View
    • The toilet surveyed is located along the eighth floor corridor.
    • The distance from the main lifts is 8m.
    • The most accessible route to the toilet has step-free level access and automatic doors.
    • There is step-free level access into the facility.
    • There is pictorial signage on or near the door.
    • The door opens outwards and has a high visual contrast.
    • The width of the door opening is 105cm.
    • The door has a lever twist lock.
    • Internally the door has a high visual contrast.
    • There is a grab rail on the internal door with a high visual contrast.
  • Dimensions and Features View
    • The dimensions of the cubicle are 150cm (width) x 208cm (depth) and there is room for a wheelchair user to manoeuvre (150cm x 150cm).
    • There is a lateral transfer space to the left as you face the toilet, however it is obstructed.
    • The lateral transfer space is 73cm (from the side of the toilet pan).
    • There is a lever flush on the transfer side.
    • There is a horizontal grab rail on the non-transfer side.
    • The horizontal grab rail has a low visual contrast.
    • There is a vertical grab rail on the transfer side.
    • The vertical grab rail has a low visual contrast.
    • There is a dropdown rail on the transfer side.
    • The dropdown rail has a low visual contrast.
    • The toilet seat is 45cm from the floor.
    • The toilet seat has a low visual contrast.
    • The toilet has a padded backrest.
    • There is a wall mounted toilet roll holder which can be reached when seated on the toilet.
    • The toilet roll holder has a medium visual contrast.
    • The toilet roll holder is 90cm from the floor.
    • The wash basin and taps can be reached when seated on the toilet.
    • The wash basin is 73cm from the floor.
    • The wash basin has a lever mixer tap.
    • The vertical grab rails are on both sides of the wash basin.
    • The wash basin grab rails have a low visual contrast.
    • There is a wall mounted soap dispenser which cannot be reached when seated on the toilet.
    • The soap dispenser has a low visual contrast.
    • The soap dispenser is 93cm from the floor.
    • There is not a towel dispenser.
    • There is a wall mounted hand dryer.
    • The hand dryer has a low visual contrast.
    • The hand dryer is 86cm from the floor.
    • There is a pull cord emergency alarm, however it is not within 10cm from the floor.
    • There is a full length mirror.
    • There is no shelf.
    • The cubicle has a sanitary bin.
    • There are no coat hooks.
    • The walls and floor have a high visual contrast.
    • Lighting levels were even at the time of the survey.