Platforms (1-7)

  • The platform is flat throughout its length.
  • Platform Information View
    • Access to the train is via: portable ramp.
    • There are tactile markings along the platform edge, throughout its length.
    • The edge of the platform is clearly marked.
    • There are digital display(s) for train times on this platform.
    • Signage on this platform includes; directional to other platforms, directional to lifts and directional to way out.
    • Announcements on this platform are audio and visual.
    • A member of staff is available to provide assistance.
    • There are some sheltered areas on the platform(s).
    • There is fixed bench seating with armrests on this platform.
    • The height of the seating is 46cm.
    • The width of the majority of seats is 56cm.
    • Perch seating is available on this platform.
    • There are hearing loops fitted to the platforms.
    • There is step-free access from the platform(s), via lift, to the exit concourse.

Toilet with Adaptations (Platform 1 and 2 - Right Hand Transfer)

  • This toilet is located at the north end (London end) of Platform 1 and 2.
  • There is step-free level access into the toilet.
  • There is Braille, tactile, pictorial and written text signage on or near the door.
  • The door to enter opens outwards and has a high colour contrast with the surrounding walls.
  • The width of the toilet door opening is 95cm.
  • Internally the door has a high colour contrast.
  • There is a grab rail on the internal door with a high colour contrast.
  • The dimensions of the cubicle are 224cm x 185cm and it does not have a 150cm x 150cm turning space.
  • There is a lateral transfer space to the right of the seat but it is obstructed.
  • The lateral transfer space is 130cm (from the side of the toilet pan to the wall).
  • There is a spatula flush on the transfer side.
  • There is a horizontal grab rail on the non transfer side.
  • The horizontal grab rail has a low colour contrast with the surrounding walls.
  • There is a vertical grab rail on the transfer side.
  • The vertical grab rail has a low colour contrast with the surrounding walls.
  • There is a dropdown rail on the transfer side.
  • The dropdown rail has a low colour contrast with the surrounding walls.
  • The toilet seat is 47cm from the floor.
  • The toilet seat has a low colour contrast.
  • The toilet does not have a padded backrest.
  • There is a wall mounted toilet roll holder which cannot be reached when seated on the toilet.
  • The toilet roll holder has a low colour contrast.
  • The toilet roll holder is 91cm from the floor.
  • The wash basin and taps can be reached when seated on the toilet.
  • The wash basin is 72cm from the floor.
  • The wash basin tap type is lever mixer.
  • The vertical grab rails are on both sides of the wash basin.
  • The vertical grab rails have a low colour contrast with the surrounding walls.
  • There is a wall mounted soap dispenser which cannot be reached when seated on the toilet.
  • The soap dispenser has a low colour contrast.
  • The soap dispenser is 90cm from the floor.
  • There is not a towel dispenser.
  • There is a wall mounted hand dryer.
  • The hand dryer has a low colour contrast.
  • The hand dryer is 100cm from the floor.
  • There is a pull cord emergency alarm at a recommended height (within 10cm from the floor).
  • There is a full length mirror.
  • There is an unobstructed shelf.
  • The shelf does not meet the AccessAble criteria for Stoma Friendly Toilets.
  • The cubicle has a sanitary bin.
  • There are no coat hooks.
  • There is a high colour contrast between the walls and floor.
  • Lighting levels are moderate to good.

Parent and Baby Room / Baby Feeding Room (Platform 1 and 2)

  • There is step-free level access into the room.
  • The door to enter opens outwards and has a high colour contrast with the surrounding walls.
  • The width of the door opening is 95cm.
  • Internally the door has a high colour contrast.
  • The baby change facility when in use is at a height of 95cm from the floor.
  • The wash basin tap type is lever mixer.
  • There are no seats available in this room.
  • There is not a toilet in the parent and baby room.
  • The room has a waste bin .

Stairs (Platforms to Concourse)

  • The floors which are accessible by stairs are Platforms to Concourse.
  • There are more than 20 steps, which are clearly marked, with handrails on both sides.
  • The handrails are easy to grip.
  • The handrails cover the flight of stairs throughout its length.
  • The handrails extend horizontally beyond the first and last step.
  • Steps are split with a resting area.
  • The height of the highest step is 16cm.
  • Lighting levels are moderate to good.

Escalator (Platforms to Concourse)

  • The escalator is located along the platform.
  • The floors which are accessible by escalator are Platforms to Concourse.
  • The escalator only goes up.
  • The escalator steps are clearly marked.
  • The foot (bottom) and head (top) of the escalator are clearly marked.
  • Lighting levels are moderate to good.

Lift (Platforms to Concourse)

  • The lift is located along the Platform.
  • The floors which are accessible by the lift surveyed are Platforms 5-6-7 to Concourse.
  • The lift does have a recommended turning space (150cm x 150cm) in front of it.
  • The lift door has a high contrast.
  • The external lift control buttons have tactile markings, Braille markings and a high colour contrast.
  • All of the external lift controls are at the recommended height (between 90cm - 120cm).
  • The lift door opening width is 160cm.
  • The internal dimensions of the lift are 205cm x 290cm.
  • The internal lift control buttons have tactile markings and a high colour contrast.
  • All of the internal lift controls are at the recommended height (between 90cm - 120cm).
  • Internally the lift has: a separate door to exit, a visual floor indicator, an audible announcer and a list of floor services/facilities.
  • Lighting levels are moderate to good.
  • There are other lifts which vary in size at the same location.
  • There are similar lifts to and from all platforms for both concourses.

Concourse

  • Access View
    • There is step-free access to the concourse, via lift, from Platforms 1-7.
  • Maps and Signage View
    • There are digital display(s) for train times in this concourse area.
    • Wayfinding signage in this concourse area includes; directional to exits and directional to platforms.
    • Wayfinding signage is positioned; overhead, on walls and on posts.
  • Seating Area(s) View
    • The seating areas are located throughout the concourse.
    • There is step-free access to the seating area.
    • There is sufficient space for a wheelchair user to use the seating area.
    • There is space for an assistance dog to rest within the seating area.
    • There is are; fixed rows of individual seats with and without armrests.
    • The height of the seating is 52cm.
    • The width of the majority of seats is 56cm.
  • Other Features and Facilities View
    • A member of staff is available to provide assistance.
    • Announcements in this concourse area are audio and visual.
    • The type of flooring in this area is vinyl.
    • There is some flooring which is shiny and could cause issues with glare or look slippery to some people.
    • The colour contrast between the walls and floor in this concourse area is high.
    • The lighting levels are moderate to good.

Ticket Barriers

  • The width of the standard barriers is 65cm.
  • The ticket slot heights for the standard barriers are 90cm (insert ticket) and 100cm (remove ticket).
  • The contactless card reader height is 100cm for the standard barriers.
  • The barcode scanner height is 80cm for the standard barriers.
  • The width of the wider access barriers is 87cm.
  • The barriers have ramped thresholds.
  • The ticket slot heights for the wider access barriers are 90cm (insert ticket) and 100cm (remove ticket).
  • The contactless card reader height is 100cm for the wider access barriers.
  • The barcode scanner height is 80cm for the wider barriers.
  • Staff are available to provide assistance at the barriers.

Exit (Station to Gatwick Airport)

  • This exit is located after the ticket barriers.
  • There is step-free level access at the exit.
  • There are double automatic doors which opens away from you.
  • The width of the opening is 140cm.

Related Access Guides (Gatwick Airport)